Alternating and direct current amphibious light AC DC Hipot Test Set. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on.
Stroboscope - BRAND - VIJAYANTA, INDIA 1. Stroboscope, Model: STB 01 For the measurement of shaft speed using stroboscope principle.
Potentiometer Error Detector - BRAND - VIJAYANTA, INDIA 1. Potentiometer Error Detector, Model: PED 01 To study the performance of a potentiometer type D.C. position error detector.
Linear System Simulator Trainer - BRAND - VIJAYANTA, INDIA 1. Linear System Simulator Trainer, Model: LSS101 To study the performance of First, Second and Third order Systems.
Magnetic Amplifier Demonstration Unit Various type - BRAND - VIJAYANTA, INDIA 1. Magnetic Amplifier Demonstration Unit, Model: M 1 1600 suitable for demonstrate all experiments based on magnetic amplifier principle. Capacity : 250, VA. Including : (i) Power Supply, Model-LV-30/1. (ii) AC/DC Ammeter, Range : 5 Amp. (iii) Rheostat, Range : 250 ohm / 1 Amp. 2. Magnetic Amplifier Demonstration Unit, Model: M â?? 1 â?? 1700 Suitable for demonstrate of Self excited, positive feedback & negative feedback, Amplest and Bridge Capacity : 250, VA. Including : (i) Power Supply, Model-LV-30/1. (ii) AC/DC Ammeter, Range : 5 Amp. (iii) Rheostat, Range : 250 ohm / 1 Amp. 3. Magnetic Amplifier Demonstration Unit, Model: M â?? 1 â?? 1800 Suitable for demonstrate of series connected, parallel connected & BH Loop. Capacity : 250, VA. Including : (i) Power Supply, Model-LV-30/1. (ii) AC/DC Ammeter, Range : 5 Amp. (iii) Rheostat, Range : 250 ohm / 1 Amp.
Dielectric Measurement Setup - BRAND - VIJAYANTA, INDIA 1. Dielectric Measurement Setup, Model: DEC-600 Suitable for temperature upto 600 C, including highly stable PID Controller and Capacitance meter 1pF to 20000F.
Dielectric Constant of Solids & Liquids - BRAND - VIJAYANTA,INDIA 1. Dielectric Constant of Solids & Liquids, Model: DSL-01 Dielectric measurements of nonconducting solids & liquids. Complete in all respect
Frequency Dependence of Dielectric Constant - BRAND - VIJAYANTA, INDIA 1. Frequency Dependence of Dielectric Constant, Model: FDD-10 (Comes with multiple samples. Optional temperature variation facility also available) Complete in all respect, except a CRO
Ionization Potential Set Up - BRAND - VIJAYANTA, INDIA 1. Ionization Potential Set Up, Model: IP-01 Measurement of lionization potential of Argon Gas. Complete in all respects, but a Oscilloscope will be helpful.
Magnetic Field Measurement Apparatus - BRAND - VIJAYANTA, INDIA 1. Magnetic Field Measurement Apparatus, Model: MFM 01 Study of the magnetic field of a current-carrying coil & determination of its radius. And Study of superimposition of magnetic fields generated by two coils at different positions. Complete in all respects.
Two Probe Method for Resistivity Measurement of Insulators at Different Temperatures - BRAND - VIJAYANTA, INDIA 1. Two Probe Method for Resistivity Measurement of Insulators at Different Temperatures, TPX 01 The Apparatus consists of the following Sub. Unit : (a) Two Probe Arrangements with built in RTD sensor, TPA TPX 01 (b) PID Controlled Oven, PID 200 (c) High Voltage Power Supply, EHT 11 (d) Digital Picoammeter, DPM 111 Complete in all respect.
Hall Effect in Bismuth - BRAND - VIJAYANTA, INDIA 1. Hall Effect in Bismuth, Model: HEX-100 Bi The set-up consists of following units : (a) Digital Gaussmeter, DGM-202 (b) Multipurpose Stand (c) Electromagnet, EMU-75 (d) Constant Current Power Supply, CCS-10 (e) Digital Microvoltmeter, DMV-01 (f) Constant Current Power Supply, CC-75 (g) Hall Probe for Bismuth If You Still Any Enquiry Please Feel Free And Contact Us.
Apparatus for the measurement of Susceptibility of Solid by Gouys Method Various Type, BRAND-VIJAYANTA, INDIA 1. Apparatus for the measurement of Susceptibility of Solid by Gouys Method. (with EMU 75 & CC 75), (suitable for different variety of samples), Model: GMX 01 2. Apparatus for the measurement of Susceptibility of Solids by Gouys Method.(with EMU 50 & CC 50),(suitable for classroom experiment), Model: GMX-01 The set up consists of the following units : (i) Scientific Balance (with weight box), KSB - 07 (ii) Al. Samples and Glass Tube for Powder samples (iii) Gouy's Balance Stand (iv) Digital Gauss Meter, DGM 102 (v) Electromagnet, EMU 50T (vi) Constant Current Power Supply, CC 50 3. Apparatus for the Measurement of Susceptibility of Solid by Gouy's Method, Model: GMX - 02. The set up consists of following units: (i) Digital Balance, CA - 44 (ii) Al. Samples and Glass Tube for powder samples (iii) Trolley (iv) Electromagnet, EMU 50T (v) Constant Current Power Supply, CC 50 (vi) Digital Gauss Meter, DGM 202
The transformer partial discharge detection device and the sensorwith the software using advanced signal processing technology covering a wide range of statistical methods and graphical display mode and coming with highenergy lithium batteries can flexibly achieve the detection of transformer partial discharge signals and ultrasonic signals capable of full range of detection for the transformer's partial discharge. Partial discharge detection location detect the partial discharge changes in the transformer's internal during the operation by examining the partial discharge conditions of the device to analyze the insulating state of the transformer. High frequency current transformers (pulsed current method) an ultrasonic sensor (ultrasonic method). Through a variety of means to suppress various external noise interference it improved signal to noise ratio and the measurement accuracy.
product features 1 The reactor of the same voltage grade and capacity has smaller volume and lighter weight. Small temperature rise at rated load; Dry pouring high mechanical strength good electrical insulation beautiful and reliable. 2 Large capacity margin of frequency conversion power control box; Strong protection function; Good output waveform; Good stability; With a variety of working modes easy to operate; Single-phase 220V or three-phase 380V input power supply is common which is convenient for on-site power collection. 3 Flexible configuration. Can choose different types of reactor meet the requirements of different test products achieve a multi-purpose cost-effective.
producing air disc brake caliper and repair kits with over15 years experiences. We have our own casting &forging plants, as an IATF 16949 certificated manufacturer, we guarantee the good quality control process , we have our own brand patents, technical center, machining centers, digital metal-working machines, brake assembly lines and test machines.
Mayo Hegar Needle Holder Tungsten Carbide 14 cm
Applications: Tests for current transformer: 1) Excitation curve and parameters test 2) Turns ratio test 3) Ratio and phase error test 4) Polarity mark check 5) Winding resistance measurement 6) Secondary loop burden measurement 7) Error line curve test for protection CT 8) Transient CT parameters test 9) CT nameplate guess 10) Saturation hysteresis loop curve measurement Tests for voltage transformer: 1) Turns ratio test 2) Ratio error and phase angle error test 3) Polarity test 4) Secondary burden test 5) Winding resistance test Features: 1. Make evaluation for test results according to selected standards. 2. Make word report for test result. 3. Make word reports one time for multi-group test records on the PC. 4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test. 5. Compare excitation curves with saved excitation curves in the same window.
Transformer Tester is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARMadvanced manufacturing technology ensure a stable and reliable product performance full-featured high degree of automation high efficiency in the domestic leading level they are the professional testing equipments for transformer check in power industry. Product names CT parameter analyzer CT analyzer frequency CT analyzer CTPT analyzer transformer tester frequency transformer characteristic tester transformer transient characteristic analyzer current transformer tester CT characteristics analyzer current transformer current transformer parameters analyzer features analyzer CT parameter tester tester current transformer current transformer parameters characteristics tester Comprehensive instrument for the transformer
Product Introduction Designed for automatic testing of protective and metrological CT/PT suitable for laboratory and field testing. The product names PT volt-ampere characteristic tester transformer volt-ampere characteristic integrated tester CT voltage-current characteristic integrated tester CT voltage-current characteristic tester PT volt-ampere characteristic tester transformer volt-ampere characteristic tester volt-ampere characteristics of variable polarity than integrated tester volt-ampere characteristic tester volt-ampere characteristics integrated tester volt-ampere characteristic tester features comprehensive tester