NO-AE Nitric Oxide Sensor (NO Sensor) Description
Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology.
NO-AENitric Oxide Sensor size:
20mm diameter, the industry standard size for portable gas detectors
The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers.
Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes.
The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.
NO-AE Nitric Oxide Sensor (NO Sensor) Specification
* Range: 5,000ppm NO limit of performance warranty
* Sensitivity: 40 to 80nA/ppm in 250ppm NO
* Resolution: < 1 RMS noise (ppm equivalent)
* Response time t90: < 75s from zero to 250ppm NO
* Temperature range: -30 to +50'C
* Pressure range: 80 to 120 kPa
* Humidity range: 15 to 90 % rh continuous
* Weight: < 6 g
Matched Transmitter board for NO-AE NO Sensor
4-20mA Digital Transmitter Board
* Factory calibration, custom-set for immediate use
* Digital zero, sensitivity and temperature compensation
* Digital and 4-20mA output
* Biased or unbiased operation
* Calibration and range change
SO2-AE Sulfur Dioxide Sensor SO2 Sensor Description Alphasense Sulfur Dioxide gas sensors operate using proven fuel cell technology. SO2-AE Sulfur Dioxide Sensor sizes: 20mm diameter, the industry standard size for portable gas detectors The SO2 range provides OEMs with reliable sensors for use in a variety of applications. Strong signal levels combined with low zero current allows resolution below 1ppm and an operating range for safety applications up to 2,000ppm. The sensors are designed for use in both fixed site and portable instrumentation. The SO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. SO2-AE Sulfur Dioxide Sensor SO2 Sensor Specifications * Range: 2,000ppm limit of performance warranty * Sensitivity: 55 to 80nA/ppm in 400ppm SO2 * Response time t90: < 30s from zero to 400ppm SO2 * Resolution: < 1.5 RMS noise (ppm equivalent) * Temperature range: -30 to 50'C * Pressure range: 80 to 120 kPa * Humidity range:15 to 90 % rh continuous * Weight: < 6 g
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
NO-B1 Nitric Oxide Sensor (NO Sensor) Description Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology. NO-B1 Nitric Oxide Sensor size: 32mm diameter package, the best choice for fixed site applications The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers. Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes. The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. NO-B1 Nitric Oxide Sensor (NO Sensor) Specification * Range: 250ppm NO limit of performance warranty * Sensitivity: 400 to 620nA/ppm in 50ppm NO * Resolution: < 0.15 RMS noise (ppm equivalent) * Response time t90: < 30s from zero to 50ppm NO * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 13g
Supplier: All type clothes, urea, all type agriculture and food items, all personal and entertainment items, all industrial and automotive items, all construction household and furnishing, all computers electronics and electrical, handicraft, items, npk, fertilizers t shirt, blanket,dry fruits, animal feeds, towel, bedsheets, toys, all grocery, copper wire scrap, copper ore concentrate, zinc ore concentrate, lead concentrate, fly ash, a4 paper, a3 paper, craft paper, occ, ldpe, hdpe , pvc resin, petroleum products, jp54, jet a1, crude oil, blco , biodiesel, diesel, fuel, coal, d2, petcock, pulses, mustard oil, spices , sanitizer, gloves, medical products, cement, core sand, old ships lng, lpg, all groceries items, food products, hms1 and hms2, fish, chicken feet, chicken paws, agri & food processing agriculture products, fertilizers, seeds, farm products grains, fruits, vegetables, river sands, aggregates, pvc electrical wire, rice, charcoal, wheat flour
Services: Export, import, merchant export import
Buyer: All metals, minerals, petroleum products, food products and paper products
Supplier: Wired magnetic door sensors.
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Supplier: Low voltage power cables, mid voltage power cables, control cables, instrumentation and telecommunication cables, optical fiber cables, mine low voltage power cables, mine mid voltage power cables, rail transit communication cables, railway rolling stock cables, cables for use in photovoltaic systems, fireproof cable, low voltage power cables for shipboard and offshore, mid voltage cables for shipboard and offshore, control cables for shipboard and offshore, instrumentation and telecommunication cables for shipboard and offshore compensating extension cables and compensating cables, rubber sheathed cable, charging post cable, connecting cables for equipment, towline cables, high temperature resistant cable,esp power cable, (electrical submersible pump power cable), mining detection cable, logging cable, submarine power cable
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)