1. General HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 v Control voltage: 36V, 110V, 220V, 380V Rated current: 250A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 4500,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
1. General HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36 V, 110 V, 220 V, 380 V Rated current: 1000A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 10000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 1.5*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
1. General HVJ5 1.14kv 125A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 125A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36V, 110V, 220V, 380V Rated current: 125A Opening distance: 1.8±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 2000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10 S Remark: “Ie” is Rated current of main circuit.
1. General HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 v Control voltage: 36V, 110V, 220V, 380V Rated current: 250A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 4500,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: Ie is Rated current of main circuit.
Canola Oil INGREDIENT SPECIFICATION: Canola Oil, NOP â?? Refined, Bleached and Deodorized CERTIFICATE OF ANALYSIS: Each shipment to include certificate. DESCRIPTION: Organic Canola seeds are pressed using cold-pressing technology, degummed, bleached (if necessary), and deodorized under vacuum and controlled temperature. APPEARANCE, FLAVOR & COLOR Light green in color with light taste AVERAGE ANALYSIS: IODINE VALUE: 100 â?? 130 PEROXIDE VALUE: 1.00 Max. FATTY ACID COMPOSITION: FREE FATTY ACID Max. 0.10% of Oleic Acid MYRISTIC ACID C 14:0 0.20 % Max. PALMITIC ADIC C 16:0 3.0 â?? 6.0 % PALMITOLEIC ACID C 16:1 0.60 % Max. STEARIC ACID C 18:0 1.0 â?? 3.0 OLEIC ACID C 18:1 51 â?? 70 % LINOLEIC ACID C 18:2 15 â?? 30 % LINOLENIC ACID C 18:3 5 â?? 15 % ARACHIDIC ACID C 20:0 0.2 â?? 1.2 % EICOSENOIC ACID C 20:2 0.1 â?? 3.0 % BEHENIC ACID C 22:0 0.5 % Max. ERUCIC ACID C 22:1 2.0 % Max. STORAGE: Store in a cool dry place away from direct sources of sunlight, heat, and oxidizers. Properly stored unopened containers have an expected shelf life of 24 months. MARKINGS: As per the buyer specification suggested: COUNTRY OF ORIGIN MANUFACTURER IMPORTER BATCH NUMBER PURCHASE ORDER NUMBER JULIAN DATE PACKAGING: Drums (55 gallon) DOCUMENTS: Lot or batch numbers Date of Manufacture Certificate of Analysis Kosher Certificate, if required Organic Certificate
We at GREENLAND FRESCO procure Peanuts in the most professional way and always ensure that fresh and healthy products are delivered to our clients. We keep pace with the latest technology and market requirements to ensure stability & sustainability towards fulfilling the clients demand. We have built a cost-effective and reliable supply chain to deliver Java & Bold varieties of Peanuts in one click. We maintain aflatoxin level & moisture content at minimal level. Peanuts are processed at processing plants to obtain the required specifications specified by our clients. Specifications of Bold / Java / Blanched Bold / Blanched Java Peanut kernels : - Type - Peanut kernels Peanuts counts per Ounce - 38/42, 40/50, 50/60, 60/70, 70/80 Origin - India Admixture - 1% max Oil content - 42% - 48% max Foreign Material - 0.50% max OR 1% max Moisture - 7% max OR 8% max Aflatoxin - Aflatoxin negative 5/10 PPB Gross Wt. per Bag - 10/15/25/50 Kgs Packaging Material - New Jute Bags Load Ability : One 20" FCL can load 19 MTS or 380 Bags of 50 Kgs New Jute Bags One 20" FCL can load 19 MTS or 760 Bags of 25 Kgs Vacuum Bags New vacuum pack inside and outer layer with PP woven bags 25 Kgs Gross Specifications of Peanuts in Shell Bold / Java : - Type - Peanuts in shell Bold : HPS- Ground nuts Peanuts bold shell - 18/22, 20/24, 22/26 Counts/Ounce Origin - India Moisture - 6-8% Max Admixture - 1% Max Imperfect - 5% Max Aflatoxin(B1+B2+G1+G2) - 5-10 ppb (as per clients specifications) Packing - In Strong Jute Bags of 30 Kgs Net/Gross Each One 20" FCL can load 12-14 MTS One 40" FCL can load 19-20 MTS Health Benefits 1. Peanuts have a strong nutritional Profile 2. Peanuts can reduce the risk of Heart disease 3. Peanuts are excellent source of plant based protein, fiber and many key vitamins and minerals. 4. Peanut consumption reduces the risk of weight loss and obesity 5. Peanut consumption reduces the risk of colorectal cancer
***SPECIFICATION*** 1/ Product name: FROZEN PEELED SUGARCANE Type: Completely Peeled Sugarcane Shape: 3-5 cm Packing: 1kg/ vacuum bag, carton 10kg or carton 20kg Freeze Temperature: -28 degree Loading: 12 MT/ Cont 20ft 2/ Product name: FROZEN SUGARCANE POLE Type: Pole Sugarcane Shape: 35 cm Packing: 1kg/ vacuum bag, carton 10kg or carton 20kg Freeze Temperature: +2 or +5 degree Loading: 14 MT/ Cont 20ft
1. General HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36 V, 110 V, 220 V, 380 V Rated current: 1000A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 10000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 1.5*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: Ie is Rated current of main circuit.
ESS 215KW Lithium Battery Energy Storage System 384VDC Rechargeable Lifepo4 Battery pack 280AH Energy Storage Battery 1. High energy density, small footprint, short construction period, strong environmental adaptability 2. Standardized components, modular architecture, easy for expansion 3. Battery module within the layered stack design, with more than 10 years of long design life 4. Efficient battery module and system cooling design 5. The use of international advanced IGBT and intelligent power module, with high power fast adjustment capability 6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management 7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system 8. Our BMS use NXP(USA) automotive-grade high performance chip, strong anti-interference, good reliability, wide temperature range. 9. We use brand new high quality A-grade battery power cell, longer service life. 10. Charging and discharging are controlled separately, more convenient and reliable to control charging and discharging. 11. Big color LCD touch screen display, easy setting and operation. 12. Can built in solar charge controller and AC-DC charger, our BMS can intelligently manage charger to charge battery well, BMS can communicate well with battery, solar controller, ac charger and inverter, one integrated intelligent monitoring system. 13. Approved by UL1741 certificate. 14. Accept customized product, our lithium battery system are widely used in many situations, such as: Different residential home, hotel, shop, factory, hospital, commercial buildings, electric car, RVs, Van, mobile dining car, heavy truck, different ship/boats, ice-cream car, outdoor camper,.etc. Applications: 1.Energy Storage --Solar-Wind Power System / City Grid (On/Off) / Community and Family 2.Back-up System and UPS --Telcom Base / CATV system / Computer Server Center / Medical Instrumnt / Military Equipment 3.Other Applications --Security and Electronics / Mobile POS, Mining Lihgt / Torch / LED Light / Emergency Light --RV Motorhome /Golf Carts Battery / Boat Marine Yachts / Electric Skateboard / Electric bike / Electric Scooter / Electric bicycle --LED Backup / Engine Starting Battery,etc.
ESS 215KW Lithium Battery Energy Storage System 384VDC Rechargeable Lifepo4 Battery pack 280AH Energy Storage Battery 1. High energy density, small footprint, short construction period, strong environmental adaptability 2. Standardized components, modular architecture, easy for expansion 3. Battery module within the layered stack design, with more than 10 years of long design life 4. Efficient battery module and system cooling design 5. The use of international advanced IGBT and intelligent power module, with high power fast adjustment capability 6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management 7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system 8. Our BMS use NXP(USA) automotive-grade high performance chip, strong anti-interference, good reliability, wide temperature range. 9. We use brand new high quality A-grade battery power cell, longer service life. 10. Charging and discharging are controlled separately, more convenient and reliable to control charging and discharging. 11. Big color LCD touch screen display, easy setting and operation. 12. Can built in solar charge controller and AC-DC charger, our BMS can intelligently manage charger to charge battery well, BMS can communicate well with battery, solar controller, ac charger and inverter, one integrated intelligent monitoring system. 13. Approved by UL1741 certificate. 14. Accept customized product, our lithium battery system are widely used in many situations, such as: Different residential home, hotel, shop, factory, hospital, commercial buildings, electric car, RVs, Van, mobile dining car, heavy truck, different ship/boats, ice-cream car, outdoor camper,.etc. Applications: 1.Energy Storage --Solar-Wind Power System / City Grid (On/Off) / Community and Family 2.Back-up System and UPS --Telcom Base / CATV system / Computer Server Center / Medical Instrumnt / Military Equipment 3.Other Applications --Security and Electronics / Mobile POS, Mining Lihgt / Torch / LED Light / Emergency Light --RV Motorhome /Golf Carts Battery / Boat Marine Yachts / Electric Skateboard / Electric bike / Electric Scooter / Electric bicycle --LED Backup / Engine Starting Battery,etc.
Technical Features: 1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance. 2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection. 3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance. 4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set. 5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. 6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy �±1%. 7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel. 8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load. 9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock. 10, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%. 11, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance. 12, The controller adopts three charging stages (buck charging, equalize charging and float charging) which can maximize the utilization of photovoltaic modules and batteries 13, Solar controller adopt IGBT Modular design ensure stable and efficiency performance of solar controller and solar power system 14, The controller has perfect battery protection function and with multi-stage charging technology to improve battery life 35% at least 15, Fully enclosed duct design and high-speed fan for cooling makes the controller working under harsh environments 16, The controller has power generation statistics and real-time power curve function, so we can know power generating information at any time 17, Colorful LCD display, touching key and multi-language option makes the HMC (Human Machine communication) easy and convenient. 18, The controller also has temperature compensation function and RTC real time clock function,
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc ( +10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80 C. When the DC panel has a temperature over 100 C, the module will stop working; when the DC panel has a temperature below 90 C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75200 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
We have good quality Used and New Laptops of all brands. Product Name Used laptops Processor CPU Series: Intel Core i7 4-generation family CPU Type: Intel Core i7 4702MQ CPU frequency: 2.2GHz Core frequency: 3200MHz Bus Specifications: DMI 5 GT / s Three cache: 6MB Core Architecture: Haswell Core / thread count: quad-core / eight thread Storage Device Memory Capacity: 4GB (4GB Ã?? 1) Memory Type: DDR3L (low voltage version) 1600MHz Hard disk capacity: 500GB Hard Description: Support the expansion turn mSATA SSD hard drive Drive Type: No built-in optical drive Display Touch screen: does not support touch Screen Size: 14 inches Aspect Ratio: 16:9 Screen Resolution: 1366x768 Screen technology: LED backlit, matte glare mask Graphics Graphics Type: Dual Graphics (fever-level graphics card + integrated graphics) Graphics chip: NVIDIA GeForce GTX 760M + Intel GMA HD 4400 Memory Capacity: 2GB Memory Type: GDDR5 Memory Interface: 128bit Number of stream processors: 768 Multimedia devices Camera: 720p HD webcam Audio System: Built-in audio chip Speaker: Built-in speaker Microphone: Built-in microphone Network Communications Wireless LAN: 802.11b/g/n wireless protocol Wired LAN: 100Mbps Ethernet card I / O interfaces Data interface: 1 Ã?? USB2.0 +2 Ã?? USB3.0 Video Interface: VGA, HDMI Audio interface: headphone / microphone combo interface Other interfaces: RJ45 (network interface), power connector Reader: Multi-in-1 card reader Input Devices Pointing device: Touchpad Keyboard Description: Full-size keyboard Power Description Battery: 6-cell lithium battery, 5900 mA Life time: 5 hours, the specific time depending on use environment Power adapter: 100V-240V 90W AC power adapter adaptive Exterior Laptop Weight: 2Kg Length: 339.2mm Width: 239.5mm Thickness: 26.4mm Shell material: composite material Case Description: Black Notebook accessories Packing list: Host x1 notebook Power adapter x1 Power cord x1 Manual x1 Warranty card x1 Shipping DOCS 1. Commercial Invoice 2. Packing list 3. Certificate of Origin 4. Bill of Loading 5. Form A/Form E 6. Other documents are according to customer's
V3 Borewell Submersible Pumpset Falcon standard 73mm (3") Borewell Submersible pump is firmly coupled to a submersible electric motor which Operates by being submerged beneath the surface of the water. The optimal design of impeller and diffuser enables the best Possible hydraulic efficiency. Built-in check valve prevents back flow and reduces the risk of water hammering. All Vital components of these pumps are made up of corrosion resistance thermoplastic and the shaft is of SS 410. Pump Liquids - Clean - Thin - Non-Aggressive - Non-Explosive - Clear - Cold - Fresh water - Without abrasives - Solid particles. Salient Features - Motor portion covered with corrosive resistance Stainless steel (SS 204cu) shell - More durability and hygiene - High operating efficiency - Specially designed thrust bearing to withstand high axial thrust load - Extremely hardwearing water lubricated bearing - Thread type motor construction ensures service feasibility - Specially designed Deep Drawn type pump ensures perfect alignment and Thereby increases the life of the pump set - Designed for wide voltage operation - Best alternative for JET & Compressor pump set - Additional intermediate bearing in higher stage pumps. Specification - Power Range : 0.37 kW to 1.1 kW (0.50 HP to 1.5HP) - Version : Single Phase 160V to 230V, 50Hz, AC Supply - Speed : 2880 RPM - Head Range : 14 Mtr. to 96 Mtr. - Discharge Range : 70 LPM to 15 LPM - Outlet Size in Inch : 1.25" - Degree of Protection : IP 58 - Direction of Rotation : Counter clockwise from driving end -1 pH Minimum cooling 1pH - Flow Along the Motor : 0.15 m/sec. - Type of Duty : S1 (Continuous) - Method of Starting : 1ph-Capacitor - Maximum Starts Per Hour : 20 Times Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 6 1.75 x 10 m�²/sec (max.) - Ph Value : 6.5 to 8.5
V3 Borewell Submersible Pumpset Falcon standard 73mm (3") Borewell Submersible pump is firmly coupled to a submersible electric motor which Operates by being submerged beneath the surface of the water. The optimal design of impeller and diffuser enables the best Possible hydraulic efficiency. Built-in check valve prevents back flow and reduces the risk of water hammering. All Vital components of these pumps are made up of corrosion resistance thermoplastic and the shaft is of SS 410. Pump Liquids - Clean - Thin - Non-Aggressive - Non-Explosive - Clear - Cold - Fresh water - Without abrasives - Solid particles. Salient Features - Motor portion covered with corrosive resistance Stainless steel (SS 204cu) shell - More durability and hygiene - High operating efficiency - Specially designed thrust bearing to withstand high axial thrust load - Extremely hardwearing water lubricated bearing - Thread type motor construction ensures service feasibility - Specially designed Deep Drawn type pump ensures perfect alignment and Thereby increases the life of the pump set - Designed for wide voltage operation - Best alternative for JET & Compressor pump set - Additional intermediate bearing in higher stage pumps. Specification - Power Range : 0.37 kW to 1.1 kW (0.50 HP to 1.5HP) - Version : Single Phase 160V to 230V, 50Hz, AC Supply - Speed : 2880 RPM - Head Range : 14 Mtr. to 96 Mtr. - Discharge Range : 70 LPM to 15 LPM - Outlet Size in Inch : 1.25" - Degree of Protection : IP 58 - Direction of Rotation : Counter clockwise from driving end -1 pH Minimum cooling 1pH - Flow Along the Motor : 0.15 m/sec. - Type of Duty : S1 (Continuous) - Method of Starting : 1ph-Capacitor - Maximum Starts Per Hour : 20 Times Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 6 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5
1. Introduction JCZ5 7.2 kv vacuum contactor HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment. 2. Service condition a) Ambient air temperature: -25?- +40?. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95?,monthly mean not higher than 90?; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5?. Main technical parameters Rated voltage: 7.2 kv Control voltage: 110V, 220V Rated current: 200A, 400A, 630A Contacts separation: 4.5+1-0.5mm Over travel: 1.5±0.5 mm Main circuit power frequency voltage withstand: 32000 V Auxiliary circuit power frequency withstand voltage: 2500 V Control circuit power frequency withstand voltage: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30×104 Weight: 28KG