Thermostat control.
The Apollo touch screen room thermostat is mainly applied the Heat pump, Gas Heating, Electric Heating, and so on systems. Features: 24VAC or Battery Powered (2 x AAA) Large Backlit LCD Touch Screen Security Logic inc Key lock & Limit Control 7 day, 5+2 Day or Manual Operation Programmable Fan Logic Heat cool & Heat Pump Logic Single & Multistage Control Remote Sensor Inputs Outside Sensor Inputs Designed and built by Smart Temp Australia Comprehensive 3 year Warranty RTB Specifications: Input Voltage (Hardwired) 20-30 VAC 50/60 Hz Relay Rating 24 VAC @ 1 Amp Max Per Relay Battery Power (2) AAA 1.5 V Operating Temperature 0° C to 55° C Operating Relative Humidity 0-95% (non-condensing) Storage Temperature 0° C to 65° C Size: 125" W x 85" H x 25" D (mm) LCD Display Size 57 W x 99 H (mm) Back Light White LED Short-Cycle Delay Off or 4 minutes Displayed Temperature Resolution 0.1° C Set Point Range Heating 5° C - 49° C Cooling 6° C - 50° C Heating and Cooling Limits Fully adjustable Onboard Sensor NTC type 3 100K Remote NTC type 3 10K Warranty 3 years (RTB).
Thermocouples are manufactured in many different configurations for multitude of applications. Diameters, lengths, sheath material, lead lengths and sensor material are just a few of the variables that go into determining the style of thermocouple when manufactured. The main determining factors of what type thermocouple needs to be used in a application is temperature, environment, response time and accuracy. The junction of the thermocouple can be grounded, ungrounded or exposed. The thermocouple junction may be of many different styles, from tube type to a washer configuration. The lead length may vary depending on the distance of the temperature controller from the thermocouple sensor. The metal that the sensor is constructed of determines the type of thermocouple manufactured.Applications: Plastic injection molding machinery Food processing equipment Engine and turbine exhaust gas Semiconductor processing Heat treating and metals processing Medical equipment Aerospace industries Packaging equipment Test stands Features Thermocouple Wires: Cromel-Alumel, Iron- Constant, Copper-Constant, imported Bright & Oxidized finish, SWG 10 to 36. PT/PTRH 10%, 13% . Thermocouple Extension & Compensating Cables: Fiber glass covered, PVC / PVC. Asbestos / Asbestosis, Teflon/Teflon, Insulated, Teflon/Fg/SS Braided single pair, multi pair, Type K, J, T, R, and PT-100 RTD Cables 2 core, 3 core, 4 core , 6 core, Also Teflon /silicon rubber Teflon/shielded/Teflon etc qualities. Thermocouple M.I. Cables: SS 316, 310 & Inconel 600 quality type K, J, Simplex 1mm,1.5mm, Simplex & Duplex 3mm,6mm, 8mm, also PT-100 RTD Thermocouple M I Cables SS 316 quality. 3mm, 5mm, 6mm 4 core Thermocouple Assemblies: Straight, L Type , Rotating type, Inmelt Bolt type, Pencil type, Washer, Holder with Spring. Rotating Type, Adjustable Types etc. Made out of SS tube 4.8mm, 6mm,supplied with Spring & Brass bayonets Single Slot & Double Slot , 10mm id, 12mm id, 14mm id, etc. Thermocouple Brass Parts: ADAPTORS 1/8 BSP, 1/4 BSP, 1/2 BSP, 3/8 BSP Single Pin, Double pin Bayonets. Carton box and wooden box.
Various types of thermocouple Can be widely supplied as Customer's requirment--good Erosion-resistant, corrosion-resistant 1) Thermocouples specified for food, health, medicine, and light industries 2) Inert-gas-filled thermocouples and thermocouples for temperature measurement on ships 3) Thermocouples with stainless steel terminal box Features: 1) Complete stainless steel structure 2) With npt threaded connection and flange 3) Assorts of lengths and diameters 4) Thermo-wells and assembled integrated transmitters are supplied. Plastic bags and carton box.
PH-099, designed for simultaneous pH and ORP measurements. It also reads temperature, which is continuously displayed on the dual level LCD. It is a waterproof pH, ORP and temperature meter. All pH readings are automatically temperature compensated(ATC). Measurements are highly accurate with a unique stability indicator right on the LCD. The pH electrode, supplied with the meter, is interchangeable and can be easily replaced by the user. Range : mV 0~1999mV pH : 0.00 to 14.00 pH Temperature : 0 to 55 Resolution : mV 1 mV pH : 0.01 pH Temperature : 0.1 Accuracy : mV 5mV pH : 0.1 pH Temperature : 1 Temperature Compensation : 0 to 50 Electrode : replaceable pH electrode (included);fixed ORP sensor Power Supply : 4 x 1.5V(AG13) Environment : 0 to 50 Dimensions : 170 x 40 x 23 mm Weight : 100 g.
Thermocouples are manufactured in many different configurations for multitude of applications. Diameters, lengths, sheath material, lead lengths and sensor material are just a few of the variables that go into determining the style of thermocouple when manufactured. The main determining factors of what type thermocouple needs to be used in a application is temperature, environment, response time and accuracy. The junction of the thermocouple can be grounded, ungrounded or exposed. The thermocouple junction may be of many different styles, from tube type to a washer configuration. The lead length may vary depending on the distance of the temperature controller from the thermocouple sensor. The metal that the sensor is constructed of determines the type of thermocouple manufactured. Applications: Plastic injection molding machinery Food processing equipment Engine and turbine exhaust gas Semiconductor processing Heat treating and metals processing Medical equipment Aerospace industries Packaging equipment Test stands Features: Thermocouple Wires: Cromel-Alumel, Iron- Constant, Copper-Constant, imported Bright & Oxidized finish, SWG 10 to 36. PT/PTRH 10%, 13% . Thermocouple Extension & Compensating Cables: Fiber glass covered, PVC / PVC. Asbestos / Asbestosis, Teflon/Teflon, Insulated, Teflon/Fg/SS Braided single pair, multi pair, Type K, J, T, R, and PT-100 RTD Cables 2 core, 3 core, 4 core , 6 core, Also Teflon /silicon rubber Teflon/shielded/Teflon etc qualities. Thermocouple M.I. Cables: SS 316, 310 & Inconel 600 quality type K, J, Simplex 1mm,1.5mm, Simplex & Duplex 3mm,6mm, 8mm, also PT-100 RTD Thermocouple M I Cables SS 316 quality. 3mm, 5mm, 6mm 4 core Thermocouple Assemblies: Straight, L Type , Rotating type, Inmelt Bolt type, Pencil type, Washer, Holder with Spring. Rotating Type, Adjustable Types etc. Made out of SS tube 4.8mm, 6mm,supplied with Spring & Brass bayonets Single Slot & Double Slot , 10mm id, 12mm id, 14mm id, etc. Thermocouple Brass Parts: ADAPTORS 1/8 BSP, 1/4 BSP, 1/2 BSP, 3/8 BSP Single Pin, Double pin Bayonets. Wooden box/carton.
1 RFT8100 wireless temperature and humidity detection system is composed by wireless temperature detection probes, humidity detection probes and display terminals. Adopting the advanced wireless temperature detection technology, RFT8100 transmits and displays the real time value detected from the local detection probes for the purpose of inspecting temperature and humidity on-site routinely. The alarm relay sends out signal when the temperature and humidity data exceeds or lowers the setting alarm value, and the alarm points can be found quickly by checking the alarm information. RFT8100 also provides curve diagram for checking temperature and humidity variation in short period for equipments management purpose. RFT8100 can achieve the remote monitoring function by transmitting the measured data to DCS monitor centre or equipments management centre thru RS-485 port or Ethernet port. 2 EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
1. Auto fan Adjust fan speed automatically according to the temperature Differential between set value and room temperature 2. Sleeping mode Adjust the setting temperature automatically according to the Thermal environmental conditions. 3. Shortcut menu Enter into the pre-setting temperature directly 4. Key-lock function To avoid erroneous operations 5. Timer off function To deactivate the thermostat at your pre-setting time 6. Timer on function To activate the thermostat at your pre-setting time 7. On/off key Zero power consumption after switching off 8. Back light(Optional) Display with backlight, stay on for 15seconds 9. LCD display Inclined larger size LCD display for better read out 10. Sensor calibration To ensure accurate temperature measurement 11. Setting min. /max. Allowed temperature 12. Valve indicator 13. Alternate from Cooling/heating by manual 14.18months Guarantee, ISO9001, CE, FCC.
1.Large LCD screen with blue backlight 2.Setting Temperature Range: 16-35º C,Room temperature:0-50º C 3.Wiring box: 86mm*86mm 4.High grade electronic accessory 5.TX-1008 remote controller is optional(Price is differ) 6.Temperature precision:1º C 7.Locked by remote controller is optional 8.Electric parameter: AC220V±10% 50/60Hz.
1.Temperature setpoint:16º C-35º C.room temperature: 0º C-50º C 2.LCD light screen shows the running condition of valve 3.Sleeping function 4.Manual alternate of cool or heat 5.Automatically adjust the wind speed 6.Set output delay time about 0-10 minutes 7.Advanced microcomputer control wafer 8.room temperature control precision 1º C. 9.Shell Material: White ABS flameproof plastic 10.Electric parameter: AC110/220V±10% 50/60Hz 11.Two-line, three-line motorized valve 12.Two-pipe, Four-pipe cooling and heating system.
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type RTD, TC, R or Millivolt signal Convert accuracy 0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output Max-load £¨V -13V£©/0.025A£¨Current output £© Limit current 25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: 3.6mA or ¡Ý21.0mA Power supply 13¡«30V DC Temperature drift 0.01£¥ FS/1 Long-term stability 0.1 per year or 0.05 £¥per year Ambient -40¡«+85.
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use the MS181 programming tool Measuring range Set via PC PC Interface USB/RS232 Input type RTD, TC, R or Millivolt signal Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output Max-load £¨V -8V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or¡Ý21.0mA Power supply 8¡«30V DC Temperature drift 0.01£¥ FS / 1 Long-term stability ¡Ü0.1 per year or 0.05£¥ per year Ambient -40¡«+85
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type Dual-input ( RTD, TC, R or Millivolt signal) Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1¡æ(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output (2-way) Max-load £¨V -16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500VAC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or ¡Ý21.0mA Automatic switching while sensor damaged Power supply 16¡«30V DC Temperature drift 0.01£¥ FS/1¡æ Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
• Universal PC programmable (PCP) • 2 wire technology, 4 to 20 mA analogue output • High accuracy in total ambient temperature range • Configuration during measurement using configuration kit • Customer specific measurement range setting • Wide measurement range, according to requirement Field of application • PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal • Input: Resistance thermometer (RTD) Pt100 • Configuration using a PC with MS180 configuration kit (MS180-PC). Appearance and Size (in mm) NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
MS150 Series multi-channel temperature monitor is a multi-point temperature measurement instrument. It takes the highest measured temperature in measuring loops as its output signal which is sent out in the form of a 4 to 20 mA standard current signal and the temperature is displayed by the built-in LED. If required, temperature at any measuring point can be shown by operating the keys on panel. Isolation is provided between the input and output. It is mainly used in the applications of multi-point temperature measurement or alarm warning system. By adopting SMT technology, it offers excellent accuracy, reliability and anti-disturbance. Primary Technical Characteristics Measuring range 0¡«100¡æ¡¢0¡«150¡æ¡¢0¡«200¡æ £¨according to user's demand£© Input type Pt100,Cu50£¨TC if specially required£© Measuring Points 2,3,4,5,6 points Convert accuracy ¡Ü0.5£¥FS linearity error < 0.1% Output 4¡«20mA Electrical isolation output Digital display LED Display accuracy 0.5% Voltage drop for display 3V Isolated voltage Drop 2V Isolate Voltage 1500V AC (Input/Output¡¢with isolator) Max-load £¨V -14V~16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Power supply 14~30V DC Temperature draft 0.025% FS/ 1¡æ Long-term stability ¡Ü0.1¡æper year or 0.05£¥ per year Ambient -40~+85¡æ£¨Aluminium alloy .Casing£© -25 ~+75¡æ£¨Plastic Casing£© Protection level IP66£¨Aluminium alloy£©/IP62£¨Plastic£© Anti-RFI >10v/m(80MHz¡¡1000MHz).
SSR, 0-10v- P, PI, PD, PID Or ON/OFF Hysteresis Control, Selectable Sensor Input (J type (Fe-Const), K type (NiCr-Ni), Pt100, R type (PtRh13Pt), S type (PtRh10Pt), T type (Cu-Const) ).
Cooling and heating controller.
Fan controllers Light control / baybus Front i/o adapters Temperature sensors Configurable lcd displays Fan speed controller Manual rpm control Multi fan controller, Fan rpm monitoring and control . Cartons.
The controller is designed for aquarium controlling.It process is directly and efficiently perceived through the senses.The autocontrol including temperature, pump an lights.The customer setting can be remembered when the power shut down.For the physical desigh, we seperate the high voltage circuit from the controlling circuit.This is safe for the operating personnel.The power board print every output name , such as light, uv, .Etc.The controller is necessary for aquarium. CARTONS
Main function: cooling, heating, ventilation, fresh air, error alarm, 3-grade air-flow adjustment, hold cooling. Application: KINGTECH,LIUGONG Machinery, XGMA Machinery.