Please click here to check who's online and chat with them.

Hvj6 Jcz5 7.2 Kv Vacuum Contactor 200A 400A 630A

Supplier From China
Aug-17-16

1. Introduction
JCZ5 7.2 kv vacuum contactor
HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment.
2. Service condition
a) Ambient air temperature: -25?- +40?.
b) Altitude not exceed 2000m
c)Humidity:
-Relative humidity: daily mean not higher than 95?,monthly mean not higher than 90?;
-Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP
Ambient air should not be obviously polluted by corrosive or flammable gas or vapor;
C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5?.

Main technical parameters
Rated voltage: 7.2 kv
Control voltage: 110V, 220V
Rated current: 200A, 400A, 630A
Contacts separation: 4.5+1-0.5mm
Over travel: 1.5±0.5 mm
Main circuit power frequency voltage withstand: 32000 V
Auxiliary circuit power frequency withstand voltage: 2500 V
Control circuit power frequency withstand voltage: 2000 V
Making capacity: 10le,100 times
Breaking capacity: 8le, 25 times
Limit breaking current(A): 10le
Mechanical life times: 30×104
Weight: 28KG

Price and Minimum Quantity

Price: $336
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Hvj6 Jcz5 7.2 Kv Vacuum Contactor 200A 400A 630A

VERIFIED
Sep-19-22
 
* 200 Amps Normally Open 24VDC with auxiliary switch
* Double coils
* Customized available
May-09-19
 
1. General
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

2. Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

Main models and technical parameters
Rated voltage: 7.2 kv
Control voltage: 380/220/110
Rated current: 630A
Clearance: 3.5±0.3 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 32000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 25.5 KG
Note: Ie represents the rated current of main circuit
May-09-19
 
1. General
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

2. Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

Main models and technical parameters
Rated voltage: 7.2 kv
Control voltage: 380/220/110
Rated current: 630A
Clearance: 3.5±0.3 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 32000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 25.5 KG
Note: Ie represents the rated current of main circuit
Aug-17-16
 
HVJ3 12KV VACUUM CONTACTOR
Detailed product description:
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

.Main models and technical parameters
Rated voltage: 12 KV
Control voltage: 220/110/380
Rated current: 160A, 250A, 400A, 630A
Clearance: 5±0.5 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 42000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 30KG
Note: “Ie” represents the rated current of main circuit
Aug-17-16
 
HVJ20 series vacuum contactor has higher rated current, smaller size and anti-dusty advantages. It can be used in AC50 ~ 60Hz, 2KV power system, rated current to 800A, for long distance making-breaking and frequent starting and controlling of AC motor.
Rated voltage: 2 kv / 2 kv
Rated current: 630A / 800A
Main circuit making ability (A/100 times): 6300 / 6300
Main circuit break-make ability (A/10 times): 5000 / 6000
Maximum breaking ability (A/3 times): 6300 / 6300
Electrical life AC3(times): 600,000 / 600,000
Electrical life AC4(times): 100,000 / 100,000
Mechanical life(times): 1,000,000 / 1,000,000
Rated operating frequency AC3(times /h): 300 / 300
Rated operating frequency AC4(times /h): 120 / 120
Short-time operating frequency times /h(20S): 1200 / 1200
Clearance between open contacts(mm): 3±0.3 / 3±0.3
Over travel(mm): =1 / =1
Aug-17-16
 
1. General
HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on.
2. Main technical parameter
Rated voltage: 1140 v
Control voltage: 36V, 110V, 220V, 380V
Rated current: 250A
Opening distance: 2±0.2 mm
Over travel: 1±0.2 mm
Final pressure: 30±3 N
Main circuit power frequency voltage withstand: 4200 V
Auxiliary circuit power frequency voltage withstand: 2500 V
Control circuit power frequency voltage withstand: 2000 V
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit breaking current(A): 4500,3 times
Electricity life times AC3: 60*104
Electricity life times AC4: 60*104
Mechanical life times: 300*104
Overload capacity: 8Ie 10S
Remark: “Ie” is Rated current of main circuit.
Aug-17-16
 
1. General
HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on.
2. Main technical parameter
Rated voltage: 1140 V
Control voltage: 36 V, 110 V, 220 V, 380 V
Rated current: 1000A
Opening distance: 2±0.2 mm
Over travel: 1±0.2 mm
Final pressure: 30±3 N
Main circuit power frequency voltage withstand: 4200 V
Auxiliary circuit power frequency voltage withstand: 2500 V
Control circuit power frequency voltage withstand: 2000 V
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit breaking current(A): 10000,3 times
Electricity life times AC3: 60*104
Electricity life times AC4: 1.5*104
Mechanical life times: 300*104
Overload capacity: 8Ie 10S
Remark: “Ie” is Rated current of main circuit.
VERIFIED
Jun-07-21
Supplier From Anand, Gujarat, India
 
Toshiba Cv-6ha , Contactor Magnetic, Ctry.mfg Toshiba Part Cv-6ha, 100-110 V Ac/dc, 50/60 Hz, 7.2 Kv, 6.6-3.3 Kv Operational Voltage, 400a, Draw-out Type, Vacuum Contactor With Clf Fuse.

The Toshiba HCV-6KAU and HCV-6KALU
vacuum contactors described in this manual are
suitable for use on systems of 7.2kV 720A
7.2kA.
Arc interruption is accomplished inside sealed vacuum interrupters mounted on track-resistant insulators. Vacuum interrupters use low-surge contact materials, which exhibit low current chopping levels reducing switching over-voltage.
VERIFIED
Jun-09-21

C&s Mccb

$41
MOQ: Not Specified
Supplier From Anand, Gujarat, India
 
C&S MCCB , Moulded Case Circuit Breakers - Winbreak2
RANGE : Rating: 16A~1600A , Poles: 3P & 4P.

Moulded Case Circuit Breakers - Winbreak
RANGE: Rating: 15A ~ 1200A , Poles: 2P, 3P & 4P

Moulded Case Circuit Breakers - WiNbreak1
RANGE : Rating: 16A ~ 400A in 3P & 4P
Rating: 16A ~ 200A in single pole

Verification Status