Product Details:
Brand : Abbott
Package type : Microplate
Pack size : 96wells/Kit
Specimen : Serum
Description : Dengue IgM Capture ELISA
Cat.No. : 11EK20
Bioline DENGUE IgM CAPTURE ELISA
In primary infection with the dengue virus, IgM antibody becomes detectable about five days after disease onset, when circulating virus declines in the blood. IgM level rises quickly to peak at about 2 weeks and declines to undetectable levels after 2-3 months In secondary infections, IgM response is typically at a lower level compared to that in a primary infection. Early diagnosis of dengue infection (especially in primary dengue infection) High accuracy with all dengue serotypes (DEN1,2,3, and 4) Simple and easy to use: All necessary reagents included in the kit Shelf life and storage temperature: 18 months from the date of manufacturing at 2-8 C Included in the WHO Bulk Procurement Scheme Performance: Sensitivity 96.4 %, Specificity 98.9 % (vs. HAI test).
Product Details: Number of Reactions(Preps)/Kit : 96 wells Brand : Abbott Usage/Application : Hospital Sample Material : Serum CAT No : 11EK10 The Panbio Dengue IgM Capture ELISA is used to detect IgM antibodies to dengue antigen in serum as an aid to clinical laboratory diagnosis of patients with clinical symptoms consistent with dengue fever. The Panbio. Dengue IgM Capture ELISA should be used in conjunction with other dengue serology.
Product Details: Number of Reactions(Preps)/Kit : 50 Brand : SD ICMR Approved : Yes Result Time (Rapid Kits) : 15 min Sample Type : Oral & Nasal Swab STANDARD E Dengue IgM ELISA analyzes IgM antibodies specific to Dengue virus in serum and plasma using enzyme linked immunosorbent assay.
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : Abbott Product Type : Microplate Sample : Serum CAT. NO : 11EK50 The presence of circulating non-structural glycoprotein (NS1) indicates Viremia. If sufficient virus is present, NS1 can be detectable in a patientâ??s blood from day 0 to day 5 following disease onset. The detection of NS1 antigen is therefore useful as a test of early acute infection. â?¢ Early diagnosis of dengue infection High accuracy with all dengue serotypes (DEN1,2,3, and 4) Simple and easy to use: All necessary reagents included in the kit â?¢ Shelf life and storage temperature: 18 months from the date of manufacturing at 2-8 'C Performance: Sensitivity 93.3 % (87.4 - 96.6 %), Specificity 98.9 % (96.0 - 99.7 %)
Product Details: Number of Reactions(Preps)/Kit : 96wells Brand : Abbott Cat. No : 01PE10 The Panbio Dengue IgG Capture ELISA is used to detect elevated IgG antibodies to dengue virus (serotypes 1-4) in patients with secondary infection. This test is intended as an aid in the clinical laboratory diagnosis.
The EV3 SpiderFX is commonly associated with the SpiderFX Embolic Protection Device, which is used in the field of interventional cardiology. The device is designed to capture and remove embolic debris that may be released during certain vascular procedures, particularly during carotid artery stenting. Key features of the EV3 SpiderFX Embolic Protection Device may include: Embolic Protection: The primary function of the device is to provide protection against embolic debris dislodged during the intervention. It helps prevent these debris from reaching and potentially blocking smaller blood vessels. Flexible Design: The SpiderFX typically has a flexible design that allows it to navigate through blood vessels, facilitating the deployment and retrieval process. Distal Protection: The device is designed to be positioned distal to the treatment site, capturing any embolic debris before it can travel downstream. Capture Basket: The device often includes a capture basket that traps and retains embolic debris, preventing it from causing harm in the circulation. Compatibility: The SpiderFX device is designed for compatibility with various catheters and guide wires commonly used in interventional procedures.
A "Roth Net Retriever" suggests a medical device used for retrieving objects or specimens, possibly in the context of endoscopy or minimally invasive procedures. The "POLYP 230CM" part of the description indicates a potential length of 230 centimeters, which could refer to the overall length of the device. Here are some general considerations: Usage: The Roth Net Retriever is likely designed for capturing or retrieving tissue samples, polyps, or foreign bodies during endoscopic procedures. Length: The specified length of 230 centimeters could be relevant for reaching and maneuvering within the gastrointestinal tract during endoscopy. STERIS: As a company known for providing healthcare solutions, the product may be designed to meet high standards of quality and hygiene.
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Bran : CTK BioTech Sample Material : serum or plasma Storage : 2-8 C Cat. No : AE0310 The Dengue IgM ELISA Kit is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of IgM anti-dengue viruses (DEN1, 2, 3, 4) in human serum or plasma. It is intended for professional use only as an aid in the diagnosis of acute infection with dengue viruses. TEST PRINCIPLE: The Dengue IgM ELISA Kit is a solid-phase enzyme-linked immunosorbent assay based on the principle of the capture immunoassay methodology for the detection of IgM anti-dengue virus in human serum or plasma. The Dengue IgM ELISA Kit is composed of two key components: 1) Solid microwells pre-coated with mouse monoclonal anti-human IgM antibody. 2) Conjugate working solution composed of dengue antigen and HRP-anti-dengue conjugates. During the assay, the test specimen is first incubated in the coated microwell. IgM antidengue, if present in the specimen, binds to the anti-human IgM antibodies coated on the microwell surface, and any unbound specimen is then removed by a wash step. During a second incubation with HRP-anti-dengue conjugate working solution, the IgM anti-dengue absorbed on the surface of microwell binds to the conjugate through dengue antigen, forming a conjugate complex. Unbound conjugates are then removed by washing. After addition of the TMB substrate, the presence of the conjugate complex is shown by development of a blue color resulting from a reaction between the enzyme and substrate. This reaction is then quenched by addition of the Stop Solution, and the absorbance value for each microwell is determined using a spectrophotometer at 450/620-690 nm. Accuracy of Detection : A total of 491 patient specimens were collected from susceptible subjects and tested by Dengue IgM ELISA Kit and by a commercial leading brand EIA. Relative Sensitivity: 90.8% (95% Confidence Interval = 85.5 - 94.4%) Relative Specificity: 95.9% (93.1 - 97.7%) Overall Agreement: 94.1% (91.6 - 95.9%).
Product Details: Number of Reactions(Preps)/Kit : 96 wells Brand : SD Biosensor ICMR Approved : Yes Result Time (Rapid Kits) : 1hr 40 mins STANDARD E Dengue IgM ELISA analyzes IgM antibodies specific to Dengue virus in serum and plasma using enzyme linked immunosorbent assay. Simple and easy to use - All necessary reagents included in the kit Highest accuracy with all dengue serotypes(DEN1,2,3, and 4) Performance Sensitivity : 97.4% (77/79) / Specificity : 96.6% (346/358)