Gel and Clot Activator Tube aims to obtain high quality serum specimen for biochemistry , immunology and serology tests in clinical inspection. Inside the tube there is some gel present at the bottom, which is a pure substance and is very stable in physico-chemistry properties. Otherwise, the gel can avoid high- temperature decomposition and small molecules precipitation, hence it greatly reduces the risk of testing equipment clogging.
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mmï¼?13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
Also known as Serum separating tubes Gel separates the serum and the blood clot during centrifugation of the GEL-SST Advance tubes, preventing the serum from being affected by the separated cellular components. Material: PET & PP Type of Additive: Silicone Gel & clot activator Size: 13X75 mm, 13X100mm Capacity: 3.5mL, 4mL, 5mL, 6mL Available in: Vacuum and Non-Vacuum Colour Code: Yellow Available Packaging: Inner Packaging 100 pieces, Outer Carton Packaging 1200 pieces Used for: Endocrinology, Toxicology, Microbiology, Immunology & urea test C reactive protein test * Serum Separation Tubes should be gently inverted 180 and back 6-8 times
CE&ISO certified manufacturer of medical supplies medical lab consumables+8613930205358 Product name: blood collection tube Type:Vacuum or non vacuum,micro blood collection tube Spec: Gel+clot activator tube,plain tube/no additive tube, clot activator tube,sodium heparin/lithium heparin tube,PT tube/3.2% sodium citrate tube,edta k3k2 tube,ESR tube,glucose tube Cap Color:purple/Lavender/Red/Yellow/Blue/Green/Gray/Black Material:PET plastic or Glass Tube size :13*75mm,13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Brand:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
Led bulb, tube light, panel light, decoration light, wall light, steel wires, steel plate, stainless steel plate, twisted wire rods, galvanized wires, wire mesh, site fencing, mosquito mesh, thread rods, rebar, twisted rods, t bar, nuts and bolts, hardware, pvc pipes, upvc pipes, api pipes, melamine, mdf board, plywood, film faced, shuttering, packing, core veneer, face veneer, hdf molded door skin, door filler, tubular particle boards, pvc boards, wpc boards, doors, block board, hard board, gypsum board, canopy, carpet, flooring wooden, bamboo, laminated engineering, tiles, granite tiles, granite blocks, black galaxy, wash basin, water closets, washbasins, ss sinks, faucets, furniture, pvc edge bending, crew, locks, pvc seals, silicone cartridges, shower enclosures, shower door hinges, handles, knobs, brackets, slides, nails, solar panels, flexible solar panels, solar power station, battery, inverters, rechargeable fans, lights, spring, 3ply disposable face mask, oxygen concentrator ,.Buying office, oem, components sourcing, value added services
Serum Blood Collection Tube Golden Vac serum blood collection tube promises to provide non-polluting and non-different original blood specimen for medical test. After centrifugation, serum can be separated from blood cells and fibrin effectively. Serum tube includes 3 kinds of tubes: 1. Plain Tube with red cap, 2. Pro-coagulation Tube with red cap, 3. Gel&Clot Activator Tube with yellow cap Plain Tube aims to obtain serum specimen forbiochemistry, immunology and serology tests in clinical inspection. Its main merit is that serum separate out of blood cells and fibrin naturally, so its physico-chemical properties are keeping nonpolluted. The intact serum is suitable for a wide range of laboratory operation, routine clinical chemistry, immunology and serology. Item No . GD020A , Specification Red cap, Plain, 13*75mm, 2ml Item No . GD030A , Specification Red cap, Plain, 13*75mm, 3ml Item No . GD040A , Specification Red cap, Plain, 13*75mm, 4ml Item No . GD050A , Specification Red cap, Plain, 13*75mm, 5ml Item No . GD060A , Specification Red cap, Plain, 13*100mm, 6ml Item No . GD070A , Specification Red cap, Plain, 13*100mm, 7ml Item No . GD090A , Specification Red cap, Plain, 16*100mm, 9ml Item No . GD100A , Specification Red cap, Plain, 16*100mm, 10ml Item No . GD090AR , Specification Rubber stopper, Plain, 16*100mm, 9ml Item No . GD100AR , Specification Rubber stopper, Plain, 16*100mm, 10ml
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mm 13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
Hand Sanitizer Clean Gel and Spray 1. Excellent removal of varlous harmful bacteria - Removal of various harmful bacteria that cause cold, food poisoning, and eye disease 2. Powerful cleaning - Optimal bactericidal effect containing a high concentration of 70% ethanol 3. Easily without water and soap - Easy to use without water and soap and towels * Price specially negotiable for larger quantities over 10,000pcs and 100,000 pcs respecitvely
- Material : Solid SS304, SS316, SS316L ( also available in some models with hollow tube) - Shape at top of the spigot: Round/dome top or slopped as shown in the picture) - Also available in Square shape - Spigot no hole in the glass panel. - Spigot with base plate and cover ring - Dimensions: 48 x 155mm, 48*220mm, 48*300mm with base plate. - include the black gasket and stainless steel insert - Mirror polished or satin stainless steel.
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
3ply face mask comfortable for user. The face mask is latex free and use brand new hypoallergenic material, odourless and lint free. Product Disposable 3-Ply Non-Woven Face Mask with Ear Loop Size 18cm x 9.5cm (18cm after expended) Color Blue/Green/White/Yellow/Pink or can be customized Outer Layer Spund-bound PP Nonwoven: 20 - 25 gsm Filter Medium Meltblown PP Nonwoven: 18 - 20gsm Inner Layer Lint free ES Nonwoven: 25 gsm Nose Piece Aluminum Packaging 50 pieces per box or 50pcs per bag; 10 boxes/bags per carton. 1600 cartons/20 ft container , 3200 carton/40 HQ container. MOQ 50,000 pieces min order Quantity: 10,000PCS/Day MOQ : 10,000 pieces Packaging: 50 pieces per box/bag; 40 boxes per carton. Payment condition: TT Shipping Duration: 7 Days ( ONE WEEK) Origin: Thailand/China Condition: Subject to availability