Eltek Valere FLATPACK2 Rectifier Module 48/2000 Norway Eltek Rectifier FLATPACK 48/2000 A&S provides all models of Eltek Rectifiers. Models we offer: Eltek Valere FLATPACK2 Rectifier Module 48/2000, Eltek Valere FLATPACK2 Rectifier Module 48/650 HE, Eltekvalere Rectifier Module X5000A3, Eltekvalere Rectifier Module J0500A1, Eltekvalere Rectifier Module V2000D.etc. If failed to find your ideal models, pls send details to our email box. You'll be responded within one working day. We still distribute original thyristors/rectifiers of world's leading brands. ABB Thyristor, ABB Rectifier GE Thyristor, GE Rectifier AEG Thyristor, Infineon Thyriostor IR Thyristor, IR Rectifier IXYS Thyristor, NXP Thyristor Mitsubishi Thyristor, Mitsubishi Rectifier ON Semiconductor Thyristor PRX Thyritor, Renesas Thyristor Westcode Thyristor, ST Thyristor SEMIKRON Thyristor, SEMIKRON Rectifier SanRex Thyrisotr, SanRex Rectifier Toshiba Thyristor, Tyco Rectifier Vishay Thyristor, Vishay Rectifier Emerson Rectifier, Valere Rectifer Nell Thyristor, Techele Thyristor, Eaton Rectifer, Benning Rectifier Eltek Rectifier, BOSCH Rectifier Littelfuse Thyristor,Alpha Rectifier JieJie Microelectronics,EUPEC Thtristor Westinghouse Thyristor, Westinghouse Rectifier NELL Thyristor, GOLD Thyristor, POSEICO Thyristor, CLION Thyristor.etc.
V2500A Eltek V-Series rectifier modules provide unprecedented power density and in a truly compact, plug-and-play format. With a wide range of available voltages, power ratings, and system form factors, Elteks power modules allow optimally system design and cost-effective deployment from initial install to future upgrades.
Eltek Rectifier Module Flatpack MCU
Original Eltek Rectifier Module Flatpack 2500
Flatpack2 48V 2000W Super HE Eltek Rectifier Module 241119.106 APPLICATIONS TELECOM - WIRELESS Radio base station / Cell sites LTE / 4G / WiMAX Mobile switching center (MCS) Microwave Broadband TELECOM - FIXED Central office Telephony servers / switches Fiber optics Microwave Broadband Broadcast Data center Key Features SUPER HIGH EFFICIENCY â?? 97.8% HIGH POWER DENSITY â?? 33 W/IN3 COMPATIBLE WITH EXISTING SYSTEMS GLOBAL COMPLIANCE PATENTED TECHNOLOGY HOT PLUGGABLE Super High Efficiency (SHE) rectifiers for Telecom applications The Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market. With an efficiency of 97.8% the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid connected applications the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster. The Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module. Specifications Model 48/3000 SHE Part number 241119.106 INPUT DATA Voltage (nominal range) 206 - 264 VAC Voltage (operating range) 85 - 264 VAC Frequency 45 - 66 Hz Maximum current 16 ARMS Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range
High efficiency and reliable rectifiers The most efficient power conversion module in the industry! Since the launch the Flatpack2 family has expanded into a wide selection of power ratings and voltages. Power systems up to the MW-range can be realized using the 10A model addressing small and larger modular data centersâ?? power needs. 220VDC power systems provide an excellent alternative to traditional AC UPS providing significant efficiency and reliability improvements. With 220V DC, standard components, cables and distribution can be used and most IT equipment designed for 208/ 230V AC can be connected directly to the 220V DC bus. Applications Power Utilities Switch Tripping Control & Protection Systems Emergency Lighting Railway Infrastructure Converter Stations Power Stations Marine And Off-Shore Central Power System Data Center Central Power System Dc/ Dc - Isolate Branches Specifications Part number 241115.815 Model 220 / 2000 HE WOR INPUT DATA Voltage range 85 - 300 V AC/ DC Voltage range (nominal) 185 - 275 V AC/ DC Frequency 0 - 66 Hz Maximum current 11.9 A RMS Power Factor 0.99 (@ 50-100% load) THD (@ 230 VAC) < 5 % (@ full load) Protection Varistor for transient protection, fuse in both lines, shutdown above 300/ 305 V OUTPUT DATA Default voltage 245.3 V DC Voltage range 178.5 1) - 297 VDC
Model 48/2000 SHE Part number 241115.106 INPUT DATA Voltage (nominal range) 185 - 264 VAC Voltage (operating range) 85 - 264 VAC Frequency 45 - 66 Hz Maximum current 11.6 ARMS Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.21) - 57.6 VDC Max power, nominal input 2000 W Max power, de-rated @VIN = 85 VAC 850 W Max current, @VOUT = 48 VDC 41.7 A Current sharing �±5.0% of max current Static voltage regulation (10-100% load) �±0.5% Dynamic voltage regulation 5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time (3000W load) >10ms; output voltage > 42 VDC Ripple
Model 48V / 2000W HE Part number 241115.105 INPUT DATA Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC Voltage (range) 85 - 300 VAC / 85 - 275 VDC Frequency 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz Current (maximum) @ nominal input, full load 11.6 ARMS Protection Fuse in both lines Varistor for transient protection Disconnect above 300 VAC/DC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.5 - 57.6 VDC Power (maximum) 2000 W Power @ 85 VAC 850 W Current (maximum) @ nominal input, full load 41.7 A Ripple, 30MHz bandwidth < 100 mVpp Psophometric noise < 2 mVRMS Static Voltage regulation �±0.5% for 10 - 100% load Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Protection Fuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limiting OTHER SPECIFICATIONS Efficiency @ nominal input 96 % Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth Alarms: Red LED 'on' Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings: Yellow LED 'on' Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (module running): Green LED 'on' Acoustic noise, full load @ Tambient = 25�°C full load @ Tambient = 40�°C < 20 dBA < 56 dBA MTBF (Telcordia SR-332 Issue I method III (a)) >350 000 (@ Tambient : 25 �°C) Operating temperature -40 to +75�°C (-40 to +167�°F)4), humidity 5 - 95% RH non-condensing Temperature de-rating >55�°C (131�°F), 1200W @ 75�°C (167�°F) Storage temperature -40 to +85�°C (-40 to +185�°F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13â??) / 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, UL 60950-1:2014, CSA C22.2 No.60950-1-07:2014, IEC 60950-1:2013 EMC EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, EN 61000-3-2:2019 ETSI EN 300 386 V.2.1.1, Telcordia NEBS GR1089 CORE Marine DNVGL-CG-03392) Environment ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised
Original Rectifier Module Eltek Flatpack2 48/2000 BF
Original Eltek Rectifier Module Flatpack2 48/1500 HE SOLAR
Eltek Micropack Rectifiers 12V/120W 241120.300 INPUT DATA Voltage range 85 - 300 VAC/DC 1) Voltage range (nominal) 130 - 275 VAC/DC 185 - 275 VAC/DC 1) Frequency 0 - 66 Hz 1) Maximum current, 230V input / overall (boost) 0.6 A / 2.0 A 1.2 A / 2.0 A 1.2 A / 1.9 A Maximum earth leakage current 2.0 mA (@ 250VAC/50Hz) Power Factor 0.97 (@ 70 - 100 % load) 0.98 (@ 55 - 100 % load) 0.98 (@ 50 - 100 % load) THD (@ 230 VAC) < 5 % (@ 80 - 100 % load) < 5 % (@ 50 - 100 % load) < 5 % (@ 50 - 100 % load) Protection Varistor for transient protection, fuse in both lines (2x 2.0 A), shutdown above 300 VAC/DC OUTPUT DATA Default voltage 13.6 VDC 27.2 VDC 53.5 VDC Voltage range 10.7 - 18.0 VDC 21.5 - 36 VDC 43.5 - 57.6 VDC Voltage range without controller 10.7 - 15.0 VDC 21.5 - 30 VDC 43.5 - 57.6 VDC # Pb cell supported (1.8 - 2.4 VDC/cell) 6 - 7 12 - 15 24 # NiCad cell supported (1.05 - 1.65 VDC/cell) 10 - 112) 20 - 222) - Max power, nominal / 60s boost 120 W / 160 W 240 W / 315 W 250 W / - Max current, @12/24/48VDC / boost / QT3) 10 A / 15 A / 55 A 10 A / 15 A / 55 A 5 A / - / - Current sharing �±5% of maximum current from 10 to 100% load Static voltage regulation �±0.5% from 10% to 100% load and nominal input Dynamic voltage regulation �± 5 % < 10ms, load step 10% to 90% or opposite at nominal output voltage Hold-up time, default voltage and full power 20 ms, VOUT > 10.7 VDC 20 ms, VOUT > 21.5 VDC 20 ms, VOUT > 43 VDC Rippel and noise, 30 MHz b.w. / psophometric < 200 mVPP / 5 mVRMS < 200 mVPP / 5 mVRMS < 150 mVPP / 2 mVRMS Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting, fuse
Eltek Flatpack2 Rectifier Module 110V 2000W HE WOR 241119.805 Overview High efficiency and reliable rectifiers The most efficient power conversion module in the industry! Since the launch the Flatpack 2 family has expanded into a wide selection of power ratings and voltages Key Feature Proven Reliability High Power Density Application Flexibility, 2kw - 2m Accepts Dc Input (Dc/ Dc Converter) Global Compliance (Ce, Ul, Nebs) Marine & Offshore Certification Patented Technology Digital Controllers Applications Power Utilities Switch Tripping Control & Protection Systems Emergency Lighting Railway Infrastructure Converter Stations Power Stations Various other applications in demanding industries like marine, oil & gas, process etc. Specifications Part number 241119.805 Model 110-120 / 20A HE INPUT DATA Voltage range (nominal) 176 - 277 V AC 1) Voltage range 85 - 305 V A 1) C Frequency 45 - 66 Hz Maximum current 18.64 ARMS Power Factor 0.99 (@ 50-100 % load) THD (@ 230 VAC) < 4 % (@ full load) Protection Varistor for transient protection, fuse in both lines, shutdown above 300/ 305 V OUTPUT DATA Default voltage 122.5 V DC Voltage range 90.02) - 151.25 V D 1) C # Pb cell supported (1.8 - 2.4 V DC/ cell) 54 -60 # NiCad cell supported (1.05 - 1.65 V DC/ cell) 86 - 91 Max power, nominal input 3025 W1) Max power, 85V input 1280 W Max current 20 A Hold-up time, default voltage and 1500 W load 10 ms, VOUT > 99.7 VDC Current sharing �±5% of maximum current from 10 to 100% load Static voltage regulation �±0.5% from 10% to 100% load and nominal input Dynamic voltage regulation �±5.0% for 10-80% or 80-10% load variation, regulation time < 50ms Rippel and noise, 30 MHz bandwidth < 500 mV PP Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug -in inrush current limiting, ORing diode
Eltek Micropack Rectifiers 24V/240W 241120.200 The Micropack System is convection cooled, designed for less power-hungry applications, but still with system functionality options to match any requirements. Use as stand-alone or in a flexible off-the-shelf configurable system. The Micropack Power System extends your network one step further. With load ranges typically between 120W and 1000W, and in 12, 24, and 48V options, the system is perfect for a great variety of applications.
Flatpack2 380V Rectifier Doc 241119.825.DS3 v4 Model Flatpack2 380/3000 HE (UI) Part number 241119.825 INPUT DATA Voltage (nominal) 176 - 277 VAC / 260 - 400 VDC1) Voltage (range) 85 - 305 VAC / 260 - 410 VDC1) Frequency 45 - 66 Hz / 15 - 18.5 Hz2) / DC1) Current (maximum) @ nominal input, full load 18.2 ARMS Power Factor > 0.99 at 50% load or more Protection Fuse in L & N Varistor Disconnect when VIN is out of range OUTPUT DATA Voltage (default) 381 VDC Voltage (adjustable range) 300 - 400 VDC # Pb cell supported 156 - 168 3) Power continuous (maximum) 3000 W Power @ 85 VAC / 85 VDC 1200 W Current continuous (maximum) 9 A (@VOUT < 336 VDC) / 7.9 A (@ VOUT = 381 VDC) Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) ±0.5% Dynamic Voltage regulation ±2.0% for 10-90% or 90-10% load variation, regulation time < 10 ms 5) Hold up time > 20 ms; output voltage > 300 VDC at 1500 W load Ripple < 1000 mVP-P , 30 MHz bandwidth Protection Overvoltage shutdown, Hot plug-in - Inrush current limiting, ORing diode, Fuse5), Short circuit proof, High temperature protection, Overload shutdown4) OTHER SPECIFICATIONS Efficiency @ 230 VAC / 380VDC input 96.2% / 96.6% Isolation 3.0 kVAC input to output, 1.5 kVAC input to earth, 1.5 kVDC output to earth, 3.0 kVAC CAN to primary, 3.0 kVAC CAN to secondary Alarms (Red LED) Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings (Yellow LED) Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (Green LED) Input and output ok Acoustic noise, at nominal input and full load < 40dBA @Tambient< 25C / 40C MTBF (Telcordia SR-232 Iss.3 Meth. II Case L1) 2 291 210h (@ Tambient = 25 C) Operating temperature -40 to +75C (-40 to +167F), humidity 5 - 95% RH non-condensing Output power de-rates linear from 3000W @ 50C (122F) to 980W @ 7C(167F) Storage temperature -40 to +85C (-40 to +185F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327 mm (4.25 x 1.69 x 13) / < 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013, UL 60950-1:2014, CSA C22.2 No. 60950-1-07 EMC EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010, IEC61000-6-5: 2015, EN 300 386:v1.6.1, FCC CFR 47 Part 15:2013 Environment Tested according to: ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE)
Eltek Micropack 48V/250W Rectifier 241120.100 Eltek Micropack System is convection cooled, designed for less power-hungry applications, but still with system functionality options to match any requirements. Use as stand-alone or in a flexible off-the-shelf configurable system. Eltek Micropack Power System extends your network one step further. With load ranges typically between 120W and 1000W, and in 12V, 24V, and 48V options, the system is perfect for a great variety of applications.
24V 1000W Rectifier Module Eltek Flatpack S 24/1000 HE 241122.205 Eltek 241122.205 Profile � The combination of innovative design, efficiency and reliability makes the Flatpack S a perfect choice for telecom and industrial applications. With a system depth of only 250mm the Flatpack S systems will fit in most cabinets. This Flatpack S reduces losses by 30% compared to the current industry standard. The result is reduced total cost of ownership for the customers as well as contribution to reducing the global carbon emissions. Key Features Small Short Power dense, 26 W/inch3 High efficiency OR-ing protection on output Hot pluggable Voltage keying Description Compact and reliable rectifier for rail and power utilities applications Used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation. Applications in these markets demand state of the art, reliable and safe DC power systems. Flatpack S delivers an industry leading power density in its segment, many safety functions, wide operating temperature range and superb reliability in its small 217mm deep housing. Specifications Input Voltage AC (operating range) 85 - 305 VAC Voltage DC (operating range) 85 - 300 VDC DC Output Max Power 1000 W Voltage (adjustable range) 41,7 - 21,5 VDC Current (maximum) 28 ADC Max voltage 21,5 VDC Other Cooling Single fan Efficiency 92,5 % Operating temperature -40 - 85 �°C Dimensions Dimensions WxHxD (mm) 72 x 41,5 x 217 mm Dimensions WxHxD (inch) 2,83 x 1,63 x 8,54 " Weight 0,85 lbs Design Standards Ingress Protection (IP) 20 Certifications Marine DNV 2.4 Valid for part no. 241122.205M
ELTEK FLATPACK2 48V/3000W HE Rectifier Module 241119.903 INPUT DATA Voltage (nominal) 176 - 275 VAC Voltage (operating range) 85 - 300 VAC Frequency 45 - 66 Hz Current (maximum) 19 ARMS Power Factor > 0.99 at 50-100% load Protection Fuse in L & N, Varistor, Shutdown above 300 VAC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.2 - 57.6 VDC Power @ 230 VAC 3000 W Power @ 85 VAC 1380 W Current 62.5 A (@ 48 VDC) Current sharing (10 - 100% load) �±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) �±0.5% Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time, 1500 W / 3000 W output power >20ms / >10ms ; output voltage > 43 VDC Ripple < 150 mV peak to peak, 30 MHz bandwidth Protection Fuse, Short circuit proof, High temperature protection, Overvoltage shutdown, Hot plug-in inrush current limiting
Flatpack2 48V SHE Rectifiers Flatpack2 48V Super HE 48/2000 SHE Eltek Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market. With an efficiency of 97.8%, the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid-connected applications, the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster. Eltek Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module.
241122.125 48/1800 HE Eltek Flatpack S 48V 1800W Rectifiers Description Compact HE rectifiers for small to medium telecom applications The Flatpack S rectifiers incorporate Telecom specifications, high efficiency, ORing protection on output and high power in a small, 217 mm deep box. Used in the 1U high, 2 or 3 rectifier positions power rack with Smartpack S controller and battery and load distributions, the Flatpack S rectifiers cover 2 to 5.4kW applications using a minimum of space, less than 6 liters, and low heat dissipation. Applications TELECOM â?? MOBILE / WIRELESS Radio base stations/ cell sites Lte / 4g / wimax Distributed antenna systems Microwave Broadband TELECOM - FIXED Telephony servers / switches Fiber optics / FTTx Microwave Cable BROADBAND Features Small Short Power Density - 47 w/Inch 3 High Efficiency Oring Protection On Output Hot Pluggable Voltage And Power Keying Specifications Model 48/1800 HE Part number 241122.125 INPUT DATA Voltage (nominal) 195 - 277 VAC / 195 - 250 VDC 1) Voltage (operating range) 85 - 305 VAC / 85 - 250 VDC 1) Current (maximum) @ nominal input, full load 9.9 ARMS Frequency 45 - 66 Hz / 0 Hz1) Power Factor > 0.99 at 50% load or more Protection Fuse in L & N, Varistor, Shutdown when input voltage is out of operating range
36/1000 HE UI ELTEK Flatpack S rectifier 36/1000 HE UI 241122.235 INPUT DATA Voltage (nominal) 185 - 400 VDC / 185 - 275 VAC Voltage (operating range) 85 - 400 VDC / 85 - 305 VAC Frequency DC, 16 2/3 Hz, 45 - 66 Hz Current (maximum) 5.9 ADC / 5.9 ARMS Protection Fuse in Positive & Negative, Reversed polarity insensitive, Shutdown above 420 VDC / 305 VAC OUTPUT DATA Voltage 40 VDC Voltage (adjustable range) 331) - 45 VDC Power (maximum) @ nominal input 1000 W / 450 W @16 2/3 Hz input Power (maximum) @ 85 VDC / 85 VAC input 440 W / 440 W Current (max cont.) @ nominal input 27.8 A (@VOUT < 36 VDC) Hold up time, maximum output power >10ms; output voltage > 33 VDC Current sharing (10 - 100% load) �±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) �±0.5% Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Ripple < 150 mVPP , 30 MHz bandwidth Protection ORing FET Short circuit proof High-temperature protection Overvoltage Shutdown