NH3-A1 Ammonia Sensor NH3 Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Ammonia (NH3)
Our first family of Ammonia sensors. This sensor is designed for higher concentrations of Ammonia. Sensors for lower level detection are in development.
NH3-A1 Ammonia Sensor NH3 Sensor Specifications
* Range: 200 ppm NH3 limit of performance warranty
* Sensitivity: 17 to 27 nA/ppm in 50ppm NH3
* Response time t90:
NH3 3E 100 Ammonia Sensor (NH3 Sensor) FEATURES * Amperometric 3 electrode sensor cell * Fixed organic gel electrolyte * No CO2 interference * 0 volt bias operation NH3 3E 100 Ammonia Sensor (NH3 Sensor) TYPICAL APPLICATIONS * TLV-monitoring, leakage detection * Fixed point applications in cold storages & refrigeration plants only * For other applications please use NH3 3E SE versions * No background concentrations of ammonia & alcohols NH3 3E 100 Ammonia Sensor (NH3 Sensor) TECHNICAL SPECIFICATIONS * Measuring Range: 0-100 ppm * Sensitivity Range: 90 nA/ppm ± 40 nA/ppm * Zero Current at 20 deg C: < ± 150 nA * Resolution at 20 deg C: < 2 ppm * Bias Potential: 0 mV * Linearity:
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
4-20 mA/0-5v/0-10v Output NH3 ammonia sensor Product Description Our NH3 sensor uses the electrochemical principle to detect the concentration of ammonia (NH3). The reaction is rapid, sensitive, low-power, high-precision, anti-interference, and has excellent repeatability and stability. This product is widely used in the detection of ammonia in industrial, mining and environmental protection. Analog signal output, 4~20mA, 0~5V, 0~10V optional, equipment 10~30V wide voltage supply. The enclosure rating is high and can be adapted to different environmental monitoring. Power supply 10~30V DC output signal 4~20mA0~5V0~10V Power consumption 0~50ppm accuracy (high precision) 0.25W 0~100ppm accuracy (high precision) 0.25W 0~500ppm 1W Operating temperature -20~+50 Working humidity 15%RH~90%RH Pressure range Standard atmospheric pressure ±10% Stability (months) ï¼?10% Response time 150S Zero drift (-20~40C) -3~10ppm (0~100ppm products) Repeatability 10%output value Service life 24 months Precision 0~50ppm accuracy (high precision) ±10%FS 0~100ppm accuracy (high precision) ±10%FS 0~500ppm ±20%FS±10ppm Oxygen content: 18% Resolution 0~50ppm model: 0.01ppm 0~100ppm model: 1ppm 0~500ppmmodel1ppm Detailed Images 1. High-sensitivity gas detection probe, stable signal, accurate measurement of NH3 concentration (PPM), high accuracy. 2.Avariety of measurement ranges, 0~50PPM, 0~100PPM, 0~500PPM. 3.Avariety of analog signal output options: 4~20mA, 0~5V, 0~10V. 4. The product adopts wall-mounted waterproof shell, which is easy to install and has high protection level. . Installation Instructions No output or output error possible reason: 1) The range corresponding error causes the PLC to calculate an error. 2) The wiring method is incorrect or the wiring sequence is wrong. 3) The power supply voltage is incorrect (24V power supply for 0~10V models). 4) The distance between the transmitter and the collector is too long, causing signal disturbance. 5) The PLC collection port is damaged. 6) Equipment damage. Notes 1) The aging test before use is not less than 48 hours; 2) Electrolyte leakage will cause injury, please do not disassemble the sensor at will; 3) The sensor should avoid contact with organic solvents, paints, chemicals, oils and high-concentration gases; 4) The sensor should not be immersed in an oxygen-free environment for a long time, otherwise it will damage the performance of the sensor; 5) It should not be used for a long time in an environment containing corrosive gases, corrosive gases will damage the sensor; 6) It is forbidden to store and use in high concentration alkaline gas for a long time; 7) The air inlet holes must not be blocked or contaminated. Our Services & Strength 1.OEM servie, we can design as your requirements. 2.2 years warranty for our sensors 3.We have CE,FCC,ISO,ROHS certificates. 4.We have sensor in stock, can delivery immediately.
Ar8500 ammonia gas detector product description: Ammonia analyzer is a continuous quantitative analysis of formaldehyde concentration apparatus, the apparatus using imported high precision electrochemical principle formaldehyde sensor, fast response speed, high precision, of its stability, good repeatability. The apparatus is widely used in metallurgy, power plant, farms, mines, chemical, scientific research, medical, pharmaceutical, environmental protection and other fields. Ammonia concentration detector, gas detector, gas leak detector Characteristics of the instrument: * adopt imported abroad electrochemical sensor * big screen for multiple parameters of lcd backlight display, visual display unit, gas concentration, working state * the two grade dual alarm settings, the outstanding audio sound alarm, voice of up to 80 db * the service life of the sensor: 2 years(it can be replaced) * power supply: 3 x 1.5v aa battery * battery service life: about 100 hours of continuous use (when the backlight is off). * size: 182*66*32(mm) Ar8500 ammonia gas detector application: * farms, animal farm ammonia detection; * ambient air monitoring and evaluation, * landfill ammonia detection; * frozen field ammonia concentration; * dangerous space into the detection; * shop and workshop etc and the surrounding places ammonia detection; * after decorating the house ammonia detection; * storage tanks, pipelines, valves, leakage detection; * waste field survey Ar8500 ammonia gas detector technical parameters * detection of gas: ammonia ( nh3 ) * measuring range: 0~100ppmâ?? * resolution: 0.1ppm * basic error: 0.5ppm * response time: less than 120 seconds * recovery time: less than 120 seconds * repeatability: less than â± 1% * battery: 3 x 1.5v aa batteryâ??
Supplier: All type clothes, urea, all type agriculture and food items, all personal and entertainment items, all industrial and automotive items, all construction household and furnishing, all computers electronics and electrical, handicraft, items, npk, fertilizers t shirt, blanket,dry fruits, animal feeds, towel, bedsheets, toys, all grocery, copper wire scrap, copper ore concentrate, zinc ore concentrate, lead concentrate, fly ash, a4 paper, a3 paper, craft paper, occ, ldpe, hdpe , pvc resin, petroleum products, jp54, jet a1, crude oil, blco , biodiesel, diesel, fuel, coal, d2, petcock, pulses, mustard oil, spices , sanitizer, gloves, medical products, cement, core sand, old ships lng, lpg, all groceries items, food products, hms1 and hms2, fish, chicken feet, chicken paws, agri & food processing agriculture products, fertilizers, seeds, farm products grains, fruits, vegetables, river sands, aggregates, pvc electrical wire, rice, charcoal, wheat flour
Services: Export, import, merchant export import
Buyer: All metals, minerals, petroleum products, food products and paper products
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
CL2-A1 Chlorine Sensor (CL2 Sensor) Description Alphasense Chlorine gas sensors operate using proven fuel cell technology. CL2-A1 Chlorine Sensor size: 20mm diameter, the industry standard size for portable gas detectors The Cl2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 20ppb and an operating range from +0 to 20ppm. The sensors are suitable for inclusion in fixed installation sensing heads and portable safety instruments. These sensors have improved transient response to humidity changes compared to competitors' equivalent sensors. The Cl2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. CL2-A1 Chlorine Sensor (CL2 Sensor) Specifications * Range: 20 ppm limit of performance warranty * Sensitivity: -350 to -750 nA/ppm in 10ppm Cl2 * Response time t90: < 60s from zero to 10ppm Cl2 * Resolution: < 0.02 RMS noise * Operating life: > 24 months * Temperature range: -20 to 50'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 %rh continuous * Weight: < 6 g
NO2-A1 Nitrogen Dioxide Sensor (NO2 Sensor) Description Alphasense Nitrogen Dioxide gas sensors operate using proven fuel cell technology. NO2-A1 Nitrogen Dioxide Sensor size: 20mm diameter, the industry standard size for portable gas detectors The NO2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 50 parts per billion (ppb) and an operating range to 20ppm. The sensors are suitable for use in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers. The NO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. NO2-A1 Nitrogen Dioxide Sensor (NO2 Sensor) Specifications * Range: 20 ppm NO2 limit of performance warranty * Sensitivity: -250 to -650 nA/ppm in 10ppm NO2 * Response time t90: < 50 (s) from zero to 10ppm NO2 * Resolution: < 0.02 RMS noise (ppm equivalent) * Temperature range : -20 to 50 deg C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6 g
ETO-A1 Ethylene Oxide Sensor ETO Sensor Description Alphasense is expanding its line of Electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ethylene Oxide (C2H4O) The ETO is a general purpose sensor, primarily developed for monitoring Ethylene Oxide but also capable of measuring other volatile organic compounds (VOCs). Our toxic evaluation board allows easy adjustment of the bias voltage to optimise this sensor for the required application. See application note AAN113. Available in A and B series ETO-A1 Ethylene Oxide Sensor ETO Sensor Specifications * Range: 100 ppm EtO limit of performance warranty * Sensitivity: 2000 to 3200 nA/ppm in 20ppm EtO * Response time t90: < 150s from zero to 20ppm EtO * Resolution: < 0.1 RMS noise (ppm equivalent) * Temperature range: -30 to 50'C * Pressure range: 80 to 120kPa * Humidity range: 15 to 90% rh continuous * Weight: < 6 g