The PFA cleaning tank, also known as an acid tank, acid bath, square tank, or acid pickling tank, is a high-performance cleaning device specifically designed for industries such as semiconductors, photovoltaics, and optoelectronics. It is produced through integral molding using imported high-purity PFA raw materials, eliminating the risk of leakage. This cleaning tank can be used for storing high-purity reagents, cleaning wafers and chips, and placing on electric heaters to steam and clean laboratory utensils.
This purifier utilizes high-performance perfluoroalkoxy polymer (PFA) material to ensure exceptional chemical inertia, high temperature stability, and low permeability during acid processing. Its large-capacity design (1000ml) is suitable for batch processing, efficiently removing impurities from acid solutions to enhance solution purity and meet strict quality control requirements. Suitable for semiconductor manufacturing, electronic materials, chemical analysis, laboratory research, and other fields, particularly in processes requiring the preparation and purification of high-purity acid solutions, such as semiconductor cleaning, etching of electronic components, and chemical synthesis.
Premium Material: Constructed with high-performance PFA material, it offers outstanding chemical inertness, suitable for a variety of corrosive chemicals, ensuring long-term stability and reliability. Precise Graduations: Precisely calibrated graduation lines provide accurate volume readings, meeting the needs of high-precision experiments, reducing errors, and enhancing the accuracy of experimental results. Volumetric Design: The unique volumetric design facilitates quick and accurate adjustment to the desired volume, simplifying operational procedures and improving work efficiency. High Transparency: The high transparency of PFA material allows for clear visibility of solution status, making it easy to observe solution color, clarity, and other characteristics. Wide Temperature Range: With a broad operating temperature range, it maintains stable physical and chemical properties even under high or low temperature conditions. Application Scenarios: Suitable for chemical analysis, biological experiments, environmental monitoring, pharmaceutical research and development, and other fields, especially in experiments requiring high-precision volume measurements, such as solution preparation, titration analysis, sample dilution, etc.
Superior Material: Utilizes high-quality PFA material with outstanding corrosion resistance, high temperature tolerance, and low surface tension, effectively preventing wafers from any form of contamination during cleaning. Precision Design: Specifically designed for 2-inch wafers, the basket's compact structure and reasonable spacing between wafers ensure that cleaning fluid can fully reach every corner of the wafers, enhancing cleaning efficiency. Optimal Capacity: Capable of holding 25 wafers at once, meeting the needs for batch cleaning while maintaining operational convenience and improving work efficiency. High Durability: The PFA material boasts extreme wear resistance and longevity, maintaining the basket's integrity and functionality even after long-term use and frequent cleaning. Broad Compatibility: Suitable for various wafer cleaning equipment and chemical cleaners, ensuring optimal performance across different cleaning environments. Application Scenarios: Ideal for wafer cleaning processes in the semiconductor manufacturing industry, particularly in situations requiring high precision and efficiency, such as integrated circuit manufacturing and MEMS sensor manufacturing.
The PFA 100ml reagent bottle is primarily used for trace analysis, isotope detection, ICP-MS/OES/AAS analysis, and other experiments. Its low background value (with metal elements such as lead and uranium content less than 0.01ppb) and non-dissolution and non-extraction characteristics make it suitable for storing and packaging high-concentration, strongly corrosive drugs, chemical reagents, and standard samples. For example, it is used by the National Marine Bureau for storing ocean water standards and mercury standard solutions, and by the Antarctic Scientific Expedition Team of the University of Science and Technology of China for sample collection. Mobile: +86-153 6614 0844 Wechat/Whatsapp: +86-153 6614 0844 Mail: ClairBZH@gmail.com
PFA conical triangular flasks are generally used in titration experiments. To prevent the titration solution from splashing out of the bottle and causing experimental errors when dropped, place the bottle on a magnetic stirrer and stir. You can grip the bottleneck with your hand and shake it with your wrist, stirring evenly. Containing reactants, quantitative analysis, reflux heating, its appearance makes it suitable for these tasks. In addition to adding a stopper to the long neck, it can also slow down the loss during heating and prevent the overflow of chemicals. #Erlenmeyerflask #Conicalflask #reactionvessel
Digestion tube holder for CEM 110ml The holder can be placed in a fumehood to hold digestion tubes. Can withstand corrosion from strong acids and alkalis. There are handles at both ends of the holder to facilitate the transfer of the digestion tube. Different sizes of holders can be customized according to different brands and specifications of digestion tubes. #microwavedigestiontube #digestionvesselholder #Cleanlaboratory #MARSXpress
Perfluorinated digestion vessel for use in ovens Mainly used to digest insoluble substances in a high temperature, high pressure, closed strong acid or strong alkali environment.#digestionvessel #analyticalchemistry #samplepreparation
The bottle cap and nozzle are molded in one go with no welding gaps and no liquid leakage; High purity perfluoroalkoxy resin (PFA) is resistant to strong corrosion; Fast liquid reflux, smooth material, no residual liquid; Can be controlled to add liquid in a droplet shape. #washingbottle #labwarecleaning #chemicalresistance