Introduction The LWâ?¡-252/4000-50 self-extinction Ac circuit breaker which is outdoor type finds its universal range of applications for the electrical system with elevation not greater than 2000m, ambient temperature not lower than-30C, dirtiness grade not higher than IV, alternating current 50Hz and the maximum voltage 126kV. It is used for cutting the rated current, malfunction current or switching the circuitry, to control and protect the electrical system, and it can also be used for connecting with the circuit breaker The gas of the SF6 is employed as the arc-extinguishing medium and the dielectric material. The self-extinction technology and the new-type spring operating mechanism are introduced in the SF6 circuit breaker. Thus the circuit breaker has good qualities with long electrical life, low operation power, lower noise, high reliability, simple structure, small and long overhaul periods. It can fully replace the import same type one. Caracteristic of structure The breaker introduces the three-phase porcelain -pole with single interrupter structure. A spring operating mechanism is supplied and the mechanical action of the three-phase is inner connected. The gas of the SF6 is connected in the three-phase pole parts. A density controller with temperature compensation is used to monitor the gas of the SF6. Because of the self-extinction arc control principle and optimized design, it improves the efficiency of mechanism and reduces the operating power Excellent breaking performance and long electrical life High mechanism reliability and can be operated frequently Because of the high insulation intensity and excellent contact movement, the breaking capacity current will not re-burn The circuit breaker has high outer insulation level and ratio creepage distance is greater than. So it has excellent performance of resisting the filth and the earthquake, it is also can be operated safely under the environment with atrocious weather High carrying ability: it has high capability margin as the temperature of each contact rises when it is under temperature rise test in the circuit (1.2 times 0f 4000A) The appearance of the breaker is compact, and the installation and debugging is very easy. The maintenance is also very convenient
Circuit breakers Lw-252 high voltage sf6 circuit breaker type Lw8a-40.5 outdoor porcelain post hv sf6 circuit breaker Lw36-126 high voltage sf6 circuit breaker Zn28-12 series indoor ac medium-voltage vacuum circuit breaker Zn63a-12 series indoor ac medium-voltage vacuum circuit breaker Nv1-24 series indoor ac high-voltage vacuum circuit breaker 252kv gis Lw3-12 outdoor ac medium-voltage sf6 circuit breaker Zw8-12 series outdoor ac medium-voltage vacuum circuit breaker Zw8-12(z) series outdoor intelligent ac mv vacuum circuit breaker Zw32-12 outdoor ac hv vacuum circuit breaker
HVD8 /LW8-40.5 type outdoor high-pressure sulfur hexafluoride circuit breaker is three-pole ac 50 hz, outdoor high voltage switch equipment, applicable to 40.5 kV power transmission and distribution system control and protection, can also be used to contact circuit breaker and movable capacitor group.
Led bulb, tube light, panel light, decoration light, wall light, steel wires, steel plate, stainless steel plate, twisted wire rods, galvanized wires, wire mesh, site fencing, mosquito mesh, thread rods, rebar, twisted rods, t bar, nuts and bolts, hardware, pvc pipes, upvc pipes, api pipes, melamine, mdf board, plywood, film faced, shuttering, packing, core veneer, face veneer, hdf molded door skin, door filler, tubular particle boards, pvc boards, wpc boards, doors, block board, hard board, gypsum board, canopy, carpet, flooring wooden, bamboo, laminated engineering, tiles, granite tiles, granite blocks, black galaxy, wash basin, water closets, washbasins, ss sinks, faucets, furniture, pvc edge bending, crew, locks, pvc seals, silicone cartridges, shower enclosures, shower door hinges, handles, knobs, brackets, slides, nails, solar panels, flexible solar panels, solar power station, battery, inverters, rechargeable fans, lights, spring, 3ply disposable face mask, oxygen concentrator ,.Buying office, oem, components sourcing, value added services
DZ47 AC MCB circuit breaker series is used in lighting distribution system or motor distribution system for protecting overload and short-circuit condition. The product is light in weightreliable and excellent in performance. It has high breaking capacity up to 6kA. Its case and items are adopted with high fire-resistant and shock proof plastics. Mainly used in AC 50/60Hz single-pole 230V or two three four-pole 400V circuit for overload and short circuit protection as well as for on-off switching electric equipment and lighting circuit. The product complies with EN/IEC60898. Rated current(In) 1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A ,32A ,40A, 50A, 63A, 100A Optional Rate voltage(Un) 230VAC / 415VAC / 400VAC / 415VAC Optional Breaking capacity 6kA Rated frequency 50/60Hz Tripping charateristics BCD Number of poles 1P, 2P, 3P, 4P, 1P+N, 3P+N Optional Rated impulse withstand voltage(Uimp) 4kV Electrical endurance 10000cycles Mechanical endurance 10000cycles Terminal Pillar type
WSD-ZW32-24D Outdoor AC high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is a rated voltage of 24 KV, 50 HZ three-phase AC outdoor distribution equipment.The utility model has the advantages of stable and reliable interruption performance, no danger of combustion and explosion, maintenance-free, small size, light weight and long service life.It is mainly used for breaking and closing the load current, overload current and short circuit current in power system.It is suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, and more suitable for rural power grids and frequently operated places. This product meets GB1984-2003 "High Voltage AC Circuit Breakers" and DL/T402-2007 "Technical Conditions for Order of High Voltage AC Circuit Breakers" and DL/T403-2000 "Technical Conditions for Order of 12 kV~40.5 kV High Voltage Vacuum Circuit Breakers" and other technical standards.
CHARACTERISTICS 1. The vacuum arc extinguishing chamber uses longitudinal magnetic field arc extinguishing technology, which has the characteristics of long electric life and high reliability. 2. The imported silicone rubber/epoxy resin for outdoor use and the present APG vacuum injection technology are adopted. 3. Anti-ultraviolet, moistureproof, anti-corrosion, with the advantages of preventing surface discharge, good hydrophobicity and high mechanical strength. 4. Using simple and reliable spring operating mechanism, it has the advantages of small size and light weight. 5. high voltage vacuum circuit breaker can be equipped with isolation switch and three-phase linkage. It has visible breaks when the isolation switch is switched off. It also has anti-mistake interlock between the isolation switch and the circuit breaker body. It can be equipped with arrester strut insulators. Operational sequence When operating the disconnector, the first step is to confirm that the circuit breaker should be in the open state. Use the insulated tie rod hook to fasten the closing pull ring or the opening pull ring of the operating handle of the isolation closure, pull down slightly, drive the spindle to rotate, open or close the isolation switch. When the spindle rotates the dead point position of the compression spring, a certain tension is maintained so that the blade can be reliably closed or opened to a safe isolation position.
S280 3 phase ac power circuit breaker is mainly used for special occasions where two main circuits can not work at the same time. To prevent the simultaneous closing of the circuit breaker, the product can switch the line safely and quickly. It realize the switching between stand-by power supply circuits and other protection functions. Iiâ??s mainly used in the overload protection and short-circuit protection of the circuit which is DC 50Hz/60Hz, 1 pole230v, 2/3/4 poles DC1000V.
C65 C60 mini circuit breaker AC MCB is used in lighting distribution system or motor distribution system for protection overload and short-circuit in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/60Hz single pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb Wattage: 10W Blue UV light Lumen: 900-1000lm Color Temperature (CCT): 6500K Input Voltage: AC 90-130V & 220v-240V With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Circuit breaker The circuit breaker mainly serves for protecting the circuits of ac 50 hz, 230vof single pole, 230v/400v of two poles and 400v of three or four poles from overload or short-circuit, and also for unfrequent making and breaking electrical apparatus and lighting circuit. Packed in export cartons
Standard rating: 1-20 ampere. Input power: 12 VDC /125 VAC / 250 VAC. Dielectric strength: 1500 VAC / 1 minute. Reset: manual push reset. Approvals: CSA, VDE, CSA C/US.
Terasaki, , square d, siemens, merlin gerin, qo, areva, sylvania, westinghouse, ge, murray, moeller, federal, schneider, zinsco, eta, cutler hammer, airpax, heinemann, klixon, hager. Miniature circuit breaker, air circuit breaker, electric circuit breaker, earth leakage circuit breaker, thermal magnetic circuit breaker, low voltage circuit breaker, molded case circuit breaker, vacuum circuit breaker, standard circuit breaker
Mini circuit breaker is suitable for wires of AC 50Hz, rated voltage of 400V,rated current of 32A(63A)D, with some protection functions such as leakage because of getting an electric shock, overload, short circuit, etc., and it can add over-voltage protection function according to users’ requirements. It mainly used in building lighting and protection of power distribution system. This product accords with IEC61009 and GB16917.1 standard.
DZ47-63 Series High Breaking Capacity Mini Breaker may be used in such occasions with AC 50 or 60Hz, rated working voltage of 415V or below and rated working current of 63A.It can servefor the illumination of office, residential housing and similar buildings and its distribution wires and protect the distribution circuit and equipment against overload and short-circuit.It can also be used for infrequent conversion of circuit under normal conditions. Rated current:1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Number of poles:1p, 2p, 3p, 4p Working voltage:From 240V to 415V DZ47LE Series Leakage Circuit Breaker may be used in the circuit with AC 50 or 60Hz, rated voltage of 230V or 400V and rated current of 63A or below. It can prevent personnel from electric shock, protect equipment against leakage and the circuit against overload and short-circuit It can also serve as infrequent conversion of circuit and infrequent startup operation of motor under normal conditions. Number of poles: 1p+n, 2p, 3p, 3p+n, 4p, Working voltage: 240V, 380/400V, 240V, 240/415V Rated current: 1A, 3A, 6A, 10A, 20A, 25A, 32A, 40A, 50A, 63A DZ20 series Moulded Case Circuit Breaker (hereafter refers to as circuit breaker) to be suitable to exchanges 50HZ. The nominal current from 16A to 1250A, fixed insulation voltage 660V, fixed working voltage 380V (400V) and in the below electric circuit makes the infrequent transformation and the electric motor infrequent starting using of. The circuit breaker has the overload, short-circuits and owes the voltage protective device, can protect the line and the power equipment is not damaged. This circuit breaker may be vertical the installment (namely vertical stroke to install), also may the level installment (namely horizontal attire). This circuit breaker carries out the standard: GB14048. 2 and IEC60947-2. Product model: Dz20-100, dz20-225, dz20-400, dz20-630, dz20-800, dz20-1250 Rated current: From 16A to 1250A Rated working voltage: 380V DZ30LE-32 Leakage Protector may be used in single-phase domicile circuit with AC 50 Hz or 60Hz, rated voltage of 220 V and rated current of 32 A. It can prevent personnel from electric shock, and protect vivil electric lines against overload and short-circuit. This product is of such characteristics as small volume, high breaking capacity and cutting off the live and zero lines at the same time. Rated current: 3A, 6A, 10A, 16A, 20A, 25A, 32A Number of poles: 1p+n Working voltage: 220V
Product Description Major Technical Data: Rated voltage: 12KV Rated frequency: 50HZ Rated current: 630A. 1250A. 1600A. 2000A. 2500A. 3150A. 4000A. 5000A. Rated short circuit current to be turn-off: 20KA. 31. 5KA. 40KA. 63KA. Mechanical lifetime of the operating device: í¦100, 000 times (5000A 63KA Mechanical lifetime: í¦60, 000 times) Mechanical lifetime: (630A-1250A) 20KA í¦50, 000 times. (1250A-3150A) 31. 5KA í¦50, 000 times (1250A-4000A) 40KA í¦30, 000 times (5000A) 63KA í¦30, 000 times Operating voltage for switch-on and switch-off: DC220V or AC220V. Model: ZN73A-12 Standard: ISO9001 CQC CCC.
DZ47-63 Miniature Circuit Breakers has small size, light weight, novel structure and excellent performance. The material of enclosure and inside plastically parts is fire resistance and withstand shocking. It is used in the circuit of 50/60Hz,rated voltage 230/400 V, rated current up to 100A as protection against overload and short circuit. It is also used as protection against frequent switchover.
Dimension for outline: Specification: 1.Rating currentú¦min.5Aú¼max.20A 2.Working pressureú¦min.12Vú¼max.250V 3.Double usage of DC and AC Application scopeú¦Used at the prote ction of compound outlet, power transformer and electrical motor. Current specificationú¦5A-15A125V UL
JD156(DZ47) series circuit breaker is used in Helmet distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50/60HZ single-pole 240 or two, three four-pole 415V circuit for overload and short-circuit protection as well as for unfrequented on íºCand-off switching electric equipment and Helmet circuit in normal case.