Applicable environment a) Ambient temperature: -5~+40; b) Relatively moderate: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the frame frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Rated voltage: DC 24V, voltage fluctuation range 24X (1±10%V; f) Working position: horizontal; g) There is no harmful gas causing explosion hazard around, and good dust-proof measures should be applied. Mechanical properties 1614998643577125.jpg Precautions a) The identification pin numbers of the programmable time relays are the same. Please confirm the corresponding slow suction time of the corresponding type of relay before use. b) Terminals 1, 2, 3, and 4 of the two coils of the relay are directly connected in parallel with the two diodes on the printed circuit; therefore, when measuring the electrical characteristics of the relay, the positive pole of the power supply must be connected to the terminals 1, 3, and the negative pole of the power supply must be connected to the terminals 1, 3. On terminals 2, 4. C) Contacts 11 and 12 are already occupied by the relay, and the number of contacts that can be used by the user is 2QH, 1Q. d) The position of the relay contact system is shown in Figure 1. When in use, the socket must be equipped with an identification pin. e) The use environment of the relay should have good ventilation conditions and dust-proof equipment. And used in specially designed circuits; in special circumstances, the electrical characteristics and contact capacity of the relay should be considered to ensure the reliable operation of the relay.
Product Usage Programmable time relays include JSBXC-780, JSBXC-820, JSBXC-820, JSBXC1-850, and JSBXC1-870 series relays. Each type of relay has four types of warm-up time to choose from, among which JSBXC1-870 series The heating time can also be changed according to the special requirements of users. The relay is used as a delay control in the circuit. Applicable environment a) Ambient temperature: -5~+40; b) Relatively moderate: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the frame rate is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Rated voltage: DC 24V, voltage fluctuation range 24X (1�±10%) V; f) Working position: horizontal; g) There is no harmful gas causing explosion hazard around, and good dust-proof measures should be applied. Mechanical properties 1614996944256898.jpg Electrical characteristics .jpg Note: The error range of the resistance value of the relay coil is ±(nominal resistance value10%) Time characteristics
Time relay can be widely used in machines and equipment needing self-control of high precision and reliability. It is characteristic of small size, light weight, compact structure, high dependable and efficient,long life,etc.
Features 1.Intelligent and digital led timer 2.1~4 channels, programmable and arbitrary combination and arbitrary output 3.Memory storage (10years) / mechanical life 4.Wide timing range (1millsecond~9999days) 5.Power supply (220v ac 50/60hz) 6.Capable of maintain timing in power-off state 7.100 groups of programme/time periods Additional jump function, the number of cycle is settable
Features 1.Intelligent and digital led(light-emitting ) timer 2.1~8 channels, programmable and arbitrary combination and arbitrary output 3.Memory storage (10years) / mechanical life 4.Panel mounting 5.Delay time unit:0.1s/1s/1min(option) 6.Power supply (220v ac 50/60hz) 7.Input:transistor 8.100 groups of programme/time periods
1.New high-speed MCU chip with great speed 2.Big capacity of program and stable and reliable operation 3.Accomplishes the control of time-segment, sequential-segment and the program 4.Built-in 100 time relays 5.Be used in programmable fountain, programmable lights, sewerage, water supply, irrigation, bag pulse dust, electric boiler heating, street lights, neon light, water purifier,electric valve (solenoid valve)timing mud, grit removal control and so on. 6.The 220V/1A DC or AC load. 7.16/8-channel output
ENVIRONMENTAL CONDETIONS: Temperature Range: -55~+85 C Relative Humidity: Up to 98% at +40 C Atmospheric pressure: 86kPa~106kPa, Low pressure 4 kPa Vibration: 10~2000Hz, 196 m/s2 Shock: 735m/s2 Acceleration: 490 m/s2. TECHNICAL REQUIREMENTS: Rated Voltage: 12VDC, 18VDC, 24VDC, 27VDC Insulation Resistance: 1000Mohm Dieletric Withstanding Voltage: (RMS/50Hz) 500V Contact Resistance: 0.1ohm Rated Load: 2A28VDC, 4A28VDC Life: 1x105: 1x105 / 2x104 Contact Form: 2C(DPDT); Time Delay: 0.05~500s(Nonadjustable) Outline Dimensions: 20.5 x 10.5 x 15mm Weight: 13g .
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
ALSTOM GBCDG11AF9007ACH INVERSE TIME E/F RELAY MULTI-AUX-VOLTAGE Technical specification Relay model no CDG11AF9007ACH Relay type CDG 11 Case size 1D S/E Application E/F Current setting 1 to 4 amps C.T.Secondary 5 amps Taps Std Burden 3 VA Operating time 3 secs Frequency 50 Hz Aux.voltage vdc 30-50 / 100-125 V 220-250 V dc Contacts shunt 2 N/O S/R Flag Yes Mounting Type Flush Name plate RFG9126 796 Outline drawing MFJ 012 Wiring diagram MADZ 802.26-1
GBCDG31EG8101KCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE Model No : CDG31EG8101K(M) CDG31S/T APPLICATION - 3 O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C OR O/V SETTING - 2.5 -10 Amps. Name Plate RFG9126 774 Outline Diagram MFJ014 Wiring Diagram MADZ821-17
GBCDG31EG8101LCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE Model No - CDG31EG8101L(M) RELAY TYPE - CDG31S/T APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate - RFG9126 904 Outline Diagram MFJ014 Wiring Diagram MADZ821-17
ALSTOM GBCDG31EG8102LCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE Model No : - CDG31EG8102L(M) RELAY TYPE - CDG31S/T APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.5 - 2 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate - RFG9126 903 Outline Diagram MFJ014 Wiring Diagram MADZ821-17
ALSTOM GBCDG31EG8106LCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE Relay model no CDG31EG8106LCH Relay type CDG31 Case Size 3D Hor Application 2 O/C & 1 E/F C.T.Secondary 5 Amps Current Setting - O/C 2.5 TO 10 Amps Current Setting - E/F 1 TO 4 Amps Contacts 2 N/O 2 N/C H/R Output Contacts 2 N/O 2 N/C H/R Taps STD Burden / Operating Time 3 Va / 3 Secs. Frequency 50 Hz Name Plate RFG9126 904 Outline Drawing MFJ 014 Wiring Diagram MADZ821.42