Product Paramenters
Dimensions:
170mm x 180mm x 118mm
290mm x 180mm x 134mm
Weight :
1.5kg
2.5kg (with the humidifier)
Water Capacity:
350ml at recommendadwater level
Ramp
the ramp time ranges from 0 to 60 mintes
Humidifier
Setting off, 1 to 5 (90 �°F to 167 �°F/35 �°C to 75 �°C ï¼?
Output No less than 10 mg H20/L
Sp02
Range: 0 to 100%
Pulse Rate
40 to 240 BPM
AC power Consumption
100 -240 VAC, 50/60 Hz Max 2 A
Product Paramenters Dimensions: 170mm x 180mm x 118mm 290mm x 180mm x 134mm Weight : 1.5kg 2.5kg (with the humidifier) Water Capacity: 350ml at recommendadwater level Ramp the ramp time ranges from 0 to 60 mintes Humidifier Setting off, 1 to 5 (90 �°F to 167 �°F/35 �°C to 75 �°C ï¼? Output No less than 10 mg H20/L Sp02 Range: 0 to 100% Pulse Rate 40 to 240 BPM AC power Consumption 100 -240 VAC, 50/60 Hz Max 2 A
4000$ per one unit. A BPAP machine is a type of ventilatorâ??a medical device that assists with breathing. These machines extend the benefit of a CPAP machine by adding large breaths on top of stable airway pressure and will help in pushing air into lungs from a mask or nasal cannula connected to the machine. Complex Treatment Solution for patients with respiratory insufficiency which can effectively improve blood oxygenation and reduce mortality of patients with 2019-nCoV, is one of the main ways to treat 2019-nCoV.
An endobronchial tube is a medical device designed for use in the respiratory system, specifically within the bronchial tubes. These tubes are used in various medical procedures, such as bronchoscopy, endobronchial intubation, and lung surgery. The primary purpose of an endobronchial tube is to maintain an open airway and facilitate the delivery of oxygen or anesthesia to the patient's lungs during surgical or diagnostic procedures. Key features and uses of endobronchial tubes include: Bronchoscopy: Endobronchial tubes are often used in bronchoscopy procedures, allowing physicians to visually examine the bronchial tree and perform diagnostic or therapeutic interventions. Lung Surgery: During certain lung surgeries, endobronchial tubes may be employed to isolate and collapse one lung, providing a clear field of view for the surgeon. Ventilation: Endobronchial tubes can be used for selective lung ventilation. They can be positioned to direct ventilation to a specific lung, allowing the other lung to be collapsed or isolated. Anesthesia: In some cases, endobronchial tubes are used for delivering anesthesia during thoracic surgeries or procedures.
Breathing Bags Product Code: MED 119 Specifications: Sterile, individually packed in a polybag Size/Strength: 0.5ltrs, 1.0ltrs, 2.0ltrs, 3.0ltrs Description comfortable in usage, these feature thin, durable designs and can be made available in different finish sizes to pick from to fit patientâ??s specific needs. hourglass-shaped breathing bag also helps in reducing the fatigue of the hands as well as also provide firm grip to the hands. The tri-pleat design also offers a better fit over patient's face. Breathing Bags are the devices finding application that temporarily assist patients to breathe. These Anaesthesia Bags bags are used with face mask that is placed over patient's mouth and nose and is connected to oxygen source for providing complete breathing ease. These bags are squeezed and this leads to oxygen being pushed into patient's lungs
Basic ventilator circuits Product Code: MED 121 Specifications: Sterile, individually packed in a polybag Size/Strength: Adult, Pediatric Description Wide range, high transparency, Flexibility Minimum compliances and sterile. Ventilator Circuit is the gas pathway connecting patients lung to the mechanical ventilator. it is essential that Circuit should be highest quality in order to Ventilate patient correctly, efficiently and safely. Econ offers wide range of circuit with ISO standard connectors to suit most of the ventilator and humidifier, combinations. We can customize the product as per the individual need.
Medicate Valved Inhaler Spacer Specifications: Universal plug (compatible with all market firecrackers). It is available in three shade options small, medium and large â?? soft and non-toxic. Silicone valves, one-way on the nozzle. Capacity 250 ml . Description A spacer is a tube that attaches to the inhaler and holds the medication until you can breathe it in. This makes the device easier to use and helps get the medication into your lungs.
Medical Ventilator (Model SH300/PA900B/SH200A/) Ventilation specification Tidal volume l:E Monitoring specification VTI, VTE , MV, MVspn Fspn, Frequency, l:E Ppeak, Pmean ,Pplat, Pmin, PEEP Ã¥·³02 Compliance, Resistance P-T, F-T, V-T, P-V loop, V-F loop 20-2500ml Ventilation mode : VCV, VCV +Sigh, PCV, PRVC, SIMV+VCV, SIMV+PCV, SIMV+PRVC ,SPONT (CPAP/PSV) , BIPAP, APRV NIV/CPAP, NIV/PCV 1:10-10:1 lnspiratorytime: 0.1-12 s Pause time Pressure trigger sensitivity Flow trigger sitivity PEEP/CPAP Psupp Pinsp Phigh Plow 02 suction Ins.Hold Exp.Hold Manual ventilation Waveform Freeze: Yes Nebulization C02(optional) ETC02(optional) Optional Air compressor Humifier Support arm 0-50% (PEEP-20 to OcmH20) 1 - 20LPM 0- 50cmH20 0- 70cmH20 5- 70cmH20 21-100% 0- 70cmH20 1 00% 02 ventilation for 2mins 15s Max 15s Max 0-60 minutes adjustable CE
Product Paramenters Dimensions: 170mm x 180mm x 118mm 290mm x 180mm x 134mm Weight : 1.5kg 2.5kg (with the humidifier) Water Capacity: 350ml at recommendadwater level Ramp the ramp time ranges from 0 to 60 mintes Humidifier Setting off, 1 to 5 (90 �°F to 167 �°F/35 �°C to 75 �°C ï¼? Output No less than 10 mg H20/L Sp02 Range: 0 to 100% Pulse Rate 40 to 240 BPM AC power Consumption 100 -240 VAC, 50/60 Hz Max 2 A
Oxygen Ventilator