Winner2000ZDE is an intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use. 1.Main Specifications: Model Name Winner2000ZDE Standard ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 Principle MIE scattering principle Measuring Range 0.1-300μm Channels Number 39 Accuracy 25000hour Wet Dispersion Method Ultrasonic Frequency:40KHz Power:35W, Time: �1S Stir Revolutions Speed: 0-3000RPM (Adjustable) Circulate Rated Flow:8L/min Rated Power:10W Sample Pool Volume:350mL Sample cuvette Volume: 10mL ( Available) Operation Mode Full automatic and manual control, freely choose Output parameter D10,D50,D90,D100,S/V referent parameters Optical Calibration System Full automatic Test Speed
Product Description Winner3008B is intelligent dry laser particle size analyzer, manual and full automatic operation model. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy. It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. Itâ??s fit for any dry powder materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, Itâ??s with the same accuracy and repeatability. Main Features (1) Advanced testing optical path. Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range. (2)Scientific dispersion system Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion systemâ??s working life. (3)Human-based operation mode Manual and Full automatic, easy choose. (4)High precision-automatic optical path calibration system Itâ??s composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state. (5)Intelligent data analysis-winner unique software support Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output. (6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter). (7)Users can design the test report output and display forms according to industry requirements. Specification Model Winner3008B Standard ISO 13320-1:1999ï¼?GB/T19077.1-2308ï¼?Q/0100JWN001-2013 Measuring Range 0.1-2000�¼m/0.1-1200�¼m Channels Number 100/97pcs Accuracy
Scope FDQ-0301 laser particle size analyzer based on physics Fraunhofer diffraction and Mie scattering theory basis. This theory can be simply understood as: travels in straight lines parallel laser beam blocking particles encountered in the communication process, the phenomenon of diffraction and scattering, and small angle light scattering large particles, small particles of light scattering angle is large. Figure 1-1 shows the diffraction pattern formed by individual particles, the larger the particle diameter, the smaller the center of the bright ring, the smaller the particle diameter, the larger the center of the bright ring. Use photo detector array receiving light at different angles, for the corresponding angle, its energy is set corresponding to the diameter of the particles occurs diffraction (scattering) caused by the respective other angle light will reflect the strength of the corresponding diameter of the particles throughout the assembly of particles occupies proportion, according to the intensity of the received scattered light at different angles, you can perform anti-particle distribution of the sample between the relative content and various size fractions. Features 1. Up to 82 sampling channels to improve the resolution of the test results; all the photovoltaic device fabricated on a single silicon chip, to ensure the life of the photovoltaic array; cross-sector arrangement, increasing the light receiving area, improves the sensitivity ; 2. micro injection method, using a peristaltic pump automatic loop injection mode, using siphon pump automatic cycle injection mode, to meet different customer test requirements, the instrument comes standard MS-01 micro-injector device; 3. The single lens full scale measurements, all optical components are mounted on reinforced base before fastening a good optical system is shipped, the instrument more stable performance; 4. Imported semiconductor lasers, has a long life, stable optical parameters, not afraid of vibration and a series of advantages, continuous working time of up to 24 hours, to meet user requirements for large continuous load test. Technical Parameters 1, the test range (um): 0.15-400; (0.4-1100,0.1-450,0.25-650, 0.4-1100) 2. Repeatability:
Principle of operation The QT-1 laser particle size analyzer uses Mie scattering theory to measure particle size, considering the refractive index of the particles and dispersion medium. According to Mies theory, a particle will scatter light at an angle determined by that particles size. A collection of particles will produce a pattern of scattered light defined by intensity and angle that can be transformed into a particle size distribution result. The data of particle test can be calculated in two ways: unconstrained fitting inversion and constrained fitting inversion. The constrained fitting inversion is a relatively simple way. The particle size distribution is inverted with the assumption that there is a certain distribution pattern in particles. However, the deviation exists between the assumption and the reality. Therefore, the tested results through the constrained fitting inversion cannot truly reflect the real size distribution of the particles. In unconstrained fitting inversion, no distribution pattern of particles is assumed before the test, and the size distribution of the particles is directly and precisely calculated from the light intensity. In this way, the instrument requires reasonable sensor design and size grading to ensure its high performance. The particle size distribution can be precisely calculated with QT-1 Laser particle size analyzer which uses the optimized non-uniform cross 3D fan-shaped sensor array and the reasonable size grading.
Product Description Winner2008A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field. Specification Model Name Winner2008A Standard ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 Principle MIE scattering principle Measuring Range 0.01�¼m-2000�¼m Channels Number 127 Accuracy error â?¤0.5% (Deviation of D50 on national standard sample) Repeatability error â?¤0.5% (Deviation of D50 on national standard sample ) Light source High performance He-Ne Laser (�»= 632.8nm, P>2MW) Lifetime>25000hours Dispersion Method Ultrasonic Frequency:40KHz Power:35W, Time: â?¥1S ,Anti-dry function Stir Revolutions Speed: 0-3000RPM (Adjustable) Circulate Rated Flow:8L/min Rated Power:10W Sample Pool Volume:350mL Micro- Sample Pool Volume: 10mL ( Available) Operation Mode Full automatic/ manual control, freely choose Resolution Free distribution truly reflect particle size distribution Optical bench alignment system Japan Canon lens, Full automatic,precision is up to 0.1um Software function Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Statistic Method Volume Distribution, Quantity Distribution Statistic Comparison Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. User-defined Analysis Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries Test Report Word, Excel,Photo( Bmp), Text etc Multiple-language Support Multiple language Support Intelligent operation Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor Testing speed
Product Description Winner2006A intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01m to 100m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data. It enables you understand materials well, such as abrasives,adhesives, agrochemical,barite, Batteries, Bentonite, Main Features (1) The laser particle size analyzer adopts a unique concentrated Fourier transform optical path. In order to better test sub-micron particles, it adopts the patented technology of orthogonal dual laser beams, and the measurement range is extended from 0.01/0.1�¼m-1000�¼m. (2) The intelligent operation mode realizes one-click testing, automatic water replenishment, ultrasonic dispersion, circulation, and drainage, which not only reduces the workload, but also achieves better repeatability after eliminating human factor errors. (3) The laser particle size analyzer adopts an automatic optical alignment system composed of a precision four-phase hybrid stepper motor. Its micro-movement accuracy reaches the micron level, so that the optical path is always in good condition. (4) Laser particle size analyzer configuration Liquid sample dispersion/preparation system: fully built-in mechanical stirring, ultrasonic dispersion, and circulation paths are integrated, and the high-power circulation pump and pipeline are optimized to effectively prevent the precipitation of large particles. (5) Software support: Original patented unconstrained free fitting technology enables particle analysis without any functional restrictions and truly reflects particle distribution. (6) Output parameters: (D50, D03, D06, D10, D16, D25, D75, D84, D90, D97, D98, set any value, S/V, D[3,2], D[4,3 ] ) Specification Model Name Winner2006A Standard ISO13320-1:1999,GB/T19077.1-2008ï¼?Q/0100JWN001-2013 Principle MIE scattering theory Size range 0.o1m-1000m Detector Channels 90pcs Accuracy error
Specification Model Name Winner2018 Standard ISO13320:2016, GB/T19077.1-2016, Q/0100JWN001-2013 Principle Laser diffraction principle Analysis MIE scattering theory Measuring Range 0.1�¼m-450�¼m Channels Number 40 PCS Accuracy error 25000hour Dispersion Method Ultrasonic Frequency:40KHz Power:60W, Time: â?¥1S Stir Revolutions Speed: 0-3000RPM (Adjustable) Circulate Rated Flow:8L/min Rated Power:10W Sample Pool Volume:350mL Micro- Sample Pool Volume: 10mL ( Available) Operation Mode Full automatic and manual control, freely choose Output parameter D10,D50,D90,D100,S/V referent parameters Optical alignment system Full automatic Test Speed
Product Description Winner2008B full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Product Description Winner2008Awet laser particle size analyzer measure size is from 0.01 to 1200 micron, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multi-spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field. Parameter Model Name Winner2008A Standard ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 Principle MIE scattering principle Measuring Range 0.01�?�¼m-2000�?�¼m 0.01�?�¼m-1200�?�¼m Channels Number 127 Accuracy error 25000hours Dispersion Method Ultrasonic Frequency:40KHz Power:35W, Time: �¢?�¥1S ,Anti-dry function Stir Revolutions Speed: 0-3000RPM (Adjustable) Circulate Rated Flow:8L/min Rated Power:10W Sample Pool Volume:350mL Micro- Sample Pool Volume: 10mL ( Available) Operation Mode Full automatic/ manual control, freely choose Resolution Free distribution truly reflect particle size distribution Optical bench alignment system Japan Canon lens, Full automatic,precision is up to 0.1um Software function Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Statistic Method Volume Distribution, Quantity Distribution Statistic Comparison Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. User-defined Analysis Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries Test Report Word, Excel,Photo( Bmp), Text etc Multiple-language Support Multiple language Support Intelligent operation Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor Testing speed
Product Description Winner3008A is intelligent dry laser particle size analyzer, manual and full automatic operation model. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy. It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It's with the same accuracy and repeatability. Specification Model Winner3008A Standard ISO 13320-1:1999 GB/T19077.1-2308Q/0100JWN001-2013 Measuring Range 0.1-2000m/0.1-1200m Channels Number 100/97pcs Accuracy
Product Description Winner3003 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results. Specification Model Name Winner3003 Size Range 0.1�?�¼m-300�?�¼m Standard ISO13320-1:1999 GB/T19077.1-2008 Q/0100JWN001-2013 Channels Number 40 pcs Accuracy error
Winner2000ZDE intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.
Winner2309A is intelligent full automatic laser particle size analyzer, adopt the most advanced International MIE scattering principle and Fraunhofer diffraction principle, which is integrated model of wet and dry dispersion system, High sensitive and High-resolution photoelectric probe system and imported Canon lens optical path ensure the good accuracy and repeatability of particle size distribution, It s widely used in industrial production quality control departments and research institutions. Test range:0.01-2000 microns
Product Description Winner2005B intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01/0.1�¼m to 1000�¼m. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data,built-in side wide-angle detector, make sure get 0.01 micron particles scattering angles. Specification Model Name Winner2005B Standard ISO13320-1:1999ï¼?GB/T19077.1-2008ï¼?Q/0100JWN001-2013 Principle MIE Scattering Principle Size range 0.1�¼m-1000�¼m Photodetectos 87 pcs Accuracy â?¤0.5% (Deviation of D50 on national standard sample) Repeatability â?¤0.5% (Deviation of D50 on national standard sample) Laser Semi conductor Laser �»= 636.5nm, p>2mW Service time>25000 hour Wet dispersion Ultrasonic Frequency:40KHz Power:35W, Time: â?¥1S Agitator Revolutions Speed: 0-3000RPM (Adjustable) Circulation Rated Flow:8L/min Rated Power:10W Sample tank Volume: 350mL Operation mode Manual and Full automatic Optical alignment system Full automatic optical path alignment system Software function Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Statistic Method Volume Distribution, Quantity Distribution Statistic Comparison Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. User-defined Analysis Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries Test Report Word, Excel,Photo( Bmp), Text etc Multiple-language Support Multiple language Support Intelligent operation Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor Report Items Particle size distribution table&graph, average diameter, Median diameter, SSA, etc. Testing speed
Product Description Winner3006 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results. This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.
Product Description Winner2308A intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.1m/0.01m to 1200�¼m/2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It's the prior choice for industrial production quality control departments and research institutions.
Product Description Winner2009A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01�¼m to 2000�¼m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Product Description Winner3009A intelligent dry laser particle size analyzer, manual and full automatic operation modes. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy. It uses air as dispersion medium, and uses turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder materials,especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It's with the same accuracy and repeatability. Main Features (1) Advanced testing optical path. Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range. (2)Scientific dispersion system Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system's working life. (3)Human-based operation mode Manual and Full automatic, easy choose. (4)High precision-automatic optical path calibration system It's composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state. (5)Intelligent data analysis-winner unique software support Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output. (6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter). (7)Users can design the test report output and display forms according to industry requirements. Specification Model Winner3009A Standard ISO 13320-1:1999 GB/T19077.1-2308 Q/0100JWN001-2013 Measuring Range 0.1-2000m Channels Number 100 pcs Accuracy
Winner311PRO is a new generation desktop spray particle size analyzer designed and developed mainly for droplet particle size testing of small spray equipment. Based on Winner311XP, it incorporates more unique micro-nano technologies, innovative design of external automatic mobile platform, optical path The design is more optimized, the detection channels are wider distributed, the algorithm is more stable, and the application is more intelligent. Winner311PRO can perform non-contact particle size measurement of droplets, liquid droplets, smoke, aerosol, powder mist, etc. dispersed in the air, and meets the requirements for particle size testing of inhaled aerosols, sprays, powder mist, etc. specified in the National Pharmacopoeia. , filling the gap of domestic laser particle size analyzer in measuring droplet size of small atomization devices.
Winner2308B intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.1m/0.01m to 1200m/2000m, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It's the prior choice for industrial production quality control departments and research institutions.