Electronic Digital Liquid Level Indicator Manufacturer & Exporter of Electronic Digital Liquid Level Indicator & Digital Level Indicator. Our product range also comprises of Glass Tube Rotameter, Acrylic Body Rotameter and Bypass Rotameter. Digital Level IndicatorWe are supplier & exporter a range of Electronic Digital Liquid Level Indicator which indicates and controls the level of water accurately. Offered range of indicators is manufactured under the guidance of qualified and enthusiastic professionals who work in close bonds to come up with a durable range. Sturdy unbreakable mechanical loss of head indicators is also present in this equipment. Applications: Ideal level management system for Industrial water - DM, Dl, water plants, utilities Oils-fuel, Lubricating, edible, cosmetics Dyes and chemicals Breweries, distilleries Pharmaceutical, solvent extraction food processing dairy plants Some features are: Low maintenance Resistance against corrosion High tensile strength Robust construction
Acrylic Body ManometerOur customers can avail from us a wide range of Acrylic Body Manometer. We are reputed for the Acrylic Body Manometer that are offered in aluminum casing from three sides with see through acrylic front. Owing to their modern and user friendly features, these are widely used in various Schools, Colleges, Laboratories and other places. Acrylic Body ManometerAcrylic Body Manometer is defined as a force per unit area - and the most accurate way to measure low air pressure is to balance a column of liquid known weight against it and measure the height of the liquid column so balanced. The unit of measure commonly used are mm hg/inches hg using mercury as the fluid, and mm wc/inches wc using water or oil as the fluid. Features : The unit of measure commonly used are mm hg /inches hg using mercury as the fluid mm wc / inches wc using water or oil as the fluid.
Manufacturer & Exporter of Metal Tube Rotameter. Our product range also comprises of Glass Tube Rotameter, Acrylic Body Rotameter and Bypass Rotameter. With our expertise, we are able to put forth a wide range of Metal Tube Rota Meter, which is perfect for applications of high pressure, temperature and corrosive conditions. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area created by float position. Operating principles : The essential Working part is a tapered tube with an embedded magnetic float When flow occurs, the position of the float responds to flow driving a follower magnet outside the meter body, with no physical contact the meter works well with liquids gases even at elevated pressure and temperatures. FSD Series : Dial type read out Straight flow design No bends, no seals, no threaded joints Direct reading scale Compact, economical design Perfect safety Applications : Process treatment plant manufactures use this meter due to its ease of installation, perfect safety and easy maintenance. It may be used for monitoring flow of De-mineralized Water, Gases, Acid, Salts, Organic Solvents and most petroleum product. Meter Body SS 316l, SS 316, SS 304 etc Float SS 316L, SS 316, PTFE etc Indicator Housing ABS. Optional-Aluminum, SS-304 Temperature Rating 250 C Pressure Rating 40 Bar Accuracy +- 2 % Of Full scale Accessories Electronic transmitter with (steam jacket) 4-20m a O/P Accessories Digital flowrate indicator totaliser Accessories Hi- Low Flow switch
Being a client focused organization, we are instrumental in offering a commendable array of Rota Meter. Our products are widely used in Pharmaceutical, Chemical, Dyes & Pigments, Research and Educational Institutes all over India. Superior grade raw material is used in manufacturing of these products in accordance with the tastes and preferences of the clients. Prior to dispatch, we check these instruments so as to ensure their resistance against corrosion, fine finish, elegant look and strong construction. We are a quality focused organization engaged in offering a broad assembly of Rotameter or Glass tube rotameter, which is basically a variable area flow meter. Glass Tube Rota Meter, which is basically a variable area flow meter Some of the specifications are as follows : Standard Range: 200 mm to 2000 mm Temperature: Upto 200 C Pressure: Upto 20Kg/cm2 Moc: ss 304, SS 316, SS 316L, PP Connection: Flange End/Screwed Or To Mention
Top Mounted Magnetic Level Switch Manufacturer & Exporter of Top Mounted Magnetic Level Switch. Our product range also comprises of Glass Tube Rotameter, Acrylic Body Rotameter and Bypass Rotameter. Top Mounted Magnetic level Switch or liquid level switch moves up and down on probe immersed in a liquid. The float energizes the hermetically sealed sensors, which change from NO to NC or otherwise as the float - passes them. Details Require for Quotation : Height Of The Tank Or Probe Length Required No. Of Points To Be Controlled With Respect To Top Flange Material Of Construction Of Wetted Parts Top Nozzle Detail Which Is Welded On Tank On Which You Are Intenting To Mount Level Switch Housing Enclosure (Flame Proof/ Weather Proof) Features : Standard Range: 200 mm to 2000 mm Temperature: Upto 200 C Pressure: Upto 20Kg/cm2 Moc: ss 304, SS 316, SS 316L, PP Connection: Flange End/Screwed Or To Mention
Manufacturer & Exporter of Displacer Type Level Switch. Our product range also comprises of Glass Tube Rotameter, Acrylic Body Rotameter and Bypass Rotameter. Our organization is instrumental in offering a gamut of Displacer Type Level Switch. Our range is custom engineered in several specifications as specified by our clients. Displacer Type Level Switch is based on buoyancy principle. It is used for controlling the liquid level in underground & overhead tanks. Specifications : Application: Wat water, Furnace Oil, Lube Oil Chemical, Solve etc. Protection: Weather proof IP 65/Ex-Proof IIA & IIB Out Put: Relay contacts Switch Rating: 5 Amps 230v Ac Pressure: 20kg/Cm2 Temp. : 150 C Conn. : 3"(Min.) Flanged or Screwed Details Require for Quotation : Height Of The Tank Or Probe Length Required No. Of Points To Be Controlled With Respect To Top Flange Material Of Construction Of Wetted Parts Top Nozzle Detail Which Is Welded On Tank On Which You Are In-tenting To Mount Level Switch Housing Enclosure (Flame Proof/ Weather Proof)
By Pass Rotameters Manufacturer & Exporter of Bypass Rotameter. Our product range also comprises of Glass Tube Rotameter, Acrylic Body Rotameter. By- Pass Rotameter systems are designed for the accurate measurement of fluid rate of flow in pipelines 25 NB in diameter. They accomplished this by providing a bypass flow that is directly proportional to the main flow. Since Rota meter measure bypass flow, not static differential, flow ranges up to 10 to l are possible with these instruments. System - A complete bypass Rotameter installation consists of the following : Orifice flanges with orifice plate for insertion into the main pipeline Bypass piping with valves and fittings; a range orifice for insertion into the bypass pipeline What ever type Rotameter is considered best suited to a particular application Suitable to measure the Flow in above Specifications : Type of tapping: Flange, D and D/2, corner Accuracy: +/-2% of full flow Range ability: 7:1 or 5:1 50NB Line Standard ISO 5167 Size Design Standard: ISO 5167 or BS/1042 BS/1042 Accessories : High & Low Flow switches 4-20 ma Transmitter
Glass Tube Rotameter Manufacturer & Exporter of Glass Tube Rotameter. Our product range also comprises of Acrylic Body Rotameter and Bypass Rotameter. Our organization holds expertise in manufacturing and supplying premium quality Glass Tube Rota Meter. We carry out the manufacturing process of these Rota Meter by making use of the supreme quality steel under the supervision of professional. This equipment is made of qualitative range of boro silicate glass using the latest technology. Features : Flow Star Glass Tube Rota meters are unique design for industrial usage high precision tapered borosilicate glass tubes are utilized for best performances. Special design features eliminate stresses on glass tube even under industrial handling conditions. Glass Tube are field replicate without disturbing end connection
Heating Mantle
PTFE Parts
Glass plant and pipeline should be supported correctly. To prevent inducing undesirable stresses stresses in the glass, support should be rigid. When supported, glass should be in compression. Generally glass plant and equipment are supported in a rectangular tubular structure. This structure is formed of galvanized mild steel tubing with the cast iron fittings, which are described in this catalogue. This type of structure provides enough flexibility for future modifications and is strong enough to support a glass unit. Following rules should be followed while supporting a glass unit in a tubular structure. The structure be rigid. To give lateral support it must be braced back to the nearest wall or any rigid feature. All glass columns are build up from a fixed point on which whole weight of the column should be taken. If total loads exceeds the permissible limits, counter balance supports should be used to relieve excessive weight. With change in temperature, glass column and tubular structure expands at different rate. Therefore glass unit must be free for vertical movement above the fixed point. Hence above the fixed point guide supports should be used to give lateral support. Structure Tubes, Galvanised For forming the structure "B" class galvanised tubes are used in size of ½",1", 1¼", 1½", and 2. Cut tubes are available in required length to form a standard size structure. Cut tubes are provided with rubber plug at both the ends.
Column Components Measurement & Controls Column Components In many operations like reaction, extraction and absorption, the transparency of glass is a particular advantage. For such processes a range of column components are available in borosilicate glass which offers many advantages like : Inert to almost all chemicals hence no risk of contamination. Transparency allows visual monitoring of the process, flow patterns, colour changes etc. Almost universal resistance to corrosion Smooth surface permits easy cleaning and prevents fouling. Measurement & Controls In this part we have introduced equipment for efficient measure and control like Digital temperature indicators and controllers, Electro-magnet and timers for reflux control and Liquid level controller.
Product Description V945 1.5mL Amber Screw Neck Vial w/Write-on Spot, 9-425 Thread, 11.6*32mm, USP type 1 Features 1)9mm screw vials can be used on all common autosampler 2)Standard narrow neck design for GC and HPLC 3)9mm wider opening for easy puncture 4)Clear, type 1 class A borosilicate glass 5)9mm PTFE/silicone septa, has excellent chemical inertness, acid and alkali resistance 6)9mm screw black open top pp caps
Product Description 1.5mL small opening screw-thread vial amber glass vials V935 polypropylene autosampler vial manufactures septa Features 1)9mm screw vials can be used on all common autosampler 2)Standard narrow neck design for GC and HPLC 3)9mm wider opening for easy puncture 4)Clear, type 1 class A borosilicate glass 5)9mm PTFE/silicone septa, has excellent chemical inertness, acid and alkali resistance 6)9mm screw black open top pp caps
Measuring Jugs These handy jugs, molded in polypropylene, are clear, autoclavable and have good chemical resistance. These jugs are provided with a handle for easy & convenient lifting & have raised graduations for easy reading. Capacity ml Least Count 250 ml 10 ml 500 ml 10 ml 1000 ml 10 ml 2000 ml 20 ml
1. Application Ultraviolet aging test chamber uses ultraviolet lamp as light source. By simulating the ultraviolet radiation and condensation in natural sunlight, accelerated weatherability test of materials is carried out to obtain the results of weatherability of materials. It can simulate the environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation and darkness in natural climate. By reproducing these conditions, it can merge into a cycle and let it automatically execute the number of cycles. 2. Standards Conforms with ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE J2020, ISO 4892, all current UV aging test standards. GB/T14522-93 National Standard of the People's Republic of China--Accelerated Test Method for Plastics, Coatings and Rubber Materials for Machinery Industry Products-Artificial Climate GB/T16585-1996 National Standard of the People's Republic of China-Test Method for Artificial Climate Aging of Vulcanized Rubber (Fluorescent Ultraviolet Lamp) GB/T16422.3-1997 standard design and manufacture of plastic laboratory light source exposure test method. 3. Product Parameters Standard Configuration Editor For Test Box (1) Install 8 UV ultraviolet lamps on both sides of the studio. (2) Sample holder number: 20 pieces. (3) Sample holder size: 404 x 105 (mm) (4) The heating mode is inner tank water heating, fast heating and uniform temperature distribution. (5) The drainage system uses the return vortex type and U type sedimentation device to drain the water. (6) The distance between the surface of the sample and the ultraviolet lamp is 50 mm and parallel. (7) The actual workroom is made up of test samples and brackets. (8) Internal water level automatic replenishment. (9) The box cover is bidirectional flip type, easy to open and close. (10) The bottom of the test box adopts high quality and fixed PU wheel. 4. Power Supply Condition Editor Power requirements: AC380V ± 10% 50 ± 0.5Hz three-phase five wire system. Preinstalled power: total power +2.0KW Users are required to install air or power switches for the equipment at the installation site.
I. Application Xenon lamp test chamber uses xenon arc lamp which can simulate all sunlight spectrum to reproduce destructive light wave in different environment. It can provide corresponding environment simulation and accelerated test for scientific research, product development and quality control. Xenon lamp test chamber can be used to select new materials, improve existing materials or evaluate the durability of materials after composition changes in the test, is a good simulation of different environmental conditions that materials exposed to sunlight changes. 2. Standards GB/T16585-1996, GB14522-93, GB/T16422.3-97, ASTM D2565 Comply with GB/T16585-1996, GB14522-93, GB/T16422.3-97 and ASTM D2565 standards. 3. Main technical parameters 3.1Humidity deviation: + 2.5% R.H (Humidity75%R.H), + 3% R.H (Humidity 75%R.H) (without light) 3.2 Types of Light Sources: imported air-cooled all-solar spectral long arc xenon lamp (average service life of 1600 hours or so) 3.3 Rainfall time: 1~9999 minutes, adjustable. 3.4 Rain cycle: 1~240 minutes, interval (break) adjustable 3.5 Light source wavelength range: 300-800nm 3.6 Humidifying power: about 2KW 3.7 Light source irradiance: 290~800nm: 100~600w/m2 300~890nm: 200~1200w/m2 340nm: 0.3~1.2w/m2 420nm: 20~120w/m2 3.8 Distance between arc center to sample frame: 350 ~ 380mm 3.9 Rotating speed of sample basket: 1r/min 3.10 Water spray cycle: Water spray time: 0 ~ 99h59min, continuous adjustable Stop time: 0 ~ 99h59min, continuous adjustable. 3.11 Lighting time: continuous programmed control. External dimension W x D x H: 1050 x 1050 x 1750 mm Internal dimension W x D x H: 500 x 500 x 600 mm Temperature range 080 Temperature deviation ±2 (without illumination) Humidity range 30 ~ 98% R.H Spectral wavelength 300nm ~ 800nm Xenon lamp power 1.8KW Life span 1600 hours Blackboard temperature 85±3 Power About 4KW; 220V±10%, 50HZ
Stainless Steel Thermal Shock Test Chamber 1. Principles and methods It uses the low temperature and high temperature storage hot trough, according to the movement need, uses the cylinder valve to switch the cold and hot air, thus achieves the fast temperature impact effect, balances the temperature control system (BTC) + the special design supply air circulation system, controls the SSR by the P.I.D. method, causes the heating amount of the system to be equal to the heat loss, therefore makes it long-term stable use. 2. Main Parameters 1. Performance: wind cooling type at room temperature ±25, no load. (1) Impact temperature range: - 40 ~ 150 (2) Temperature setting range of high temperature cell: + 60 ~ + 200 The temperature rise time of the high temperature tank is about 35 minutes from RT (room temperature) to + 200 degrees (room temperature + 10 ~ + 30). (3) The temperature setting range of cryogenic tank is from - 60 to - 10 . The cooling time of the cryogenic tank is from RT (room temperature) to -60 , which takes about 90 min (room temperature + 10 ~ + 30 ). (4) Laboratory temperature: - 40 - 100 (5) Temperature fluctuation: ±1 . (6) Temperature uniformity: ±2 . (7) Shock recovery time: - 40 ~ +100 takes about 3 minutes (no load), (high and low temperature shock isothermal time is more than 30 minutes each).
I. Application 1.1 Dust-proof test box is designed and manufactured according to GB4208-93 (equivalent to IEC60529-2001) "Shell Protection Grade (IP Code)" and is suitable for sand and dust test of electrical products with the first characteristic digits of 5 and 6 (IPX5 and IPX6). 1.2 The test chamber can provide non-laminar vertical circulating airflow of dust, which can be controlled regularly. It is equipped with a vacuum pump to pump air into the outer shell of the tested product, and it can adjust the pumping volume and pressure difference.In addition,the air temperature control device is installed in the chamber to ensure that the test is carried out under the standard environmental conditions. 1.3 According to the standard requirements, this test chamber adopts the artificial analogy dust environment to test the dust-proof ability of the tested products, and its specific requirements and eligibility criteria should be in accordance with GB4208-93 (IEC60529-2001) or product-related standards. 2. Structure and Material Material: both inside and outside gallbladder adopt SUS high grade stainless steel plate door: tempered glass door. Sample outlet: dust-proof socket Controller: programmable controller (the controller has the following arbitrary setting control functions). A. Dust blowing time (stop and blow) h/m/s adjustable B. Cycle: arbitrary adjustable C. Preset test time: 0s to 999h99m99s arbitrary adjustable D. Power on: break through break Metal screen size: nominal diameter 50 um, nominal distance between lines 75 um Blower: all plastic centrifugal fan Vacuum system: equipped with pressure gauge, air filter, pressure regulating triple parts, connecting pipe (vacuum pump with another, when ordering instructions) Remarks: The test box can meet the requirements of protection grade test for household appliances, low-voltage appliances, automobile and motorcycle parts in GB2423, GB4706, GB4208, DIN. The device can not meet the sand and dust test in GJB150.
1. Application Salt spray corrosion test box is designed for surface treatment of various materials, including metal plating, hardware, electronic components, chemical coatings, baking paint, automobiles, motorcycles, hardware sanitary ware, screws, springs, magnetic materials, organic and inorganic skin film, anodic treatment, rust-proof oil and other industries, testing the quality of its products and its corrosion resistance. 2. Standards Conforms to ASTM G85-02 and GB/T2423.17 test standards. 3. Performance parameters Laboratory volume: 108 L, studio size: 600 * 450 * 400 mm Laboratory temperature: 35 ~ 0 The temperature of the saturated air cylinder is 47 to 63. Maximum capacity of test fluid: 15 L External dimension: 1075 * 630 * 1185 mm Can be customized according to customer requirements.