Reusable long life built in flow sensor
Selectetec with dual vaporizer can be
installed Built in 6 airway monitor
Flowmeter four tubes (O2, Air , N2O)
Rebreathing system (Co2 absorber )
Silicone / reusable patient circuit
Patient circuit holder Arm Low Flow ,
Minimal Flow with all accessories Horizontal Ventilation
with Bag in bottle System
Volume control ,
Pressure Control,
SIMV, VS, Spontaneous and manual ventilation Modes
Tidal volume compensation ,
Resistance compensation ,
Compliance compensation
Automatic leakage compensation
Anti Baro,
Anti Volume
trauma feature
Infant with the same system , pediatric ,
adult use
Advanced alarm system 10 1600 ml
Tidal Volume Adjustment APL Safety Valve and FiO2
monitoring
Electronic PEEP 0 20 mbar
4 hours internal battery
Optional vaporizer
Turkish user menu
Features: * The boosting pipe is compatible with standard 1.80ML local anesthetic and two models of syringe needles (British system and metric system). It is mainly used for local anesthesia injection of oral cavity. * There is no pipeline or other consumables, which may save the anesthetic and save the clinical cost. * There is no foot switch, just operation via pen holding; it can be operated simply while the first finger touches the sensor. * The unique design combines the pen holding type with the one-button operation perfectly, brings easier operation for doctors. * Low noise with melodious music. * The LCD display screen shows the operational process and dosage visually. * Non-contact of induction charging.
Features: * The boosting pipe is compatible with standard 1.80ML local anesthetic and two models of syringe needles (British system and metric system). It is mainly used for local anesthesia injection of oral cavity. * There is no pipeline or other consumables, which may save the anesthetic and save the clinical cost. * There is no foot switch, just operation via pen holding; it can be operated simply while the first finger touches the sensor. * The unique design combines the pen holding type with the one-button operation perfectly, brings easier operation for doctors. * Low noise with melodious music. * The LCD display screen shows the operational process and dosage visually. * Non-contact of induction charging.
ARIES 2500 Anesthesia Machine: Display: 10.4 TFT color screen Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi~open, Semi~closed or closed system Anesthetic vaporizer: two high precise vaporizers Power supply: 220V,10%, 50Hz,1Hz 10V,10%, 60Hz,1Hz Internal battery: DC12V (4 working hours) Fresh gas outlet is in front of frame Anesthesia Ventilator: Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO Waveform: P-t, F-t, V-t, F-v, V-p Tidal Volume: 20~1600ml Respiratory frequency: 1~65bpm I:E ratio: 4:1~1:4 Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc.. Alarm parameters: high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. Pressure alarm setting: High pressure alarm set 1~60cmH2O. Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high: 21~99%. Low: 21~50%. MV alarm setting: MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit: Circle absorber: Compact circle absorber Flow meter: Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min. N2O tube: 0L/min~1L/min~10L/min. Air tube: 0L/min~10L/min O2 and N2O Linkage Device, keep oxygen concentration not lower than 25% Oxygen flush: 25L/min~75L/min Gas source pressure: O2: 0.25Mpa~0.65MPa N2O: 0.25Mpa~0.65MPa Air: 0.25Mpa~0.65MPa Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Special Feature: Ventilation method: Closed, half-closed, half-open Small and compact unit ideal for office based anesthesia Two-gas machine( N2O&O2 ) Mechanical Anti-Hypoxic Device and O2/N2O interlock External CO2 circle absorber system Vetilator (option): TH-1, TH-1 A Main Unit: Tidal volume( Manual Mode): 20 ~ 1500ml Gas pressure: 0.25 ~ 0.65Mpa Flowmeter: O2 :0.1 ~ 10L/min N2O:0.1 ~ 10L/min APL valve: 0.5 ~ 6.0Kpa O2 Flush: 25 ~ 75L/min Ventilator TH-1 Special Feature: Driven mode: Pneumatically driven electronically controlled Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal volume: 50 ~ 1500ml Breath frequency: 1~ 90Bpm I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, airway pressure Alarm: MV high alarm£¬MV low alarm, TV high alarm, TV low alarm Ventilator TH-1(A): Special Feature: Respiration mode: IPPV, SIMV, MAUAL Display: 5.5¡¯ SNT screen Waveform: P-t, V-t Tidal volume: 50 ~ 1600ml Breath frequency: 1~ 65Bpm I:E ratio: 8:1 ~ 1:8 Alarm parameters: High pressure alarm, Low pressure alarm High pressure alarm limit: 20 ~ 60cmH2O Low pressure alarm limit: 0 ~ 20cmH2O Monitor parameter: Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I:E ratio Safety valve pressure limit: 6Kpa Good air tightness, high reliability, and minor respiration impedance.
Special Feature: Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi-open, Semi-closed or closed system Anesthetic vaporizer: One vaporizer Anesthesia Ventilator: Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal Volume: 50 ~ 1600ml Breath frequency: 1 ~ 90BPM I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm Main Unit: Circle absorber: Compact circle absorber Bellow: 50 ~ 1600ml Oxygen FLUSH: 25L/min ~ 75L/min Flow meter: O2, N2O two-tube flowmeter O2 tube: 0L/min ~ 10L/min N2O tube: 0L/min ~ 10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Gas source pressure: O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge: 2 units, one N2O, one O2.
An endobronchial tube is a medical device designed for use in the respiratory system, specifically within the bronchial tubes. These tubes are used in various medical procedures, such as bronchoscopy, endobronchial intubation, and lung surgery. The primary purpose of an endobronchial tube is to maintain an open airway and facilitate the delivery of oxygen or anesthesia to the patient's lungs during surgical or diagnostic procedures. Key features and uses of endobronchial tubes include: Bronchoscopy: Endobronchial tubes are often used in bronchoscopy procedures, allowing physicians to visually examine the bronchial tree and perform diagnostic or therapeutic interventions. Lung Surgery: During certain lung surgeries, endobronchial tubes may be employed to isolate and collapse one lung, providing a clear field of view for the surgeon. Ventilation: Endobronchial tubes can be used for selective lung ventilation. They can be positioned to direct ventilation to a specific lung, allowing the other lung to be collapsed or isolated. Anesthesia: In some cases, endobronchial tubes are used for delivering anesthesia during thoracic surgeries or procedures.
Teleflex: Teleflex is a global provider of medical technologies, including products for vascular access, anesthesia, respiratory care, surgical care, and more. They offer a range of vascular products, and the Arrow brand is associated with vascular access and intervention. Rediguard IAB (Intra-Aortic Balloon): Intra-aortic balloon pumps are medical devices used to temporarily support the heart's pumping function and improve coronary artery blood flow. The term "Rediguard" suggests that it may have features related to safety or guarding.
Supplier: Disposable surgical and anesthesia devices, like disposable anesthesia breathing circuit, disposable stainless skin staple remover, disposable pressure transducer, disposable breathing filter, soda lime (carbon dioxide absorbent), disposable electrosurgical pencil