Do sensor dissolved oxygen sensor water quality control sensor kds-25b Model number: kds-25b Description The gs yuasa dissolved oxygen sensor kds-25b is a unique Galvanic cell type sensor which was developed for water quality Control. Its most notable features are long life expectancy and it Is not influenced by co2. Features: * long life * virtually no influence from co2 * no external power supply required for sensor Operation * no warmup time is required Applications: * water quality control
GS Yuasa Dissolved Oxygen sensor KDS-25B Features: * Long life * Virtually no in�uence from CO2 * No external power supply required for sensor operation * No warmup time is required Applications: * Water quality control The GS Yuasa Dissolved Oxygen Sensor KDS-25B is a unique galvanic cell type sensor which was developed for water quality control. Its most notable features are long life expectancy and it is not influenced by CO2. Specification: Measurement range: 0~80mg/L dissolved oxygen Accuracy in water at 25'C±1'C: ±5% (full scale) Operating conditions Atmospheric pressure: 81~203kPa (corresponds to 10m of water depth) Temperature: 5~35'C Relative humidity: 10 ~ 90%R.H. (no condensation) Thermal time constant: 10 min. or less Initial output voltage in clean air under standard test conditions: 8.0~15.0mV Standard test conditions Atmospheric pressure: 1013±5hPa Temperature: 25'C±1'C Relative humidity: 60±5%
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
1.Name: Sodium nitrate Chemical formula: NaNO3 Formula weght:84.99 2.Property: (1) ordinary sodium nitrate: white little crystals or light yellow (2) dry powder sodium nitrate: non-caking, showing loose status. Density:2.257. It is liable to deliquesce, dissolved in water, soluble in liquid ammonia, slightly soluble in ethanol and glycerin, Melting Point:308. While being heated up to about 380 it will decompose and release oxygen and turn into sodium nitrite,as the heating goes on, it will decompose into oxygen, nitrogen and nitrogen oxide. It has strong oxidability and can cause combustion explosion if being mixed with organic substance, sulfur, sodium nitrate etc. 3. Usage:Â it has been wildly used in the glass industry, dye, dynamite, metallurgy, machinery, ceramic etc. 4. Specification: (Technical Standards:GB/T4553-2002) Item Unit High G. First G. Qualified G. Dry powder G. Assay % 99.7 99.3 98.5 99.3 Sodium nitrite % 0.01 0.02 0.15 0.02 Chlorides % 0.25 0.30 -- 0.25 Water insolubles % 0.03 0.06 -- 0.03 Moisture % 1.0 1.5 2.00 0.2 Carbonates % 0.05 0.10 -- 0.1 Iron % 0.005 -- -- 0.005 Loose degree -- -- -- 95 5.Package: net 25kg/50kg net each in plasic woven inner plasic bag,or 500kg net each in flexible container.
Apple : Apple is beauty to share, both to lose weight, but also make the skin smooth and soft. Apple is a low-calorie food, every 10 green apple 0 grams only produce 60 kcal calories; apple nutrient soluble, easy to be absorbed by the body, it is "living water," said, is conducive to dissolving sulfur elements, so that the skin lubrication soft The There are copper, iodine, manganese, zinc, potassium and other elements, the human body such as the lack of these elements, the skin will dry, easy to crack, itchy. Vitamin C in the apple is the protective element of the cardiovascular, the health element of the heart disease. Eat more apples than those who do not eat or eat less apples cold risk is lower So, there are scientists and physicians called the apple "all-round health fruit" or called "general practitioner". Air pollution is more serious, eat apples can improve the respiratory system and lung function, protect the lungs from the dust and dust in the air.
With a Freestyle Libre Sensor you can continuously measure your blood sugar for 14 days. Attaching the sensor using the sensor applicator is well described in the instructions for use. When attaching the sensor, a small, 5mm long, flexible cannula is placed under the skin (usually painless). The sensor is worn on the back of the upper arm and continuously measures your glucose levels. It is waterproof and can be worn while bathing, showering or swimming. If you set up additional optional alarms, you will be warned in good time about hypoglycemia, for example, and can therefore feel even safer - day and night.
Gillette Fusion5 men's razor blade refills each have 5 precision blades spaced closer together (vs. Mach3) for less feel of irritation and incredible comfort. Each blade refill also has a Precision Trimmer on the back, great for edging tough areas such as under the nose and sideburns. One razor blade refill equals up to one month of shaves. These Fusion5 blade refills can be used with any Fusion5 razor handle. Features include: 5 precision blades, helping reduce pressure per blade for a comfortable shave (vs. Mach3) Precision Trimmer on back great for edging tough areas (nose and sideburns) 1 razor blade refill equals up to one month of shaves Fits with any Fusion5 blade refills
Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass.
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Reliable galvanic sensing technology Compact 12mm design For portable, laboratory or on-line use Optional integral atc element Easy to use pre-membraned replacement caps The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 laboratory dissolved oxygen sensor specifications Range: 0-20 mg/l Body material: epoxy and noryl Max temperature: 50 degrees c Saturation output: Hdpe = 47mv +/- 9mv, Ptfe = 33mv+/-9mv Pressure: 0-100 psig (7.5 bar) Calibration: single point in air Response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
WQ401 Dissolved Oxygen Sensor Description WQ401 Dissolved Oxygen Sensor is a rugged and reliable water oxygen measuring device. The WQ401's sensor is attached to 25 ft of marine grade cable, with lengths up to 500 ft available upon request. The sensor's output is 4-20 mA with a three wire configuration. The sensor's electronics are completely encapsulated in marine grade epoxy within a stainless steel housing. The unit uses a removable shield and dissolved oxygen element for easy maintenance. WQ401 Dissolved Oxygen Sensor Features * Measure dissolved oxygen in situ * Fully encapsulated electronics * 4-20 mA output * Marine grade cable with strain relief * Stainless steel housing * Replaceable dissolved oxygen element WQ401 Dissolved Oxygen Sensor Applications Ideal for stream and lake monitoring, aquaculture studies, baseline analyses, mitigation monitoring, and other environmental applications. WQ401 Dissolved Oxygen Sensor Specifications * Output: 4-20 mA * Range: 0 to 100% saturation, 0 to 8 ppm, temperature compensated to 77'F (25'C) * Accuracy: ±0.5% full scale * Maximum Pressure: 40 psi * Operating Voltage: 10 to 36 VDC * Current Draw: 15.5 mA plus sensor output * Warm-up Time: 10 seconds minimum * Operating Temperature: -40 to +131'F (-40 to +55'C)
OPTOD Optical Dissolved Oxygen & Temperature Sensor Optical technology: The OPTOD sensor is based on luminescent optical technology and is approved by the ASTM International Standard Method D888-05. Without calibration requirements, and thanks to an ultra low power technology, the OPTOD sensor is suitable for field work as well as long and short term monitoring. With no oxygen consumption, this technology gives an accurate measure in all situations, even in very low oxygen concentrations. Digital Technology: The "smart" OPTOD sensor stores calibration and history data within the sensor. This allows you a "plug and play" system without re-calibration. Digitally optimised measurement technology * Optical luminescence technology requires minimal maintenance * Digital sensor: Modbus RS-485 * No calibration required and therefore little to no drift occurs * Robust and Watertight OPTOD Optical Dissolved Oxygen & Temperature Sensor Applications * Industrial effluent treatment * Urban waste water treatment * Surface water monitoring * Drinking water OPTOD Optical Dissolved Oxygen & Temperature Sensor Specifications * Measurement ranges: 0.00 to 20.00 mg/L * Resolution: 0,01 * Accuracy: +/- 0.1mg/L, +/- 0.1 ppm, +/- 1 % * Response time: 90% of the value in less than 60 seconds * Temperature compensation: Via CTN * Operating temperature: -10°C to +60'C * Signal interface: Modbus RS-485 (standard) and SDI-12 (option) * Sensor power-supply: 5 to 12 volts
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Do1200 dissolved oxygen sensor features * reliable galvanic sensing technology * compact 12mm design * for portable, laboratory or on-line use * optional integral atc element * easy to use pre-membraned replacement caps Do1200 dissolved oxygen sensor description The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 dissolved oxygen sensor specifications * range: 0-20 mg/l * body material: epoxy and noryl * max temperature: 50 degrees c * saturation output: hdpe = 47mv +/- 9mv, ptfe = 33mv+/-9mv * pressure: 0-100 psig (7.5 bar) * calibration: single point in air * response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
We Can Supply Freestyle Libre 2 Flash Glucose Monitoring System Sensor Please Dont Hesitate to Contact Us in Case of Any Interested
Food meat smoker oven machine cooking ,drying ,baking ,fumigation ,exhaust,cleaning and other functions. The fast and slow cycle procedure can be selected according to the process requirements to achieve the best cycle and smoke effect .2.can monitor the smoke temperature,prevent the temperature is too high ,safe and sanitary .3.various types of temperature sensors are available for users to choose. 4.add water circulation cleaning device . capacity 50-1000kg
Wq-fdo optical dissolved oxygen sensor description The wq-fdo optical dissolved oxygen transmitter is an instrument designed for measuring dissolved oxygen concentrations in liquids. The wq-fdo optical dissolved oxygen transmitters were developed to meet different requirements ranging from surface water monitoring programs to harsh waste water applications. The optical dissolved oxygen transmitter has been specifically designed to meet the demanding requirements of the environmental monitoring and scientific research sectors, providing long term, accurate and reliable dissolved oxygen measurement. The wq-fdo optical dissolved oxygen transmitter has extremely low power requirements and a 4-20 ma output making it ideal for incorporation into remote environmental monitoring installations. Wq-fdo optical dissolved oxygen sensor features * extremely fast and precise optical do sensor - outstanding for field and lab applications * proven green light technology for long operation life of sensor * beveled membrane repells interference that can be caused by air bubbles * universal protective armoring available * low power consumption and low maintenance * simple to integrate and operate * one year sensor life Wq-fdo optical dissolved oxygen sensor applications Long and short term monitoring for streams, rivers, lakes, aquaculture, thermocline profiling, industrial outfalls, wastewater, scientific research, homeland security, the food and wine industry, and more. Wq-fdo optical dissolved oxygen sensor specifications * dissolved oxygen accuracy: â± 0.5 % of value * dissolved oxygen repeatability: 0.01 ppmâ?? * temperatureâ?? accuracy: â±0.2'f (â±0.1'c)â?? * temperatureâ?? resolution:â?? 0.02'f (0.01'c)â?? * temperatureâ?? range: 32 to 122'f (0 to 50'câ?? * max pressure: 35 psi (25m/82ft water depth)â?? * operating voltage: 10-30 vdcâ?? * warm up time: 6 sec. Min, 8 recommendedâ??
Y504-a dissolved oxygen sensor description The sensor is based on optical fluorescence lifetime quenching technique. Its technical procedure meets astm d888-09 standard for optical sensing of dissolved oxygen. This online sensor is developed to integrate with yosemite wireless monitoring system. Its rugged design and large measurement range make it ideal for sampling, flow cell, ground water and waste water measurements. Y504-a dissolved oxygen sensor applications Fish farmer, waste water plant, river, stream, and ocean monitoring Y504-a dissolved oxygen sensor feature , 0-20mg/l or 0-200% saturation , 0~50'c; ip68 rating , membraneless, no electrodes design , no oxygen consumption , flow independent , automatic temperature compensation , no h2s interference , low drift, fast response, and more accurate , low maintenance, low operating cost , easy sensor cap replacement , rs-485; modbus protocol compatible Y504-a dissolved oxygen sensor technical specifications , range, : 0-20mg/l or 0-200% saturation, , response time: 10 sec , housing ip rating: ip68, , accuracy: 1%, , drift:
Rdo-200 fluorescence dissolved oxygen sensor application Widely used in online dissolved oxygen monitoring for power plant, chemical, industrial wastewater, pharmaceutical, biochemical and water treatment industry. Rdo-200 fluorescence dissolved oxygen sensor feature * 0-20mg/l or 0-200% saturation * 0 ~ 50'c; ip68 protection rating * no film, no electrolyte, not polarization * no consumption of oxygen, the flow rate is not affected * built-in temperature sensor, automatic temperature compensation * chemical interference from sulfide * in drift, fast response, more accurate measurements * maintenance-free longer applicable period, lower cost * fluorescent cap replacement is simple * supports rs-485, modbus protocol Technical instructions Do range: -20mg/l 0-20 mg/l or 0-200% saturation Reaction time: 10 sec Degree of protection: ip68 Do accuracy±1% Sensor drift:
Submersible galvanic dissolved oxygen sensors Item no.: do6400/h, do6400/t, do6400tc/h, do6400tc/t, do6441/t, do6442/t, Do7400/h, do7400/t, do7400tc/h, do7400tc/t, do7441/t, do7442/t Large solution capacity for long term deployment Models with and without temperature sensor Easy installation and maintenance Mv or 4-20ma output models available The do6400 & 7400 series dissolved oxygen sensors feature a large capacity electrolyte holder, positive fit, easy to replace membrane and dependable galvanic cell technology for long term deployment. The body design ensures a good grip when wet. Ideal for aquaculture and wastewater monitoring applications, these sensors require minimal maintenance. Ptfe or high-density polyethylene (hdpe) membranes are available. 2 replacement membranes, installation tool and electrolyte are included. Additonal maintennace parts are in convenient kits (see ordering information). Sensors with mv output as well as built-in 4-20ma output in 0-100% and 0-200% saturation range are available. Dissolved oxygen sensors specifications O2 measuring range: Do6400, do6400tc (0.5-20ppm), do6441(0-100%), do6442(0-200%) Do7400, do7400tc (0.03-20ppm), do7441(0-100%), do7442(0-200%) Body: material noryl Cathode: silver Anode: zinc (do6400 series), lead (do7400 series) Maximum temperature: 50 degrees c Power requirement: 12-36v dc (for models do6441, do6442, do7441 and do7442 only )