Quick information Brand name: feiniu Place of origin: china Model number : 07 Application : industrial Conductor material : aluminum Insulation material : pvc Jacket : pvctype : high voltage Description Electric power cable Electric power cables are used to transmit and distribute electricity, electric power cables commonly used in urban underground power grids, power plants lead the line, industrial and mining enterprises within the power supply and across the river underwater transmission lines. In the power lines, the propo rtion of c able is gradually increasing . The electric power cable is a cable product used to transmit and distribute high-power power in the main line of th
Forming fabric are designed to retain as much fiber components as possible, meanwhile allowing water to drain through them. Forming fabric can be divided into single, 1.5, double, 2.5, triple (SSB) layer. Which applicable to the machine speed up to 2000m/min. Forming fabric is characterized by smooth surface without edge curl, good stability and less elongation, unique drainage channel without leaking, good runnability with low load, good fiber support and excellent formation, good life potential
Model utp cat6 network cables 300m Conductor Material CCA/CCC/CU Conductor 4Pair 23AWG Conductor Dia. 0.5mm/0.52mm/0.54mm/0.56mm/0.57mm Insulation 1.PE 2.HD-PE (High density polyethylene) Insulation Dia. 1.024mm Cross Center Cross Center Shielding UTP/FTP/SFTP Ripcord Ripcord Jacket PVC,LSZH PVC Nom. Thickness(mm) 0.65mm Color Optional Fire Rating CMP,CMR,CM,CMG,CMX
The product is applicable to overhead power line with rated AC voltage of 10kV (12kV); Maximum long-term allowable working temperature is 90 Degrees Celsius; While installation,the ambient temperature should not be lower than minus 20 Degrees Celsius; When the core is in short circuit ( max 5 s ) the temperature should not exceed 250 Degrees Celsius.
This product is used for AC rated voltage of 300/300V electric appliance, instruments and meters, electronic equipment and automation device. Standards: GB5023-1997, which is equal to IEC227(1979) Models: AVP: Copper core PVC insulation shielded wire AVP-105: Heat-resistant 105 degrees Celsius PVC insulation shielded wire RVP: Copper core PVC insulation shielded flexible wire RVP-105: Heat-resistant 105 degrees Celsius PVC insulation shielded flexible wire RVVP: PVC insulation shielded PVC sheathed flexible wire RVVP1: PVC insulation entangled shielded PVC sheathed flexible wire
Its applicable to overhead line with AC rated voltage of 10/12kV. Maximum long-term allowable working temperature of conductor is 90 degrees Celsius. While the installation, the ambient temperature should not lower than minus 20 degrees Celsius. When the core is in short circuit (max 5s), the temperature should not exceed 250 degrees Celsius.
The wire is suitable for fixed installation of electrical equipment or lighting devices at AC rated voltage U0/U: 300/500V or lower. Models: BXF - Copper conductor rubber insulated/chloroprene rubber mixture sheathed power line BLXF - Aluminum conductor rubber insulated/chloroprene rubber mixture sheathed power line BX - Copper conductor rubber insulation cotton yarn or other similar fiber weaving power line BLX - Aluminum conductor rubber insulation cotton yarn or other similar fiber weaving power line BXR - Copper conductor rubber insulation cotton yarn or other similar fiber weaving flexible power line
Voltage 600V or less Construction The bare flexible stranded copper conductor is insulated with ethylene-propylene rubber (EPR). Two, three or four insulated conductors are cabled together with filler and sheathed with chlorinated polyethylene. Standard UL62, CSA 22.2, or other standards required by customers.
Voltage 450/750V or less Construction 1-core: The copper conductor is insulated with natural rubber and sheathed with natural rubber or chloroprene rubber multi-core: The copper conductor is insulated with natural rubber. Two to six insulated conductors are cabled together with extruded rubber filler, and sheathed with natural rubber or chloroprene rubber. Standard IEC 60245, GB/T 5013, or other standards required by customers. Features 1.Flexible and reliable. 2.Abrasion, corrosion, high-Heat and oil Resistant. Applications Sino cables type rubber cables are suitable for power supply to power appliances, home appliances and movable field electric equipment at 450/750V or less. Package Coil, Steel /Wooden Reel ,Wooden Reel or Steel Reel.
Voltage 600V or less Construction Sino-cables type covered line wire(ASTM) is manufactured with aluminum alloy 1350-H19, 6201-T81,or ACSR conductors insulated with low density PE, or high density PE or XLPE. Standard ASTM B230, B231, B232, B399, B498, or other standards required by customers. Applications Sino cables type covered line wire(ASTM) is primarily designed for use on overhead secondary distribution lines. Covered Line Wire is not an electrically insulated conductor and is treated as a bare conductor when installed. The insulation provides protection against circuit interruption due to weather. Package coil, steel/wooden reel, wooden reel or steel reel.
Voltage 450/750V or below Standard Q/320623 SQ 13-2009; GB/T 9330, or other standards required by customers. Features 1.high-heat resistant, low temperature, anti-aging, oil resistant. 2.all our wires are environmental-oriented, low smoke and low halogen, they are also can be fire retardant, fire resistant, or on customers needs. Applications Sino-cables type control cable is primarily used in controlling and monitoring the circuits especially in severe environment, connecting electrical meters in distribution equipments and conveying signals in automation systems, being widely used in power plant, oil, chemical, metallurgy, steel, sewage treatment, etc. Package in coil, steel and wooden reel, steel reel, wooden reel.
Voltage 600V or less Construction RHH or RHW-2 or USE-2 aluminum conductors are AA-8000 series Aluminum Alloy, compact stranded. Insulation is an abrasion, moisture, heat, and sunlight resistant black cross-linked polyethylene (XLP). Copper conductor is also available. Standard RHH or RHW-2 or USE-2 conductors meet or exceed UL Standard 44 (for RHH or RHW-2), UL Standard 854(for USE-2), Federal Specification A-A-59544, and requirements of the NEC. Or other standards required by customers. Features 1.-40----90 2.Abrasion, high-Heat and Moisture and Sunlight Resistant. 3.VW-1 or higher required by UL. Applications 1. RHH or RHW-2 or USE-2 conductors are used with conduit as specified in the NEC. 2. May also be used as underground service entrance cable, for direct burial, at conductor temperatures not to exceed 90. 3. When used as RHH, conductor temperatures shall not exceed 90 in dry locations. 4. When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90 in wet or dry locations. Package steel wooden reel, wooden reel, steel reel, in coils on wooden tray, or other requirements by customers.
Voltage 600v Construction Sino cables type soow is manufactured with bare flexible copper conductor insulated by ethylene-propylene rubber (epr). Two, three, four or five insulated conductors are cabled together with filler and sheathed with chlorinated polyethylene.
3 or 5 meters RRU to RCU RET AISG connector to DB9 Connector RET control cable Cable for Huawei RET Wireless Solutions Provider .......... Details: Connector 1: AISG Connector Connector 2: DB9 Connector Cable: 4 Pair 24 AWG Temperature Range: -40~80°C Waterproof: IP67 Single Band Radius: 60 Mm Min Multiple Band Radius: 120 Mm Min Rate Current: 4 A Packaging Details: sealed plastic bag, 50 pcs in a carton (17.5kg/carton)
Decorative Christmas wire / UL Wire Application: The lighting soft wire is used in outdoor for decorative , as well as can be used in household. Working conditions: Rated voltage:300V Rated temperature: 105°C Conductor can be single wire, standard wires or thinner soft copper wire Insulation material complies with the requirements of ROHS Wire has the flame test of ULVW-1 and CSA FT2
PVC Power Cable The cable is used to keep working for some time under fire cases on the power line of rated 0.6/1KV power transmission and distribution. The product is produced according to the standard of GB/T12706-2008, GB/T 19666-2005, GA306-2007, IEC0092-1994. Fire-resistance features comply with the provisions of GB/T 19666-2005, GA306 and IEC61643 331-2003.
Eco-pvc Insulated Electric Wire / Hook Up Wire The wire is used as connection wire of rated voltage 450/750V or lower for power plants ,fixed wiring and flexible connection for electrical appliances. Work Condition: Long-term Max. working temperature allowed by cable conductor 60227IEC(BV-90).................................................................90 60227IEC(RV-90).................................................................90 other type.............................................................................90 Environment temperature of laying should be not less than 0 Bending radius of cable D25mm ........................................4D D>25mm ..............................................................................6D (D is outer diameter of cable) Rated voltage U0/U is 450/750V,300/300V,300/350V
Copper Heat- Resistant PTFE Cable Application: It is used as connection for electronic devices and Electric appliances, and connection of inner circuit of instruments. Product Advantage: Small external diameter , Light weight, Good flexibility, Easy to weld, High temperature resistant, Anti-aging, Anti-interference
Photovoltaic cable / PV Solar Cable Application: Specifically designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements. Photovoltaic cables are usually exposed to sunlight and used in harsh conditions, such as high temperatures and ultraviolet radiation, so it has its special advantage of high temperature resistance and UV resistance. At the same time, PV cable should has resistance to dent, ozone, Weather, Acid and alkali corrosion.
Mining Cable Application: The cable is used to connect power supply of coal mining machine and similar equipment with rated voltage 1.9/3.3kv lower Work Condition: Rated voltage U0/U is 0.38/0.6kv, 0.66/1.14kv or 1.9/3.3kv Min. bending radius of cable is 6 times of cable's diameter The ground wire of cable should be connected well with ground