Flatpack2 48V 2000W Super HE Eltek Rectifier Module 241119.106
APPLICATIONS
TELECOM - WIRELESS
Radio base station / Cell sites
LTE / 4G / WiMAX
Mobile switching center (MCS)
Microwave
Broadband
TELECOM - FIXED
Central office
Telephony servers / switches
Fiber optics
Microwave
Broadband
Broadcast
Data center
Key Features
SUPER HIGH EFFICIENCY â?? 97.8%
HIGH POWER DENSITY â?? 33 W/IN3
COMPATIBLE WITH EXISTING SYSTEMS
GLOBAL COMPLIANCE
PATENTED TECHNOLOGY
HOT PLUGGABLE
Super High Efficiency (SHE) rectifiers for Telecom applications
The Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market.
With an efficiency of 97.8% the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid connected applications the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster.
The Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module.
Specifications
Model 48/3000 SHE
Part number 241119.106
INPUT DATA
Voltage (nominal range) 206 - 264 VAC
Voltage (operating range) 85 - 264 VAC
Frequency 45 - 66 Hz
Maximum current 16 ARMS
Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range
High efficiency and reliable rectifiers The most efficient power conversion module in the industry! Since the launch the Flatpack2 family has expanded into a wide selection of power ratings and voltages. Power systems up to the MW-range can be realized using the 10A model addressing small and larger modular data centersâ?? power needs. 220VDC power systems provide an excellent alternative to traditional AC UPS providing significant efficiency and reliability improvements. With 220V DC, standard components, cables and distribution can be used and most IT equipment designed for 208/ 230V AC can be connected directly to the 220V DC bus. Applications Power Utilities Switch Tripping Control & Protection Systems Emergency Lighting Railway Infrastructure Converter Stations Power Stations Marine And Off-Shore Central Power System Data Center Central Power System Dc/ Dc - Isolate Branches Specifications Part number 241115.815 Model 220 / 2000 HE WOR INPUT DATA Voltage range 85 - 300 V AC/ DC Voltage range (nominal) 185 - 275 V AC/ DC Frequency 0 - 66 Hz Maximum current 11.9 A RMS Power Factor 0.99 (@ 50-100% load) THD (@ 230 VAC) < 5 % (@ full load) Protection Varistor for transient protection, fuse in both lines, shutdown above 300/ 305 V OUTPUT DATA Default voltage 245.3 V DC Voltage range 178.5 1) - 297 VDC
Model 48/2000 SHE Part number 241115.106 INPUT DATA Voltage (nominal range) 185 - 264 VAC Voltage (operating range) 85 - 264 VAC Frequency 45 - 66 Hz Maximum current 11.6 ARMS Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.21) - 57.6 VDC Max power, nominal input 2000 W Max power, de-rated @VIN = 85 VAC 850 W Max current, @VOUT = 48 VDC 41.7 A Current sharing �±5.0% of max current Static voltage regulation (10-100% load) �±0.5% Dynamic voltage regulation 5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time (3000W load) >10ms; output voltage > 42 VDC Ripple
Model 48V / 2000W HE Part number 241115.105 INPUT DATA Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC Voltage (range) 85 - 300 VAC / 85 - 275 VDC Frequency 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz Current (maximum) @ nominal input, full load 11.6 ARMS Protection Fuse in both lines Varistor for transient protection Disconnect above 300 VAC/DC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.5 - 57.6 VDC Power (maximum) 2000 W Power @ 85 VAC 850 W Current (maximum) @ nominal input, full load 41.7 A Ripple, 30MHz bandwidth < 100 mVpp Psophometric noise < 2 mVRMS Static Voltage regulation �±0.5% for 10 - 100% load Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Protection Fuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limiting OTHER SPECIFICATIONS Efficiency @ nominal input 96 % Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth Alarms: Red LED 'on' Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings: Yellow LED 'on' Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (module running): Green LED 'on' Acoustic noise, full load @ Tambient = 25�°C full load @ Tambient = 40�°C < 20 dBA < 56 dBA MTBF (Telcordia SR-332 Issue I method III (a)) >350 000 (@ Tambient : 25 �°C) Operating temperature -40 to +75�°C (-40 to +167�°F)4), humidity 5 - 95% RH non-condensing Temperature de-rating >55�°C (131�°F), 1200W @ 75�°C (167�°F) Storage temperature -40 to +85�°C (-40 to +185�°F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13â??) / 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, UL 60950-1:2014, CSA C22.2 No.60950-1-07:2014, IEC 60950-1:2013 EMC EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, EN 61000-3-2:2019 ETSI EN 300 386 V.2.1.1, Telcordia NEBS GR1089 CORE Marine DNVGL-CG-03392) Environment ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised
Eltek Flatpack2 Rectifier Module 110V 2000W HE WOR 241119.805 Overview High efficiency and reliable rectifiers The most efficient power conversion module in the industry! Since the launch the Flatpack 2 family has expanded into a wide selection of power ratings and voltages Key Feature Proven Reliability High Power Density Application Flexibility, 2kw - 2m Accepts Dc Input (Dc/ Dc Converter) Global Compliance (Ce, Ul, Nebs) Marine & Offshore Certification Patented Technology Digital Controllers Applications Power Utilities Switch Tripping Control & Protection Systems Emergency Lighting Railway Infrastructure Converter Stations Power Stations Various other applications in demanding industries like marine, oil & gas, process etc. Specifications Part number 241119.805 Model 110-120 / 20A HE INPUT DATA Voltage range (nominal) 176 - 277 V AC 1) Voltage range 85 - 305 V A 1) C Frequency 45 - 66 Hz Maximum current 18.64 ARMS Power Factor 0.99 (@ 50-100 % load) THD (@ 230 VAC) < 4 % (@ full load) Protection Varistor for transient protection, fuse in both lines, shutdown above 300/ 305 V OUTPUT DATA Default voltage 122.5 V DC Voltage range 90.02) - 151.25 V D 1) C # Pb cell supported (1.8 - 2.4 V DC/ cell) 54 -60 # NiCad cell supported (1.05 - 1.65 V DC/ cell) 86 - 91 Max power, nominal input 3025 W1) Max power, 85V input 1280 W Max current 20 A Hold-up time, default voltage and 1500 W load 10 ms, VOUT > 99.7 VDC Current sharing �±5% of maximum current from 10 to 100% load Static voltage regulation �±0.5% from 10% to 100% load and nominal input Dynamic voltage regulation �±5.0% for 10-80% or 80-10% load variation, regulation time < 50ms Rippel and noise, 30 MHz bandwidth < 500 mV PP Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug -in inrush current limiting, ORing diode
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
Supplier: Spices, car spare parts, textile, fittings, fruit & vegetables, machinery, medical equipments, electrical fitting, electrical modules, seimens, scneihder electric, abb, ge pipe fittings, pipes, steel, metal bars, plastics, copper, aluminium, footwear, glass, glassware, carpets, flooring materials, felt sheets woven, (pool cloths)watch equipments, construction equipment, rubber bee belt, bearings skf
Services: Clearing agent , transportation , shipping , courier , packaging
Rectifier Huawei R4850N2 is a digital rectifier that converts the 85~300VAC to 53.5 VDC and possesses the characters of high efficiency, high power density, walk-in start, hot-plug, complete protection, and low noise. The rectifier adopts the latest power monitoring technology, implements the function of monitoring the states of loads and the rectifier status in real time. The output voltage of the rectifier can be adjusted through the host.
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors