CHEMAT Technology, Inc. Has designed and manufactured a compact and easy-to-use spin-coater, Model KW-4A, for precise and uniform deposition of thin films and coatings. Its rugged, vibration-free and portable design makes it a versatile tool for your research facility. A two-stage spin process allows dispensing at low speeds and homogenizing the coating at high speed. The KW-4A spin coater can be used to deposit metal oxide thin films, polymer coating and organic thin films. 2-Stage Spinning Stage 1: 500-2, 500 rpm 2-18 Seconds Stage 2: 1, 000-8, 000 rpm 3-60 Seconds. Power 115 VAC, 60 Hz, 1 Amp 220 VAC, 50 Hz, 1 Amp Vacuum: > 2.1 CFM Speed Stability:
CHEMAT TECHNOLOGY, INC. Has designed and manufactured a compact and easy-to-use hotplate, Model KW-4AH, for baking and curing thin films and coatings. Its rugged, portable design, and temperature uniformity make it a versatile tool for research facilities. In conjunction with KW-4A spin coater, KW-4AH hotplate can be used to fabricate metal oxide thin films, polymer coatings and metal organic thin films. Operation: Manual Load Process Control: Program (For details see OMRAN operation manual) Temperature fluctuation: 1C Temperature uniformity: 3% Temperature Range: ¡ª30C - 350C (KW-4AH-350) ¡ª30C - 600C (KW-4AH-600) Substrate Size: ¡ª7.5 inch X 7.5 inch(KW-4AH-350) ¡ª5.8 inch X 5.8 inch(KW-4AH-600) Inert gas purge (KW-4AH-600 only).
UV curing is a photochemical process by which monomers undergo curing (polymerization or cross inking) upon exposure to ultraviolet radiation. A specially formulated monomer will polymerize when exposed to ultraviolet radiation. This UV "curable" monomer includes a sensitizer which absorbs UV energy and initiates a polymerizing reaction in the monomer. KW-4AUV is specially designed for curing photosensitive coatings and thin films. It equips two UV light sources with radiations at 365 nm and 245 nm. The coated substrates up to 6?in diameter will be rotated at 6 rpm to ensure uniform curing. The built-in interlock door to prevent the exposure of UV radiation gives safe operation. In conjunction with the KW-4A spin coater, the system can be used to make various coatings and thin films via the photochemical process.
Specifications : Wavelength range : 190-1100nm Spectral Bandwidth : 2nm (5nm, 4nm, 1nm Optional) Wavelength Accuracy : ± 0.3 nm Wavelength Reproducibility : 0.15 nm Photometric System : Double beam, auto scan , Dual detectors Photometric Accuracy : ± 0.3% T (0-100%T), ± 0.002A(0~1A) Photometric Reproducibility : 0.15%T Working mode : T, A, C, E Photometric Range : -0.3, -3.5A Stray Light : 0.1%T (Nal, 220nm, NaNO2 340 nm) Baseline Flatness : ±0.002A Stability : 0.001A/h (at 500nm, after warming up) Noise : ±0.001A (at 500nm, after warming up ) Display : 6 inches high light blue LCD Detector : Silicon photodiode Power : AC:220V/50Hz, 110V/60Hz, 180W Dimensions : 630X470X210mm Weight : 26Kg.
SPECIFICATIONS: Wavelength Range: 190-900nm Wavelength Accuracy: ±0.25nm Resolution: Two Spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30% Baseline Stability: Background correction: The D2 lamp background correction capability at 1A is better than 30 times. !0.004A/30min. Light Source: Lamp turrel: 6-lamp turret RIC-114/ RIC-113 4-lamp turret RIC-112 Auto-alignment, fully automated scan and peak-picking Lamp current adjustment: Automatic adjustment and display. Wide pulse current: 0~25mA Narrow pulse current: 0~10mA Lamp power supply mode: 400Hz square wave pulse 100Hz Narrow square wave pulse + 400HzWide Square wave pulse (RIC-114/ RIC-113) Optical System: Monochromator: Single beam, Czurney-turner design grating monochromator Grating: 1800l/mm Focal length: 277mm Blazed wavelength: 250nm Spectral bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change Flame Atomizer: Burner: 10cm single slot all-titanium burner Spray chamber: Corrosion resistant all-plastic spray chamber Nebulizer: High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7mL/min Detection and Data Processing System: Detector: R928 photomultiplier with high sensitivity and wide spectral range Software:Windows Operating System Analytical method:Window curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content. Repeat times: Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation Multi-task function: Sequential measurement of multi-elements in one sample Condition reading:With model function Result printing: Measurement data and final analytical report printout, editing with excel. Standard RS-232 serial port communication Characteristic Concentration and Detection Limit: Normal Air-C H flame: Cu Characteristic concentration Rich oxygen Air-C H flame: Ba: Characteristic concentration Function Expansion: Hydride vapor generator can be connected for hydride analysis. Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg. Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg.
Origin:Zhejiang China Specification:11.6*32mm Volumn:1.5ml Material:USP 1 expansion 30 Parkage:100pcs Delivery time:within 7 days Prompt delivery OEM:accepted Certification:ISO 9001 Packing:sealed/outer:carton/special ordering requirement accepted. Packing: sealed/outer:carton/special order accepted Weight: 0.6kg/pack(100pcs).
Metering mode: Double-beam C-t optical structure, blazed holographic grating, photomultiplier tube detection Wavelength range:190nm-1100nm Resolution:better than 0.15nm Spectro bandwidth:1.8nm Wavelength accuracy:0.3nm(with automatic wavelength calibration device.) Wavelength accuracy:
Temperature control range: 7¡æ-400¡æ of room temperature (increment by 1¡æ) Temperature control objects: column, ion chamber, thermal conductivity, sampler A, sample B, auxiliary (standby) Temperature programming phase: five Temperature programming rate: 0.1¡æ-40¡æ£¯min(increment by 0.1¡æ) Flame Ionization Detector (FID) Sensitivity : M¡Ü1¡Á10-11g/s(sample:l C16) Optimal test result: M¡Ü5¡Á10-12g/sl.
Features: 1. Temperature measurement range: 0-40(32¨h - 104¨h) 2. Precision ¨h measurement temperature:¡à1(2¨h) 3. Measurement temperature resolution: 1(1¨h) 4. Operation temperature:0 ¨c35(32¨h-90¨h) 5. Storage temperature: 0 ¨c50(32¨h-122¨h) 6. Dimension:135¡á65¡á40mm 7. Weigh:200g 8. Power supply: 2¡áaaa(1.5v) 9. Operating time: more than 2000 times per battery 10. Automatic temperature compensation 11. Automatic shut ¨h 12. Conversion between centigrade and fahrenheit degree 13. Alarm ¨h low voltage Propylene glycol Range: 0~50 Accuracy: 0.1 Divisions: 0.1 Ethylene glycol Range: 0~-50 Accuracy: 0.1 Divisions: 0.1 Battery Range: 1.00~1.50sg Accuracy: 0.01sg Divisions: 0.01sg Cleaner Range: 0~-40 Accuracy: 0.1 Divisions: 0.1.
Main features: It has been assessed and registered as meeting the requirements of ISO9001 and 14000. With Italian fuel injection system Automatically control system, digital display Time set, automatically incinerate and ignite Vacuum burning, fuel is diesel fuel Can meet the requirements of the national environmental protection standard. Low failure rate, low maintenance and running cost Technical parameter: Model Capacity Fuel Sampling Methods Power Power Supply JK-MI-10 10Kg/H Diesel fuel Automatically 700W 220V/50HZ JK-MI-20 20Kg/H Diesel fuel Automatically 900W 220V/50HZ JK-MI-30 30Kg/H Diesel fuel Automatically 1100W 220V/50HZ JK-MI-50 50Kg/H Diesel fuel Automatically 1800W 220V/50HZ.
Singh Science Systems gives a good faith to customers, our super plus model is very atractive design & good eccuracy Click-stop digital systems, click sound at each increment during volume setting ensures no superfluous volume variation during pipetting. Strong & latest design, frivolous weight and soft plunger movement provides conform and reduces hand fatigue. Use for long life & easy tip ejecting technology. Ultimate for genetics & biotech application, tissue culture cellular & molecular biology laboratories, hospital, quality control & research labs. Easy volume setting by simply spinning the plunger. Easy and smooth, operation does not rip up hand gloves. Companionable with all major make of tips. Accuracy and precision both are guaranteed. Autoclavable tip cone. (Partially Autoclavable). Each pipette has a calibration report, ensure pre-dispatch quality check.
39- liters laboratory flotation machine is applied in ore dressing by the method of laboratory floating. It is concatenation floatation machine with several sets of machines. And the number of chutes is even from 1 to 10. It is left-type or right-type according to user's demand. Structure and features: Laboratory flotation machine with 39 liters is impeller mechanical flotation machine. It is composed by the following main parts: (1). Tank The tank 1 is welded with steel plate, using the impeller to stir, simultaneously inflating the air into pulp. In order to adjust the thickness of slurry surface in tank and foam layer scraped, the intermediate tank 15 is made up of two slot panels, in which is the pulp surface regulator 5 installed, orifice 17 is installed on the tank cover 14, which is used to prevent the chaotic movement of pulp affects on the bubble zone, the gangue is entrained mechanically to the concentrate. Basin liner 6 is equipped in the tank to prevent the tank bottom worn, basin liner can be replaced. Discharging port 8 is placed outside the tank bottom, which is used to storage water when cleaning. The pulp flows into the intermediate tank 15 and the end tank 3 from the overflow port on the panel, the catheters of the intermediate tank bottom and the cover 14 on the groove wall bottom are put into the next tank, which will flow continuously through all the tanks of flotation machine. The pulp is fed from the feed chute 3, is discharged from the discharging port 8 of the tailing 1, the feed port 16 is equipped in front and at the back of tank bottom, which is easy to change the technological process. (2)Impeller system Impeller system is installed in the center of the flotation tank, the vertical arrangement coiled impeller 9 which leaves are up is fixed at the bottom of the impeller shaft 10 and around the vertical shaft tube 12. The tube top is located over the pulp stone and foam layer, the tube bottom is bearing the cover 14. When the impeller rotates, the quantities of air can be absorbed along the vertical tube 12. The protective plate 4 is fixed under the cover 14, the gap between the protective plate and impeller is related to the aeration rate, its maximum gap is less than 3mm, if the gap is too large, it is necessary to replace the protective plate or be adjusted appropriately. The hole of vertical tube 12 is used to cycle pulp, and make the pulp and air mix well. The upper of the impeller shaft rotates in the rolling shaft 11 installed in the bearing shell, the bearing shell is installed on the beam 7. The pulley fixed at the top of the shaft makes the motor 18 rotating through the triangle belt, of which the tension can be adjusted by the nut 19. (3). Shaving foam device Foam is scraped using the rotary scraper along the flotation machine, scraper 20 is installed out of the discharging port. The pulley is installed at the end of the scraper shaft, which rotates through the driving of the worm reducer 21 and V-belt. Technical parameters (1)Tank size: L¡ÁW¡ÁH 315¡Á315mm¡Á527mm (2)The effective volume: 39 liters (3)The flow of the pulp is calculated according to the production capacity (4)Aeration rate: 35-45 liters / min (5)Impeller diameter:200mm (6)Impeller speed: 809m/s (7)Impeller circumferential speed:8.14m/s (8)Scraper rpm: big wheel/small wheel 21r/min /13r/min (9)Motor: Model y900l-4 voltage :220/380V. Power:1.5KW rpm: 1400 r / min (10)Assembly method: Left-style (11)The outline size of machine: H: 930mm, W: 762mm, L (including 2 slots)1081mm (12)Total weight:(including 2 slot motors).
ZY6014A (Vertical-specimen) Flame Tester 1.Introduction: This apparatus is certificated by Guangzhou Hua Mei UL company ,it applies to research and manufacture for illumination, household, machine tool, motor, and such electric and electronic equipments and parts. It is also used to insulation materials, project plastics and other materials. 2. Standards: UL1581(section 1080.1£1080.14) , UL13. UL14 UL1655(VW-1 burning test). CSA (FT-1¡¢FT-2) 3. Main components: burning chamber ¡¢observation Windows¡¢ operation windows¡¢control system ¡¢gas control and so on . 4. Main parameters : 4.1 Burning chamber outside size: 2.4m(L)*1m(W)*2.5m(H) 4.2 Observation Windows: 3 observation Windows, made by reinforced glass, size: 730mm(H)*420mm(W) 4.3 Operation windows: 4 operation windows, interior diameter 150mm, outside diameter 220mm.sealed by 600mm long-arm leather glove. 4.4 Air inlet : 4 air inlets ,which diameter is 160mm, 4.5 Bottom anchor : bottom anchor size 2.4(L)*1m(W)*0.7m(H), 6 pulleys of which 4 are with lock. 4.6 Light equipment : 1 anti-fog,anti-smoke,ring lamp. 4.7 Control system: 1 sheet of burning instrument, 0 to 99.99s setting arbitrarily. 1 sheet of stop burning instrument, 0 to 99.99s setting arbitrarily . 0 to 999999 times setting arbitrarily. negotiable
ZY6056 Needle Flame Tester 1. Introduction : This device applies to electrical and electronic equipment and components ,also suitable for electrical insulating materials or other solid materials ,using simulation technology assess dangerous of catching fire or flame driven from internal equipment under fault condition. 2. Standards: IEC60695-2-2. GB/T5169.5-1997. 3. Main components: needle combustor, temperature measurement system , test chamber and so on. 4. Main parameters 4.1 Burner :inner diameter 0.5mm, length 35mm. 4.2 Flame standard : length more than 12mm. 4.3 Heat speed :100 - 700C costs 2.5S 4.4 Chamber capacity 0.5M 60cm(L) * 95cm(W) * 90cm(H) 4.5 Conductive copper ¥Õ4.0 * 6.0mm, 4.6 Outsize :61cm(D) * 120cm(W) * 105cm(H).
ZY6078 Vulcanization Tester 1. Introduction : This device applies to show vulcanization curve , so that a new hand can easily get the best reasonable ingredients and balanceable formula of scorching and vulcanization by computer and software . 2. Main components : 2.1 Machine parts: cabinet , upper and bottom mould cavity ,and so on. 2.2 Electrical control system 2.3 Printer 2.4 Pneumatic system.
ZY 6192 Halogen Release Measurement Device 1. Introduction: this device applies to measure halogen content PH conductivity when wires and cables are burning according to IEC60754. 2. Standards:GB/T17650.1-1998, GB/T17650.2-1998, IEC60754-1:1994, IEC60754-2:1991 . GB/T19666-2005, GA306.1-2007, GA306.2-2007, UL2556-2007. 3. Main components : quarts material tubular furnace combustion tube, air collection system, air supply system , PH meter , conductivity analyzer 4. Main parameters: 4.1 Tubular furnace chamber size : 42mm * 600mm, power input :220V/10kw. 4.2 Combustion tube 40mm, 4.3 PH meter : precision 0.02PH. 4.4 Conductivity : measurement scope :(0~1¡Á105)¦ÌS/ cm. 4.5 Air flex meter :20-200L adjustable.
LK ¡§C210A Black -white Densimeter Features: This product uses circuits of high-tech products, working with the advantages of accurate measurement, good stability, convenient operation, etc. Parameter: Density range : 0 = 0.00-5.00 Light hole size : Dia 2mm Reading stability : about 0.02 Uncertainty : 0.00-3.00 0.02D, 3.00-4.00 0.04D, 4.00-5.00 0.08D Display form : 3 digits display Sampling time : 0.8s Working environment : 0 ¡§C 40, relative humidity
Hardness tester LK120 Features: Easy one handed operation Digital Display Compact body for areas of restricted space Slim detector allows measurements to be taken on complex curved surfaces such as welds, moulds etc, as well as conventional flat surfaces Conversion function for different hardness scales Self calibrating Supplied with NAMAS certified test piece Used in any direction Lightweight, portable and easy to carry Using large-screen 128 * 64 dot matrix LCD module, information abundant and intuitive. Can be pre-set limit, hardness, when beyond the scope it automatic alarm, convenience customers batch test. English display: menu type operation, uses simple and convenient. Technical parameter: Measuring scope: HLD (170-960) HLD Measuring direction: support plummet, inclined, level, oblique, pure vertical measured material: Steel ,alloy steel, stainless steel, grey cast iron, ductile iron, zinc alloy, copper alloy ,casting of copper, , Copper alloy (brass, bronze), pure copper, forged steel . Hardness formats: HL,HB, HRB, HRC,HRA,HV,HS Display: high contrast segment code type LCD display Data storage: maximum 500 groups (impact times: 32-1) Paper width: 57.5¡À0.5£©mm Paper coil diameter: 30mm Work voltage: 6V Nimh batteries Work Time: about 150h, With power saving function like auto dormancy, automatic shutdown etc. Measuring direction: 360¡ã operating temperature: -10 ~ +50¡æ Shape dimension:213*80*215mm relative humidity:
Table-top high speed refrigerated centrifuge.
Floor-type/table-top high speed refrigerated centrifuge.