Product Details: Number of Reactions(Preps)/Kit 20T Brand Abbott Result Time (Rapid Kits) 10 -20 min Sample Material Fecal Cat. No 14FK10 Bioline* Rotavirus test is an immunochromatographic assay for the detection of Group A rotavirus in human fecal specimens. The test utilizes two kinds of antibody in a solid phase sandwitch immunochromatography to detect group specific proteins, including the major inner capsid protein, present in Group A rotaviruses. Early detection of rotavirus antigen group A all serotype Shelf life and storage temperature: 18 months from the date of manufacturing at1-30 C Performance: Sensitivity : 94 %, Specificity 98.3 % (vs. RT-PCR)
Cat No :14FK10 Bioline* Rotavirus test is an immunochromatographic assay for the detection of Group A rotavirus in human fecal specimens. The test utilizes two kinds of antibody in a solid phase sandwitch immunochromatography to detect group specific proteins, including the major inner capsid protein, present in Group A rotaviruses. â?¢ Early detection of rotavirus antigen group A all serotype Shelf life and storage temperature: 18 months from the date of manufacturing at1-30 C Performance: Sensitivity: 94 %, Specificity 98.3 % (vs. RT-PCR)
Bioline helps the plant development by increasing the water holding and ventilation qualities of the soil. Bioline makes the soil’s structure which can be processed easily and causes the plant roots to penetrate in the soil easier. Bioline helps the soil grains to group and decreases the danger of erosion. Bioline decreases the shell layer formation on the top of the soil so increases the entrance of the water through the soil and decreases Surface flow. 25 kg powder / PP bags.
NUVO Famliy Anti Bacterial Hand Sanitizer contains active ingredients of 70% alcohol (ethanol) and moisturizer. The ethanol in this product can eradicate various types of germs (bacteria, viruses, or fungi), such as Escherichia coli, Staphylococcus aureus, influenza virus, herpes simplex virus, and rotavirus. Available in 3 Variants : - Cool Breeze - Fresh Blossom - Spring Nature Size: (1)Hand Sanitizer Gel : - pouch 36 x 50 ml, 24 x 85 ml, 12 x 250 ml, 12 x 1000 ml. - jerry cans 3 x 4 L (2)Hand Sanitizer Spay : - 6 psc/inner-box; 8 inner-box/box x 18 ml. - bottle 24 x 85 ml
General Information One-Step Rotavirus Rapid Test (Feces) is a rapid visual immunoassay for the qualitative presumptive detection of rotavirus in human fecal specimens. Sensitivity: 99.1% , Specificity: 99.9% Detection limit:103.5TCID50/ml Specimen: Feces Reading Time : 10min
50 % organic matter, 1 % nitrogen, pH 7-8 Powder compost. 25 kg / PP bags.
Product Details: Number of Reactions(Preps)/Kit 10 Brand Abbott Result Time (Rapid Kits) 15 mins Results 15 - 20 min Cat. No 11FK45 Bioline DENGUE DUO (DENGUE NS1 Ag + IgG/IgM)TEST FOR DENGUE INFECTION The Bioline Dengue Duo kit is a rapid, in-vitro immunochromatographic assay designed to detect both dengue virus NS1 antigen and IgG/IgM antibodies against dengue virus in human serum, plasma or whole blood. Bioline Dengue Duo rapid test contains two test devices (left side; Dengue NS1 Ag test, right side; Dengue IgG/IgM test). Benefits: Simultaneous detection of Dengue Ag & Ab Cover all clinical stages from acute phase to convalescence phase of infection Fast test result : 15~20 min Convenient storage condition : 1~30C Specification: Performance - Sensitivity : 92.4% (Dengue NS1 Ag), 94.2% (Dengue IgG/IgM) - Specificity : 98.4%(Dengue NS1 Ag), 96.4% (Dengue IgG/IgM)
Product Details: Number of Reactions(Preps)/Kit 30T Brand Abbott Usage/Application Hospital Result Time (Rapid Kits) 15 mins Cat. No 02FK10I30 Bioline HCVHEPATITIS C VIRUS TEST When speed matters, choosing a highly sensitive rapid HCV test with a safe fingerstick procedure can make a difference. In the global effort to eliminating viral hepatitis, fast detection in a wide range of settings and linkage to care are critical for achieving successful outcomes Bioline HCV test is a immunochromatographic rapid test for the qualitative detection of antibodies specific to HCV in human serum, plasma or whole blood. Specification: Specimen : - Serum, Plasma, Whole Blood (10 �¼l) for 02FK10, 02FK10CE, 02FK16, 02FK16CE, 02FK17, 02FK17CE, 02FK11 - Serum or Plasma (10 l) for 02FK12 Sensitivity : - 99.3% (95% CI: 97.9 - 99.8%) for 02FK10CE, 02FK16CE, 02FK17CE - 99.3% (95% CI: 96.1 - 99.9%) for 02FK10, 02FK16, 02FK17 - 100 % (97.6 - 100 %) for 02FK11, 02FK12 Specificity : - 100% (95% CI: 99.7 - 100 %) for 02FK10CE, 02FK16CE, 02FK17CE - 98.1% (95% CI: 94.5 - 99.4%) for 02FK10, 02FK16, 02FK17 - 99.4 % (98.7 - 99.7 %) for 02FK11, 02FK12 Shelf life: 24 months at 1-30C Qualitative immunochromatographic assay Recombinant HCV core, NS3, NS4, NS5 Ag used as capture materials
Product Details: Number of Reactions(Preps)/Kit 25 T Brand Abbott Result Time (Rapid Kits) 15-20 Min Cat. No 11FK50 Biolineâ?¢ DENGUE NS1 AgTEST FOR EARLY CLINICAL PHASE OF DENGUE INFECTION Bioline Dengue NS1 Ag rapid test is an in vitro immunochromatographic assay designed to detect Dengue virus NS1 antigen in human serum, plasma or whole blood. Product not available in all countries. Please check with your local sales representative regarding availability in your area. Benefits: Diagnosis of early acute dengue infection by detecting dengue NS1 antigen Dengue NS1 antigen can be detected from 1 day after onset of fever Specimen : Serum, plasma or whole blood (100l) Test result : 15~20 minutes Specification: Sensitivity 92.4%, Specificity 98.4%
Product Details: Number of Reactions(Preps)/Kit : 25T Brand : Abbott Usage/Application : Hospital Results : 15 min Sample type : Blood Cat. No : 08FK50 Bioline TB Ag MPT64TEST TO DISCRIMINATE BETWEEN M. TUBERCULOSIS COMPLEX AND MOTT(NTM) Bioline TB Ag MPT64 is a immunochromatographic identification test for the M. Tuberculosis complex. Biochemical, immunological and molecular biological characterization of Mycobacterium tuberculosis has led to the identification of several antigens which may be useful in the development of improved diagnostic methods in order to discriminate between the M. tuberculosis complex and mycobacteria other than M. tuberculosis (MOTT bacilli). M. tuberculosis has been known to secrete more than 33 different proteins. One of the predominant proteins, MPT64 was found in the culture fluid of only strains of the M. tuberculosis complex. Performance Sensitivity: 98.6 %, Specificity: 100 % (vs. Isolated culture method) Simple, rapid assay using mouse monoclonal anti-MPT64 Rapid discrimination between the M. tuberculosis complex and other mycobacterium Identification of the M. tuberculosis complex in combination with culture systems based on liquid media Specimen : Solid cultures (colony, condensation fluid) or liquid cultures Time to result : 15 minutes 1-30 C for 18 months
Cat No.02FK10I30. SD BIOLINE HCV test is an immunochromatographic rapid visual test for the qualitative detection of antibodies specific to HCV in human serum, plasma or whole blood Immobilized material: Recombinant HCV Core, NS3, NS4, NS5 Ag Specimen Type: Serum, Plasma, Whole blood Sample Volume: 10MuL Shelf Life: 24months Storage: 2-30oC Performance: Sensitivity: 99.5% and Specificity: 98% One Step Hepatitis C Virus Test.
Cat No : 11FK50. Bioline DENGUE NS1 Ag TEST FOR EARLY CLINICAL PHASE OF DENGUE INFECTION Bioline Dengue NS1 Ag rapid test is an in vitro immunochromatographic assay designed to detect Dengue virus NS1 antigen in human serum, plasma or whole blood. Product not available in all countries. Please check with your local sales representative regarding availability in your area. Benefits: Diagnosis of early acute dengue infection by detecting dengue NS1 antigen Dengue NS1 antigen can be detected from 1 day after onset of fever Specimen : Serum, plasma or whole blood (100�¼l) Test result : 15~20 minutes Specification: Sensitivity 92.4%, Specificity 98.4%
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : Abbott Product Type : Microplate Sample : Serum CAT. NO : 11EK50 The presence of circulating non-structural glycoprotein (NS1) indicates Viremia. If sufficient virus is present, NS1 can be detectable in a patientâ??s blood from day 0 to day 5 following disease onset. The detection of NS1 antigen is therefore useful as a test of early acute infection. â?¢ Early diagnosis of dengue infection High accuracy with all dengue serotypes (DEN1,2,3, and 4) Simple and easy to use: All necessary reagents included in the kit â?¢ Shelf life and storage temperature: 18 months from the date of manufacturing at 2-8 'C Performance: Sensitivity 93.3 % (87.4 - 96.6 %), Specificity 98.9 % (96.0 - 99.7 %)
Product Details: Number of Reactions(Preps)/Kit 25T Brand Abbott Time To Result 15 Min Result Time (Rapid Kits) 15 min Sample Type Blood Cat. No 05FK80 Bioline MALARIA Ag P.f/P.vTEST FOR PLASMODIUM FALCIPARUM AND PLASMODIUM VIVAX The Bioline Malaria Ag P.f/P.v test is a rapid, qualitative and differential test for the detection of histidine-rich protein 2 (HRP-2) antigen of Plasmodium falciparum and Plasmodium lactate dehydrogenase (pLDH) of Plasmodium vivax in human whole blood. BENEFITS Differential diagnosis between Plasmodium falciparum and Plasmodium vivax Useful for the region where P.v and P.f are both dominant Differentiate P.f mono infection from P.f/P.v co-infection WHO prequalified Specimen : Whole blood (5 l) Time to result : 15 minutes (up to 30 minutes) 1-40C for 24 months Performance: P.f (HRP2) : Sensitivity 99.7 %, Specificity 99.5% P.v (pLDH) : Sensitivity 95.5 %, Specificity 99.5%
Product Details: Brand Abbott Usage/Application Hospital Results 30 min Test Type Rapid Test shelf life 24 months Cat. No 05FK63I01 Bioline MALARIA Ag P.f/PanTEST FOR P.FALCIPARUM AND OTHER PLASMODIUM SPECIES The Bioline Malaria Ag P.f/Pan test is a rapid, qualitative and differential test for the detection of histidine-rich protein 2 HRP2 antigen of Plasmodium falciparum and common Plasmodium lactate dehydrogenase (pLDH) of Plasmodium species in human whole blood. Benefits: Distinguish P.f infection from other species (P.v, P.m or P.o) Useful in regions where all malaria species are circulating WHO prequalified Specimen : Whole blood (5 l) Time to result : 15 minutes (up to 30 minutes) 1-40C for 24 months Performance: - P.f (HRP2) : Sensitivity 99.7 %, Specificity 99.5 % - Pan (pLDH) : Sensitivity 95.5 %, Specificity 99.5 %
Product Details: Brand SD Country of Origin Made in India Specimen Serum Shelf Life 24 Months Temperature Storage 30 Degree Celsius Sensitivity 97.6% Specificity 98.0% H.Pylori Helicobacter pylori (H.pylori) is a spiral shaped bacterium and is found in the gastric mucous layer or adherent to epithelial lining of the stomach. H.pylori causes more than 90% of duodenal ulcers and up to 80% of gastric ulcers. Approximately two thirds of the world's population is infected with H.pylori. The immuno- chronomatographic techinques for the detection of antibodies specific to H.pylori has substantially resolved these problems. General Information: SD BIOLINE H.pylori test is a rapid test for the qualitative detection of antibodies of all isotypes (IgG, IgM, IgA etc) specific to Helicobacter pylori in human serum plasma or whole blood. Detection of all isotype (IgG, IgM, IgA) antibodies against H.pylori High Accuracy Sensitivity: 95.9%, Specificity: 89.6% Specimen: Serum. Plasma, Whole blood Material provided with this kit are as follows: SD BIOLINE H.pylori test device multi-device Assay diluent
Product Details: Brand : Abbott Package type : Microplate Pack size : 96wells/Kit Specimen : Serum Description : Dengue IgM Capture ELISA Cat.No. : 11EK20 Bioline DENGUE IgM CAPTURE ELISA In primary infection with the dengue virus, IgM antibody becomes detectable about five days after disease onset, when circulating virus declines in the blood. IgM level rises quickly to peak at about 2 weeks and declines to undetectable levels after 2-3 months In secondary infections, IgM response is typically at a lower level compared to that in a primary infection. Early diagnosis of dengue infection (especially in primary dengue infection) High accuracy with all dengue serotypes (DEN1,2,3, and 4) Simple and easy to use: All necessary reagents included in the kit Shelf life and storage temperature: 18 months from the date of manufacturing at 2-8 C Included in the WHO Bulk Procurement Scheme Performance: Sensitivity 96.4 %, Specificity 98.9 % (vs. HAI test).
Product Details: Usage/Application Hospital Time To Result 5-10 min SD BIOLINE Strep A rapid test is a chromatographic immunoassay for the qualitative detection of group A streptococcal antigens directly from throat swabs or confirmation of presumptive Group A Streptococcal colonies recovered from culture. Detection of strep-A antigen directly from throat swab Easy to use: throat swab sample Optimal test for Group A streptococcal infection. Ordering Information Cat No. Description Specimen Pack Size 45FK12 Strep A Group A Throat swab 25 Tests Streptococcal Ag
Product Details: Usage/Application Hospital shelf life 18 months SD BIOLINE Syphilis 3.0 test is a solid phase immunochromatographic assay for the qualitative detection of antibodies of all isotypes (IgG, IgM, IgA) against Treponema pallidum (TP). Specimen: Serum, Plasma, Whole Blood Sample Volume: 10MuL Serum / Plasma and 20MuL Whole blood Recombinant TP, 15kDa, 17kDa antigens used as captures and detectors The optimal choice for mass screening program No need preprocessing and equipments Storage: Room temperature (2-30 degree C) Performance: Sensitivity: 99.3% Specificity: 99.5% One Step Syphilis Antibody Rapid test Ordering Information Cat No. Description Type Pack size 06FK10I50 SD Bioline Device 50 Tests Syphilis 3.0
Product Details: Usage/Application Hospital Time To Result 15 Min Method Rapid Shelf Life 24 Temperature 1-40C The SD BIOLINE Malaria Ag P.f/Pv test is a rapid, qualitative and differential test for the detection of histidine-rich protein II (HRP-II) antigen of Plasmodium falciparum and Plasmodium lactate dehydrogenase (pLDH) of Plasmodium vivax in human whole blood. Specomen: Whole blood Time to result: 15 -30 minutes Storage: 1-40 degree C for 24 months Performance: Sensitivity: Pf-99.7%, Pv-95.5% Specificity: 99.5 % Optimal screening test for Plasmodium falciparum and Plasmodium vivax Ordering Information Cat No. Description Type Pack size 05FK80I40 SD Malaria Device 40 Tests