Shoulder bag & backpack 2 way, convenient to use anywhere
This Korean made Closed Expansion Tank acts as a substitute of open expansion tank to prevent the corrosion of pipes. It guarantees smooth operation by completely intercepting the contact of pipe water in cooling, heating and hot water heating pipes with an air and filling proper pressure to receive and restore expansion water. This Korean made Expansion Tank is available in variety of sizes and capacities to fit your application. [ FEATURES ] PREVENT PIPE CORROSION Ass contact with air is intercepted completely, air cannot get mixed with water so the span of pipes is prolonged as corrosion is prevented. WATER SUPPLY UNNECCESSARY No make-up water is needed as no pipe water is lost by evaporation or overflow. COMPLETE AIR DISCHARGE FUNCTION The air venting system of pipe is good its pressure is properly maintained. LIMITELESS INSTALLAION APPLICATION As it can be installed in every place including basements, roof tops and mid-stories, it is not frozen to burst and space can be utilized. EXTENDED OPERATIONAL TEMPERATURE RANGE Pressure needed for pipe system can be easily maintain, so operational temperature over 100â?? from medium or high temperature water system can be easily obtained. GUARANTEED SMOOTH OPERATING PERFORMANCE Effective operation is possible without problems of pipe circulation, pump efficiency, pipe noise and vibration caused by air mixture. SANITARY SYSTEM OPERATION Hot air heating system is sanitary because hot air is not opened to the air. NO MAINTENANCE IS REQUIRED No maintenance is needed and the lifespan of tank and membrane is semi-permanent, no heat loss exists and energy is saved. The lifespan of piping in life cycle cost. [ SPECIFICATIONS ] * Shell : Fabricated steel designed and constructed as per ASME Section VIII, Div. 1 * Bladder : Butyl Rubber * Design Pressure : 125 psiG (862 kPa) Options : 150 psiG (1034 kPa), 175 psiG (1206 kPa), 250 psiG (1723 kPa), 300 psiG (2068 kPa) * Design Temperature : 240 (116 ) * Tank Volume : 40~5000 litters
FINETANK, the fine tank from Korea, the high quality WATER STORAGE TANKS made of SMC PANELS & STEEL REINFORCEMENTS are available in various capacities and different shapes for various applications (residential/commercial buildings, water treatment plant, fire fighting, irrigation, etc.). FINETANK - GRP SECTIONAL WATER TANK complies to KSF 4811, KSM 3305, KSM-3401 (Korean Standard), BS 6920:2000 (British Standard), SS245:1995 (Singapore Standard) FINETANK, the WRAS approved GRP SECTIONAL WATER TANK is being produced by the ISO-9001 certified Korean manufacturer. [ ADVANTAGES ] EXCELLENT HYGIENIC PROPERTISE * Nontoxic, WRAS certified materials * Suppression of algae and microorganisms with excellent blocking of sunlight * Minimization of moss and scale by smooth surface finish OUTSTANDING DURABILITY * Optimal system by FEM (Finite Element Method) design. * Anti-corrosion materials in SS316, HDG and PE coated S.S. ABSOLUTE WATER TIGHTNESS * Foam type gasket with excellent elasticity and resilience. FREE CAPACITY DESIGN * Various shapes to meet different site conditions (Square / Center vacant square / L-shape / Channel-shape, etc) * Versatile capacities (0.5m3 ~ 5,000m3). * Various panel sizes : 1x1, 0.5x0.5, 1x0.5, 0.3x0.3, 1x2, 1.15, etc. EASY INSTALLATION & MAINTENANCE * User-friendly installation even in the restricted area by using standardized panels and reinforcements. PRE-INSULATED PANELS (optional) * PU foam pre-insulated panels to avoid high heat or cold. MUTI-COMPARTMENTS (optional) * A tank can be partitioned into multi-compartments for respective use when tank is under cleaning or maintenance. [ SPECIFICATIONS ] 1 Panel : Hot-press molded SMC panel 2 Insulation : Poly Urethane Foam 3 Inner tie-rod : Stainless steel 316 / 304 / Stainless steel with PE coating - optional (External reinforcement system ->No inner tie-rod system is available up tp 4mH) 4 Roof support : SMC pultrusion pipe 5 External reinforcement : Hot dip galvanized steel 6 Roof support : SMC pultrusion pipe 7 Inner bolts : Stainless steel 316 / 304 8 External bolts : HDG steel / Stainless steel / Rubber capped steel 10 External ladder : HDG steel There're more options you're looking for. For more details, please feel free to contact us !
FINETANK - GRP SECTIONAL WATER TANK - High quality WATER STORAGE TANKS made of GRP PANELS & STEEL REINFORCEMENTS are available in various capacities and different shapes for various applications (residential/commercial buildings, water treatment plant, fire fighting, irrigation, etc.) FINETANK, the fine tank from the ISO-9001 certified Korean manufcaturer complies to international standards WRAS, BS, KS, SS. [ ADVANTAGES ] EXCELLENT HYGIENIC PROPERTISE * Nontoxic, WRAS certified materials * Suppression of algae and microorganisms with excellent blocking of sunlight * Minimization of moss and scale by smooth surface finish OUTSTANDING DURABILITY * Optimal system by FEM (Finite Element Method) design. * Anti-corrosion materials in SS316, HDG and PE coated S.S. ABSOLUTE WATER TIGHTNESS * Foam type gasket with excellent elasticity and resilience. FREE CAPACITY DESIGN * Various shapes to meet different site conditions (Square / Center vacant square / L-shape / Channel-shape, etc) * Versatile capacities (0.5m3 ~ 5,000m3). * Various panel sizes : 1x1, 0.5x0.5, 1x0.5, 0.3x0.3, 1x2, 1.15, etc. EASY INSTALLATION & MAINTENANCE * User-friendly installation even in the restricted area by using standardized panels and reinforcements. PRE-INSULATED PANELS (optional) * PU foam pre-insulated panels to avoid high heat or cold. MULTI-COMPARTMENTS (optional) * A tank can be partitioned into multi-compartments for respective use when tank is under cleaning or maintenance. [ SPECIFICATIONS ] 1 Panel : Hot-press molded SMC panel 2 Insulation : Poly Urethane Foam 3 Inner tie-rod : Stainless steel 316 / 304 / Stainless steel with PE coating - optional (External reinforcement system ->No inner tie-rod system is available up tp 4mH) 4 Roof support : SMC pultrusion pipe 5 External reinforcement : Hot dip galvanized steel 6 Roof support : SMC pultrusion pipe 7 Inner bolts : Stainless steel 316 / 304 8 External bolts : HDG steel / Stainless steel / Rubber capped steel 10 External ladder : HDG steel * INternational Certificats : WRAS, PSB, ISO-9001 There're more options you're looking for. For more details, please feel free to contact us !
Material : - 304 Stainless Steel - Magnetic Induction bottom Origin : Korea Thickness - Body - 2.3T - Cover - 1.0T Size : - Saucepan :16cm - Pot - 18cm, 20cm - Steam Pot (with steamer) : 24cm - Casserole - 24cm
Ready mixed wall tile adhesive for common format tile less than 250 x 400mm, 2.2kg Ready to use - no mixing required Non-flammable Good water resistance and persistence Quick and easy installation Excellent grab on vertical surfaces 12, 14, 17, 20kg in a plastic container
Refrigerant : R22 * 60Hz : 3,440~8,770 Btu/h * 50Hz : 4,200~7,100 Btu/h. Application * Small Room Air Conditioner * Dehumudifier * Water Cooler. Power Source * 1PH, 115V - 60Hz * 1PH, 208-230V - 60Hz * 1PH, 200-220V - 50Hz * 1PH, 220-240V - 50Hz.
Refrigerant : R22 * 60Hz : 22,100~41,000 Btu/h * 50Hz : 24,000~33,750 Btu/h. Application * Room Air Conditioner * Package Air Conditioner * Unitary System * Cold Storage. Power Source * 1PH, 208-230V - 60Hz * 3PH, 380-420V - 60Hz * 1PH, 220-240V - 50Hz * 3PH, 380-420V - 50Hz.
Refrigerant : R22 * 60Hz : 13,900~24,650 Btu/h * 50Hz : 11,800~18,700 Btu/h. Application * Room Air Conditioner * Package Air Conditioner. Power Source * 1PH, 115V - 60Hz * 1PH, 208-230V - 60Hz * 1PH, 265V - 60Hz * 1PH, 200-220V - 50Hz * 1PH, 220-240V - 50Hz * 1PH, 220V - 50Hz.
0.62/m2(flat). 1.60/mt(conner) . (500, 300, 200)mm x 100mm x 43mm.
1. Patent item 2. Symple installation 3. Enviromenatal product Standard packing
Innovative urinal/toilet bowl sterilizer Removes numerous harmful bacteria, allergic materials, various chemicals and pollutants inside urial and eliminates bad smell from urinal/toilet bowl, keep public toilet fresh and stink-free Size : 70 x 132 x 63mm Weight : 200g
The soft bathtub is a cushioned bathtub made of a new soft materials to be pressed gently by hand. When lying down in bathtub, bathers will feel more comfortable than in a regular and accidents are also better prevented.
The soft bathtub is a cushioned bathtub made of a new soft materials to be pressed gently by hand. When lying down in bathtub, bathers will feel more comfortable than in a regular and accidents are also better prevented.
1) Cute package 2) various certificates Derma test, KOTITI, ISO22716, ISO09001, KC 3) Wet tissue for baby 4) Size 180*140mm, 203g
SYSTEM INFORMATION The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
System Information The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
Low maintenance cost and easy installation Long lasting performance: No maintenance and repair for 6 years â?¢ Intelligent information can be output by providing advanced statistical data and diagnostic programs â?¢ Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small area (Q1 â?¤ Q â?¤ Q2) [ SPECIFICATIONS ] * Measuring caliber 25 mm ~ 1,200 mm * Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm * Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator * Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade) * Max. Measureable Flow Rate : 10 m/s * Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger * Measurement function : Low flow cut off: 0 ~ 9 of maximum flow * Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz * Max working pressure : 1.0 MPa ~ 1.6 MPa * Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type * Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type 2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA (Common for AC & Battery Type) * Liner : Hard Rubber * Electrode Hastelloy C * Housing/Flange : Carbon Steel * Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage) * Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC * Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%) * Protection class : Detection unit (IP 68) / Converter (IP 65) [ APPLICATIONS ] Water industry / Wastewater treatment industry For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
[ CHARACTERISTICS ] Wide Beam Transducer (Broadband ultrasonic measurement function) Determine the transmission frequency by finding the resonance frequency of the pipe according to the outer diameter, material, and thickness of the pipe â?¢ Little error occurs due to stable signal reception â?¢ Excellent measurement stability even when there are air bubbles slurry (30% or less), scale generation, changing temperature and density. How to install â?¶Pipe Configuration (automatic correction of disturbance factors) â?¢ In actual industrial sites, sufficient straight pipe without interference is required for accurate flow measurement â?¢ If no sufficient straight pipe is secured ; - Re estimation of correction factors for disturbance factors and distances from disturbance factors, self compensation. - It has the same accuracy as that in which a sufficient intuition is secured even at a short distance from the disturbance factor. â?¶Other Functions * Diagnostic Menu (Self diagnosis function) * Auto Zero (Automatic zero adjustment function) * MultiPulse Transmission (Multi pulse function) * Liquid Class Menu (Fluid selection function) [ SPECIFICATIONS ] * Ultrasonic firing method : Wide beam * Flow measurement range : 0.0003 m/s ~ 30 m/s (by diameter) * Accuracy : HUF 2000N: within 0.5 ~ 1% (Normal / Precision sensor) HUF 2000DN: Within 0.5% (Precision sensor) * Measurable pipe diameter : 6.4 mm ~ 6,000 mm * Measurable pipe material : Steel, ABS, Aluminum, Black Iron, Brass, Cast Iron, Copper, Ductile, Glass, Hastelloy, etc. * Measurable fluid : Water, Wastewater, Oil (Turbidity 30,000 mg / L or less, Bubble 30% or less) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : General sensor (40 ~ 120 â??), High temperature sensor (40 ~ 230â??), Indicator (18 ~ 60â??) * Display : HUF 2000N: 100 x 55 / HUF 2000DN: 120 x 64 * Display contents: Instantaneous flow rate (4 digit), Accumulated flow rate (8 digit), Flow rate (3 digit), Pressure (4 digit), Ultrasonic velocity (Vs ), Air volume (Air), Signal strength, * Flow / Time display unit : m3 & L / Forward & Reverse (--) / Second (s), Minute (min), Hour (h) & Day * Input signal : HUF 2000N: 1 pressure signal / HUF 2000DN: 2 4 ~20 mA, 2 RTDs * Output signal : 4~20 mA, Integrated pulse, RS232 / RS 485 MODBUS * Protection grade : Sensor: IP 68 / Indicator: IP 65 * Sensor cable length : Max. 600m * Storage content and capacity : Date, time, instantaneous flow rate, integrated flow rate, pressure, signal intensity, ultrasonic velocity, etc. Memory storage at regular intervals (5 sec. ~ 24 hrs.) (1 year can be stored at 1 min. intervals)
[ CHARACTERISTICS ] Low maintenance cost and easy installation Long lasting performance: No maintenance and repair for 6 years Intelligent information can be output by providing advanced statistical data and diagnostic programs Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small area (Q1 â?¤ Q â?¤ Q2) [ SPECIFICATIONS ] * Measuring caliber 25 mm ~ 1,200 mm * Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm * Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator * Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade) * Max. Measureable Flow Rate : 10 m/s * Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger * Measurement function : Low flow cut off: 0 ~ 9 of maximum flow * Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz * Max working pressure : 1.0 MPa ~ 1.6 MPa * Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type * Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type 2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA (Common for AC & Battery Type) * Liner : Hard Rubber * Electrode Hastelloy C * Housing/Flange : Carbon Steel * Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage) * Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC * Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%) * Protection class : Detection unit (IP 68) / Converter (IP 65) [ APPLICATIONS ] Water industry / Wastewater treatment industry