The threaded sealing cap prevents liquid from leaking and can store high-purity reagents and standard samples in a sealed manner for a long time. It is widely used for digestion of new semiconductor material experimental samples and sample dissolution at medium and low pressures, supporting trace analysis experiments such as ICP-MS/ICP-OES analysis.
PFA, perfluoroalkoxy resin, is a special polymer material. In laboratories, PFA gas washing bottles are often used for gas purification and drying. Because its inner wall is smooth and difficult to adsorb gas molecules, it can effectively remove impurities and moisture in the gas and ensure the accuracy of experimental results. In petrochemical, semiconductor manufacturing, environmental protection and other industries, PFA gas washing bottles are widely used for gas pretreatment to ensure gas quality during the production process. In addition, PFA gas washing bottles are often used for gas storage and transportation. Due to its material characteristics, PFA gas washing bottles can maintain good performance in high or low temperature environments, ensuring gas stability and safety. #reactionbottle #gaswashingbottle #gascleaning #gaspretreatment
The PFA separatory funnel is mainly used in solid-liquid or liquid-liquid reaction experiments to control the amount of liquid added and the reaction rate, as well as material separation and purification, and to separate the two immiscible liquids formed after extraction. #separatoryfunnel #Solublepolytetrafluoroethylene #ICPMS #ICPOES #traceanalysis
The surface is treated with imported high-purity PFA anti-corrosion non-stick coating. It is a professional experimental hotplate for sample heating, digestion, evaporation, boiling and acid removal.#samplepreparation
Can meet the low detection limit requirements of ICP-OES and ICP-MS and provide laboratory-grade ultrapure acid for demanding analysis applications. The main body of the equipment is made of high-purity PTFE and PFA, and the container in contact with the acid reagent is made of imported PFA material. , lower background, no corrosion, no pollution, can handle HNO3, HCL, HF and other commonly used acids in laboratories. Experiments have shown that after a single distillation of an acid with a metal impurity content of about 10PPB, the metal impurity content can be reduced to about 0.01PPB. If the acid requirements are higher, the purification times can be increased. It is often used to extract high-purity acid in Ultra clean laboratories, trace analysis laboratories, geochemistry, marine systems, geology and minerals, geological brigade, polysilicon, materials and other industries. #Geochemistry #ICPMS #acidpreparation #acidpurification #traceanalysis
Molded from chemically resistant perfluoroalkoxy resin, this beaker features a thick-wall design suitable for continuous use in the laboratory.Suitable for trace and ultra-trace analysis and isotope analysis laboratories. #beaker #teflonlabware #samplepreparation #ICPMS
Used for the preparation of ultrapure acids in trace analysis, it can meet the low detection limit requirements of ICP-OES and ICP-MS and provide laboratory-grade ultrapure acids for demanding analytical applications, such as HNO3, HCL, HF and other commonly used laboratories. acid. #aciddistillation #ultrahighpurityacid #subboiling #acidpurification
PFA gas washing bottles are widely used. Prepare gas, collect gas, remove gas impurities, test gas, measure gas. In experimental devices with flammable gas sources, gas wash bottles can also function as safety bottles.
A 1/4-inch conduit can be connected to the lid to connect other reaction devices. PFA reaction bottles can store standard reagents for a long time, and large-capacity reaction bottles can be used for cleaning containers. #reactionbottle #Vialscleaningvessel #samplepreparation #teflonlabware
Can be matched with: PTFE stirring paddle, thermometer, condenser tube, heating jacket, air inlet, feeding port, discharge valve, etc. #reactor #reactionvessel #Petrochemical #Buchnerfunnel
It has excellent chemical resistance and can withstand strong acids and alkalis, such as nitric acid, aqua regia, etc. The position of the lower outlet valve and the liquid level gauge can be customized. High temperature resistance: -200 to +250. Both 30L and 50L can be customized.
The PFA ion exchange column has a Teflon sieve plate and is more durable without welding. This storage turntable effectively solves the placement problem. #Isotopeanalysis #ICPMS#resinseparation #teflon Mobile: +86-153 6614 0844 Wechat/Whatsapp: +86-153 6614 0844 Mail: ClairBZH@gmail.com
A variety of specifications are available, and external necks and valves can be customized as required. Below the device are connected a Buchner funnel, a filter bottle and other suction filtration devices. PTFE material is resistant to strong acids and alkalis and high temperatures. #Reactor #Stirringdevice #Suctionfiltration #reactiondevice#teflon
The PTFE threaded cap can be customized with a variety of interfaces, and can be connected to joints, PFA conduits, separatory funnels, etc. to form a reaction device. PFA Jar is available in various specifications: 60, 90, 120, 150, 180, 240ml...4,6L. #reactionbottle #PFAJar #digestionvessel Mobile: +86-153 6614 0844 Wechat/Whatsapp: +86-153 6614 0844 Mail: ClairBZH@gmail.com
It is often used in trace analysis, ultra-trace analysis, ICP-MS analysis, isotope analysis and other research industries; it can separate HF, the inner wall has no adhesion or adsorption to solvents, and can be completely drained. #ICPMS #separatoryfunnel #traceanalysis #isotopeanalysis
Teflon balls can be added to the tube to increase the reflux area; it can be directly connected to a flask and constant pressure dropping funnel to form a condensation reflux device; common specifications: 250, 300, 350, 500ml, larger specifications can be customized. #distillationcondensation #Refluxdevice #teflon #flask #labware
The specifications and styles of the reaction bottles can be customized according to the needs; PFA hoses can be connected to other reaction vessels as absorption bottles and collection bottles; the neck of the bottle cap adopts a thread sealing design to ensure the airtightness of the container. #samplepreparation #ICPMS #PFAbottle #labware #geochemistry
The bottle cap and bottle body are both made of high-purity PFA material; there are three bottom designs: flat, round, and conical; Can be used with a hotplate for sample digestion. #PFAVials
It can be used as a gas absorption bottle to connect to various reaction devices. The bottle contains Teflon filter balls. Multiple units can be connected in series as gas filtering devices to make the gas cleaner. 30-4000ml multiple specifications available from stock. #teflon #labware #PFABottle #gaswashbottle #gasabsorption
Used for the connection of laboratory equipment in the chemical industry, semiconductor, pharmaceutical industry and other industries. Connect pipes of different diameters to achieve medium transportation and flow control.