Pressure-Volume and Flow-Volume, displayed waveforms can be cycled instantly with a touch of a button 3.Standard integrated metallic modular respiratory circuit; completely solves the problem of gas sealing under high temperature disinfection, easy to clean and disinfect 4.Power Failure Support Functions: Automatically converts to backup power mode during AC power outages 5.Equipped with electronic pressure differential flow sensor, imported respiratory control valve, stable and reliable, rapid response time 6.High precision five tube flowmeter, fitted with interlocking oxygen-nitrous oxide supply, guarantees oxygen output is never lower than 21% 7.Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an automatic self-calibrating sensor 8.Alarms: Audible and/or visual alarms for tidal volume, airway pressure, oxygen concentration, asphyxia, power failure, oxygen failure and other alarms, also features a alarm query function 9.Vaporizer: Imported tank components assembled locally; Enflurane, Isoflurane and Sevoflurane (Halothane optional). Also possesses self-compensating functionality 10.Advanced and stable Adjustable Pressure Limiting (APL) valve, suitable for low and ultra low flow anesthesia 11.Equipped with advanced international rotating Na-lime tank, easy-operate, requires only one hand, and uses imported PPSU material and temperature resistant to 134�°C 12. Multi-parameter Patient Monitor: Optional
Drager Medical OxyLog Pneumatic Ventilator
Medical Ventilator (Model SH300/PA900B/SH200A/) Ventilation specification Tidal volume l:E Monitoring specification VTI, VTE , MV, MVspn Fspn, Frequency, l:E Ppeak, Pmean ,Pplat, Pmin, PEEP Ã¥·³02 Compliance, Resistance P-T, F-T, V-T, P-V loop, V-F loop 20-2500ml Ventilation mode : VCV, VCV +Sigh, PCV, PRVC, SIMV+VCV, SIMV+PCV, SIMV+PRVC ,SPONT (CPAP/PSV) , BIPAP, APRV NIV/CPAP, NIV/PCV 1:10-10:1 lnspiratorytime: 0.1-12 s Pause time Pressure trigger sensitivity Flow trigger sitivity PEEP/CPAP Psupp Pinsp Phigh Plow 02 suction Ins.Hold Exp.Hold Manual ventilation Waveform Freeze: Yes Nebulization C02(optional) ETC02(optional) Optional Air compressor Humifier Support arm 0-50% (PEEP-20 to OcmH20) 1 - 20LPM 0- 50cmH20 0- 70cmH20 5- 70cmH20 21-100% 0- 70cmH20 1 00% 02 ventilation for 2mins 15s Max 15s Max 0-60 minutes adjustable CE
Model:PA - 700b - Specifications on request PRICE: $60500 FOB QTY available: 100 Lead time: Ready to go now in stock. Potentially 200-500 available in two weeks. Payment Terms: 50% deposit payment upon video Proof of Product by manufacturer via real time dated factory video of ready stock, SGS verification and production of manufacturer's certificate. Balance 50% against shipping documents.
We have various icu and portable ventilator model . Example: VG 70 , S1100 , S3010ï¼? V6ï¼? 510Sï¼? YH-830ï¼? SH300 and ACM812A .
Package size 1 test/kit, 10 tests/kit, 20 tests/kit, 50tests/kit and 100 tests/kit. Intended use This product is used to qualitative detection of the presence of IgG antibody to SARS-CoV-2 in Human serum, plasma and/or whole blood. The common symptoms are fever, cough, polypnea and anhelation when infected with SARS-CoV-2. In more serious cases, infection may cause pneumonia, severe acute respiratory syndrome, renal failure and even death. Coronavirus can be excreted through respiratory secretions and transmitted by air droplet. Infection may be caused by saliva, sneeze and contact. Principle A Monoclonal Mouse Anti-Human IgG conjugated to colloidal gold and embedded in the sample pad reacts with the IgG antibody to SARS CoV-2 present in whole blood, serum or plasma forming conjugate/ SARS-CoV-2 antibody complex. As the mixture is allowed to migrate along the test strip, the conjugate/ SARS-CoV-2 antibody complex is captured by recombinant SARS-CoV-2 antigen immobilized on a membrane forming a colored test line in the test region.
Format: Cassette Storage: 4-30�ºC Certificates: ISO13485 Specimen: Whole Bood,Serum / Plasma Read time: 10-15 Minutes Weight: 101g Sample rule Option 1: Offering existing samples Option 2: Customized samples based on customers' specifications Sample lead time 3-10days (depends on the style) Result: 15 Minutes Shipping mode 1.Sea shipment 2.Air shipment 3.Door to door parcel Intend to use 1.The New Coronavirus (Sars-CoV-2)Test is a rapid chromatographic immunoassay for the qualitative detection of Antibody(IgG) to coronavirus in human whole blood, serum or plasma specimens. 2.Common signs of coronavirus infection include respiratory symptoms, fever, cough, wheezing and dyspnea. In more severe cases, the infection can lead to pneumonia, severe acute respiratory syndrome, kidney failure and even death. Corona viruses can be excreted through respiratory secretions, transmitted through oral fluids, sneezing, contact, and through the air droplets spread. Positive:1. Two or three distinct lines appear. One line should always appear in the control line region (C), and another one or two apparent colored line(s) should appear in the test line region(s) (T1 and T2). 2. If a line appears on the quality control line, a line appears on the test line T1, and no sline appears on the test line T2, it indicates that IgG antibody is present in the sample and no IgM antibody is present. 3. If a line appears on the quality control line, a line appears on the test line T2, and no sline appears on the test line T1, it indicates that IgM antibody is present in the sample and no IgG antibody is present. Negative: One colored line appears in the control region (C). No Apparent colored lines appear in the test lines regions (T1 and T2). Invalid: Control line(C) fails to appear. Insufficient specimen volume or incorrect procedural technologies are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor. Note: The red line in the test line (T) can show different shades of color. However, even a very weak line should be judged as a positive result during the specified observation period, regardless of the color of the line.
Please receive quotation for China made brand new Ventilators: Shangrila 510S. Price: - 48650$ per device FOB Delivery time: 2 weeks time MOQ: 100 Devices AEONMED VG70. Price - 70600$ per device FOB Delivery time: 3 weeks time MOQ: 100 Crius V6. Price� - 41000$ per device FOB Delivery time: 2 weeks time MOQ: 50 Please contact for detailed specifications. Payment: Deposit 50% by TT in advance. Balance 50% upon delivery. Not negotiable. Shipment: By air.
Please receive quotation for China made brand new Ventilators: Shangrila 510S. Price: - 48650$ per device FOB Delivery time: 2 weeks time MOQ: 100 Devices AEONMED VG70. Price - 70600$ per device FOB Delivery time: 3 weeks time MOQ: 100 Crius V6. Price� - 41000$ per device FOB Delivery time: 2 weeks time MOQ: 50 Please contact for detailed specifications. Payment: Deposit 50% by TT in advance. Balance 50% upon delivery. Not negotiable. Shipment: By air.
Rapid Result COVID -19 (SARS CoV-2 ) Tests (whole blood/serum/plasma) COVID-19 IgG/IgM Rapid Test Cassette Made in the USA Results Show in 10 Min. or Less Simple, Time-Saving Procedure Highly Sensitive and Specific 25 Tests per Box MOQ - 16,000 Tests is 1 Pallet This IgG/IgM antibody detection test is a rapid visual immunochromatographic sandwich assay for the qualitative detection of IgG and IgM antibodies from human whole blood or serum. Rapid Test Cassettes are intended for point of care application, not for home use. Results from this test should not be used as the sole basis to diagnose or exclude SARS- CoV-2 infection or to inform infection status. Positive results may be due to past or present infection with non-SARS-CoV-2 coronavirus strains (coHKU1, NL63, 0C43, or 229E). Consider follow up testing with molecular diagnostic to rule out infection in these individuals. Negative results do not rule out SARS-CoV-2 infection, particularly in those who have been in contact with the virus. Results from one antibody testing should not be used as the sole basis to diagnose or exclude SARS-CoV-2 infection or to inform infection status. MADE in the USA
Suitable for proximal knee fracture, patella fracture, dislocation, meniscus injury, back bending and ligament injury or repair fixation. This product adopts socket connection, which is very convenient for installation and disassembly. ABS engineering plastics is used to adjust the dials, which can be adjusted from 0 to 120 degrees arbitrarily.
Manufacturer: Shenzhen Prunus Medical Co., Ltd Boaray 5000D is a high performance ventilator for ICU. Powerful and optimal ventilation modes The DualPAP ventilation mode is able to provide the patient with biphasic horizontal pressure (high pressure phase and low pressure phase). With the suitable pressure, this perfect modes not only exercises the patient's breathing muscles, but also reduces the reliance on the ventilator. Freeflow is an advanced closed-loop control technology with square wave pattern and decelerating flow pattern. Under the square wave pattern, the patient is able to breathe spontaneously in the inspiratory phase, while under the decelerating flow pattern, the system is able to adjust the flow rate according to the patient's compliance and resistance changes. It means this advanced mode greatly reducing the use of sedatives and muscle relaxants, and has obvious effects on patients with atelectasis, ARDS, acute pulmonary edema, and asthma. Comprehensive and visible monitoring function With 15 inch color touch screen, the Boaray 5000D is able to show 4 waveforms and 2 loops simultaneously. And it can monitor more than 20 important parameters to help you know the patient status in anytime. Free breathing technology for breathing freely The free breathing technology can release excessive pressure caused by a cough or active exhalation, to ensure patient safety and make breathing more comfortable. Featuresï¼? �· Vt range: 20-2000ml; Applicable to adult, pediatric and infant �· Ventilation modes: VCV, PCV, SIMV(P)+PS, SIMV(V)+PS, SPONT/CPAP, Sigh, PRVC, DualPAP, NPPV, Manual, Standby �· Weaning parameter ( RSB, P0.1, NIF) �· 15 inch TFT touch screen & big front view for easy observation �· Simultaneous display of 4 waveforms and 2 loops �· CO2 and SpO2 monitoring (optional) �· Synchronized nebulizer and air compressor (optional) �· Expiratory valve could be taken off for autoclavable disinfection to avoid cross-infection �· Active exhalation valve with anti-condensation design �· World leading brands of key components of ventilator ensure high accuracy and stable performance �· Advanced proportional solenoid technology realize accurate ventilation control �· Multi-safety mechanism and three-priority alarm of visual and audio for different risks
Test for coronavirus in 15 minutes results coronavirus testing agent Coronavirus Test COVID-19 IgM Ab Rapid Test Home Use Antibody COVID-19 Igg/IgM Ab Rapid T
COVID-19 Emergency Ventilator Machine
Product Paramenters Dimensions: 170mm x 180mm x 118mm 290mm x 180mm x 134mm Weight : 1.5kg 2.5kg (with the humidifier) Water Capacity: 350ml at recommendadwater level Ramp the ramp time ranges from 0 to 60 mintes Humidifier Setting off, 1 to 5 (90 �°F to 167 �°F/35 �°C to 75 �°C ï¼? Output No less than 10 mg H20/L Sp02 Range: 0 to 100% Pulse Rate 40 to 240 BPM AC power Consumption 100 -240 VAC, 50/60 Hz Max 2 A
Product Paramenters Dimensions: 170mm x 180mm x 118mm 290mm x 180mm x 134mm Weight : 1.5kg 2.5kg (with the humidifier) Water Capacity: 350ml at recommendadwater level Ramp the ramp time ranges from 0 to 60 mintes Humidifier Setting off, 1 to 5 (90 �°F to 167 �°F/35 �°C to 75 �°C ï¼? Output No less than 10 mg H20/L Sp02 Range: 0 to 100% Pulse Rate 40 to 240 BPM AC power Consumption 100 -240 VAC, 50/60 Hz Max 2 A
ACM812A invasive ventilators 50-100 sets available. Payment by irrevocable confirmed back to back LC at sight.
Infant , neonatal use 12.1 Touch TFT color screen Display 3 waveforms and 2 loop curves simultaneously Modes ; VCV / PCV / PSV / CPAP / SIMV (PCV) + PSV / SIMV (VCV) + PSV / APRV / PRVC / TCPL / SIMV (TCPL) + PSV / CPAP + Continuous streaming Calculations ; AutoPEEP / Compliance / Resistance / P0.1 / PV Flex / Pimax / WOBi / RSBI Apnea backup ventilation Internal battery 150 minutes 72 hours memory for all parameters Built in nebulization output Low cost maintenance Automatic calibration at start up Event recording with 2000 occurrence times Automatic adjustment according to patient weight at opening Pressure and flow trigger detection feature Leakage volume compensation feature Tidal volume adjustment in the range of 2ml 350ml Automatic 100% FiO2 delivery before and after aspiration
Reusable long life built in flow sensor Selectetec with dual vaporizer can be installed Built in 6 airway monitor Flowmeter four tubes (O2, Air , N2O) Rebreathing system (Co2 absorber ) Silicone / reusable patient circuit Patient circuit holder Arm Low Flow , Minimal Flow with all accessories Horizontal Ventilation with Bag in bottle System Volume control , Pressure Control, SIMV, VS, Spontaneous and manual ventilation Modes Tidal volume compensation , Resistance compensation , Compliance compensation Automatic leakage compensation Anti Baro, Anti Volume trauma feature Infant with the same system , pediatric , adult use Advanced alarm system 10 1600 ml Tidal Volume Adjustment APL Safety Valve and FiO2 monitoring Electronic PEEP 0 20 mbar 4 hours internal battery Optional vaporizer Turkish user menu
Vetlabs Babesia gibsoni test kit is developed and manufactured by Bioguard Corporation. B. gibsoni test kit is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Babesia gibsoni Ab in dog's blood specimen. Specimen: Serum, Plasma, Blood Animal: Canine Measurement time: 5~10 minutes Package: 5 test kits per box