Low maintenance cost and easy installation
Long lasting performance: No maintenance and repair for 6 years
â?¢ Intelligent information can be output by providing advanced statistical data and
diagnostic programs
â?¢ Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small
area (Q1 â?¤ Q â?¤ Q2)
[ SPECIFICATIONS ]
* Measuring caliber 25 mm ~ 1,200 mm
* Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm
* Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator
* Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade)
* Max. Measureable Flow Rate : 10 m/s
* Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger
* Measurement function : Low flow cut off: 0 ~ 9 of maximum flow
* Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz
* Max working pressure : 1.0 MPa ~ 1.6 MPa
* Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type
* Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type
2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA
(Common for AC & Battery Type)
* Liner : Hard Rubber
* Electrode Hastelloy C
* Housing/Flange : Carbon Steel
* Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage)
* Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC
* Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%)
* Protection class : Detection unit (IP 68) / Converter (IP 65)
[ APPLICATIONS ]
Water industry / Wastewater treatment industry
For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
[ CHARACTERISTICS ] Low maintenance cost and easy installation Long lasting performance: No maintenance and repair for 6 years Intelligent information can be output by providing advanced statistical data and diagnostic programs Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small area (Q1 â?¤ Q â?¤ Q2) [ SPECIFICATIONS ] * Measuring caliber 25 mm ~ 1,200 mm * Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm * Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator * Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade) * Max. Measureable Flow Rate : 10 m/s * Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger * Measurement function : Low flow cut off: 0 ~ 9 of maximum flow * Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz * Max working pressure : 1.0 MPa ~ 1.6 MPa * Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type * Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type 2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA (Common for AC & Battery Type) * Liner : Hard Rubber * Electrode Hastelloy C * Housing/Flange : Carbon Steel * Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage) * Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC * Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%) * Protection class : Detection unit (IP 68) / Converter (IP 65) [ APPLICATIONS ] Water industry / Wastewater treatment industry
--- It is suitable forpipe sizes ranging from 40 to 4000mm --- For dirty liquids, a certain amount of air bubbles or suspended solids shall be contained --- Excellent low flow rate measurement ability, low to 0.05m/s. --- A wide range of flow measurement, high flow rate can reach 12m/s --- High-temperature transducer is suitable to liquids of -35â?? ~ 200â?? --- Do not need to shut down the pipe flow when installing the transducers --- User-friendly configuration --- 4-20mA, Relay and OCT outputs --- Accuracy: 2.0% Calibrated span
Supplier: Ultrasonic flow meters, electromagnetic, ultrasonic water meters
Buyer: Used lathe machine
1. Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt. 2. Wide liquid temperature range: -35~200. 3. Data logger function. 4. 14 hours battery(rechargeable), back-lit 4 lines display. 5. For commonly used pipe materials and diameters from 20mm to over 6.0m. 6. Wide bi-directional flow range of 0.01 m/s to 12 m/s.
Process connection as per ASME / EN / AWWA / JIS 3 line LCD backlit display SS construction Bidirectional flow Multiple communication protocols Built-in diagnostics"
Electromagnetic flow meter
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages:
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages:
water meter