Cable Standard BS 6500 & IS 694:2010, IEC 60227 Silent Features - High flexibility - Excellent resistant to moisture, abrasion, grease, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130 Insulation PVC As Per IS:5831 Inner Sheath PVC Outer Sheath PVC As Per IS:5831 Core Color As per IEC 60227 3C -Blue, Brown, Black or Yellow/ Green, 4C -Blue, Brown, Black, Grey or Yellow/Green As per IS 694 : 2010 - 3C - Red, Yellow and Blue 4C - Red, Yellow, Blue and Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply.
Cable Standard DIN VDE 0282 PART 810, IEC 245 & BS 6007, BS 6899 Silent Features - Temperature range -40�° to +90�° - Excellent Impact Resistant - Excellent Weather Resistant Technical Data Operating Temp : Temp. range -40 to +90 Nominal Voltage : 1.1 KV Test Voltage : 2.5 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130, IEC 60228 Insulation EPR Rubber as per IS:6380, VDE 0282 (Part-1) Inner Sheath NBR/TPR Rubber as per IS:6380, VDE 0282 (Part-1) Outer Sheath : NBR/TPR Rubber as per IS:6380, VDE 0282 (Part-1) Core Color As per IEC 60227 3C - Blue, Brown, Black or Yellow/ green, 4C - Blue, Brown, Black, Grey or Yellow/green As per IS 694 : 2010 -3C - Red, Yellow and Blue 4C - Red, Yellow, Blue and Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps & Submersible Motor Power Supply.
Cable Standard According to DIN 72551-6 & ISO 6722 B JIS C 3406, JASO D 611/608, IS 2465, BS 6862 : PART 1 Cable Features - Excellent flexibility - The NESKEB Auto cables is impervious to water, petrol, diesel, acids, engine and lubricating oils and grease resistant - High mechanical strength - Excellent flame retardant properties - Excellent mechanical & electrical properties Standard Packing Coils 100, 200, 500 and 1000m Conductor Flexible Bare Copper Wire Insulation Pvc Insulation Cables Type FLRY-A and FLRY-B Color Blue, Black, Brown, Grey, Orange, Pink, Red, Violet, White, Green, Yellow, Yellow / Green, Lining Strip Color Also and as per Customer Requirement Temperature 20�?�°c to 105�?�°c Application These cables are used as original equipment's for wiring automobiles and in the auto harnesses
Cable Standard SAE J1127 VDE 0295, IEC 60228, IS 2465, BS 6862 Cable Features - Excellent flexibility - The NESKEB Auto cables is impervious to water, petrol, diesel, acids, engine and lubricating oils and grease resistant - High mechanical strength - Excellent flame retardant properties - Excellent mechanical & electrical properties - Special heat resistant insulation - Minimum bending radius Standard Packing Coils 25, 50, 100, 200 And 500m. Conductor Flexible Battery Cables: Flexible bare copper class 5 conductors to IEC 60228 Extra Flexible Battery Cables: Flexible bare copper class 6 conductors to IEC 60228 Insulation Flexible Battery Cables: HR PVC Extra Flexible Battery Cables: HOFR(TPR Rubber) Separator Polyester tape over conductor for HOFR insulated extra flexible battery cables Color : Red, Black Application These wires used low voltage circuit in automobiles such a Vehicles and Motor cycles. Where high flexibility is required.
Cable Features - Special heat resistant insulation - Higher current carrying capacity. - Fine copper wires - Highly thermal stable insulation - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Cable Standard IS : 694 : 2010 & BS 6004, BS EN 50525-2-31 Application Fixed installation in conduits and under plaster, for appliance wiring and distribution stations. Standard Packing Coils 90 and 180m Conductor Flexible Bare Copper conductor class-2 and class-5 as per IS: 8130 EN 60228 Insulation HR/FR/FRLS-H/ZHFR Insulation compound with a high insulation resistance value as per IS:5831 Color Red, Yellow/green, Blue, Black, Brown, Grey, Orange, White, Green, Yellow Properties PVC Self-extinguishing and flame retardant according to EN 60332-1-2
Cable Standard Generally conforms to IS 694:2010, IEC60228, BS 6004 Silent Features - Special heat resistant insulation - Higher current carrying capacity - Fine copper wires - Highly thermal stable insulation - High electrical conductivity - Long Life - Excellent mechanical & electrical properties Technical Data Operating Temp : -10�?�°C to max.+90�?�°C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Standard Packing Coils 100, 200, 500 and 1000m. Conductor Bare Copper class1 or class-2 as per IS:8130, IEC 60228 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Black, Green, Yellow/green or as per customer requirement Application Neskeb - Earth : Installation in surface mounted or embedded conduits, or similar closed systems
Cable Standard Generally conforms to DIN VDE 0281-5&2, BS:6500, EN-50525-2-11, IEC 60227-5 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistance to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -5C to 70C Operating Temp : 20c to +80C Nominal Voltage : 300/500 V Test Voltage : 2000V Min. Bending Radius : 6x Cable Diameter Standard Packing Coils 100, 200, 500 and 1000m Conductor Annealed flexible bare Copper (Class 5 - Flexible Plain Copper) according to VDE 0295 IEC 60228. Insulation PVC T12 to according to EN 50363-3, BS 7655 Sheath PVC TM2.to according to EN 50363-3, BS 7655 Color White, Black, Blue or as per customer order Core Identification 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/green, Brown, Black, Grey 5 Core - Yellow/green, Blue, Brown, Black and Grey Application H05VV-F cordage is a flexible PVC insulated, PVC jacketed harmonized cord recommended for use in electronic and electrical equipment such as office.
Silent Features (FR and FRLS) - Good Flame Retardant Properties - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties - Steam and boiling water resistant Silent Features (ZHFR) - Zero Halogen acid gas Evolution - Non-corrosive and non-toxic insulation - High-temperature resistant insulation - Better Flame retardant property - Excellent resistance to moisture, abrasion, grace, oil - Long Life Technical Data Operating Temp : -10Cto max.+90C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Flame propagation : Flame retardant test as per IS 10810-58,64, IEC 60332-1 Standard Packing Coils 90m, 180m and 360m Conductor Annealed flexible bare Copper class-2 and class-5 Conductor as per IS:8130-1984 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Red, yellow, Blue, Black, Brown, Grey, Orange, White, Green, Yellow/green or as per customer requirement Application Fixed installation in conduits and under plaster, for appliance wiring & distribution stations. Fixed Wiring in Conduits & Building wire Application
Cable Standard IS 694:2010, BS 6500 Silent Features - High Flexibility - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m. Conductor Flexible Bare or Tinned Bunch Copper as per IS:8130-1984 Insulation PVC as per IS:5831-1984 Sheath PVC as per IS:5831-1984 Core Color As per IS 694 : 2010 2 Core â?? Red & Black 3 Core â?? Red, Black, Green or Red, Yellow and Blue 4 Core - Red, Yellow, Blue and Green or Black Application Ideal For industrial induction motor, power tools, electrical machinery etc.
Cable Standard Generally conforms to EN-50525-2-21, DIN VDE 0282 part 810,IEC 245 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistant to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -25�?�°C to 70�?�°C Operating Temp : -20�?�°C to max. +90�?�°C Nominal Voltage : 450/750 V Test Voltage : 2500V Min. Bending Radius : 6 x cable Diameter Flame propagation : Flame retardant test as per IEC 60332-1-2 Standard Packing Coils 100, 200,500 and 1000m Conductor Flexible bare Class 5 copper conductor according to DIN VDE 0295,IEC 60228 Insulation Rubber Type El-4 to VDE 0282 Part-1 Sheath Neoprene Jacket Rubber Type EM-2 Color White, Black, Blue or as per customer order Core Identification 1 Core - Black 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/Green, Brown, Black, Grey 5 Core - Yellow/Green, Blue, Brown, Black and Grey Application H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites
Cable Standard IS 694:2010, BS 6500, IEC 60227 Silent Features - Excellent flexibility - Excellent resistant to moisture, abrasion, grease, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130 Insulation PVC As Per IS:5831 Outer Sheath PVC As Per IS:5831 Core Color As per IS: 694:2010 â?? 3C - Red, Yellow, Blue, 4C - Red, Yellow, Blue, Black As per IEC:60227 - 3C - Black, Blue, Brown. 4C - Black, Blue, Brown, Green or Yellow/Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply
Cable Standard DIN VDE 0282 part 810, IEC 245 & BS 6007, BS 6899 Silent Features - Temperature range -40�° to +90�° - Exceptional long term performance - Excellent Impact Resistant - Excellent Weather Resistant Technical Data Operating Temp : -20�°c to Max.+90�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130, IEC 60228 Insulation EPR Rubber Outer Sheath EPR Rubber Core Color 3C - Red, Yellow, Blue, Or Black, Blue, Brown 4C- Red, Yellow, Blue, Black Or Black, Blue, Brown, Green or Yellow/Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply.
Cable Standard Generally conforms to, Based on IS:9857-1990 VDE 0282, IEC 245-6, BS 6899 Silent Features - Ultra high performance flexible welding lead, double insulated for longer life and added safety - Better flame retardant properties - Outstanding toughness & durability - High resistance to cuts, tears & abrasion - Resistance to oil, solvents and chemicals - Excellent ozone and weather resistant Technical Data Fixed Installation : -20C to max.+90C Nominal Voltage : 600 V Spark Test : 3.5 KV(ac) Color : Orange / Black Jacket Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 and 500m Conductor High conductivity, bare annealed copper flexible conductor, EC copper class 5 & class 6 generally conforms to IS:8130-1984, IEC 60228 Separation Polyester tape Insulation Double Insulated/single insulated flexible Nitrile rubber HOFR insulated as per IS:6380-1984 Color Orange / Black Jacket Current Rating The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25 C and a maximum conductor temperature of 90 C. The percentage duly cycles for various processes and applications are as follows: - Automobile Welding : up to 100% - Semi Automatic Welding : 30% to 85% - Manual Welding : 0% to 60% - Very intermittent or Occasional Welding : up to 20% Voltage Drop When total cable lengths in excess of 15mtr., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive & welding currents are maintained at adequate levels. Application Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Electrical Characteristics - Rated Voltage : 0.6/1 kV AC - Rated DC Voltage : 1.5 kV - Maximum Permitted DC Voltage : 1.8 kV (conductor/conductor, non earthen system, circuit not under load) - Maximum Permitted AC Voltage : 1 KV - Working Voltage : DC 1000 V - Spark Test : 6000 V. ac (8400 Vdc) - Voltage Withstand : 6500 V as per EN50395 for 5 min - Ampacity : According to requirements for cables for PV systems Technical Data - Ambient Temperature : -40C +90C - Minimum Bending Radius : 5 x OD (fixed), 15 x OD (occasional flexing) - Flame retardant according to IEC 60332-1-2 - Low smoke emission < 20% as per ASTM D-2843 - Halogen free according to EN 50267-2-1/-2, IEC 60754-2 - Maximum Temperature at Conductor : 120C (20000h) - Short Circuit Temperature : 200�?�°C (at conductor max. 5sec) - Thermal Endurance Test : According to EN 60216-2 (temperature index +120C) - High Temperature Pressure : Test according to EN 60811-3-1 - Excellent mechanical and electrical properties. - UV resistance & OZONE resistance - Flexibility & suitability for fast & easy installation Cable Standard EN 50618 Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Electrolytic fine Tinned copper class-5 conductor according to IEC 60228 Insulation XLPO (Crosslinked Halogen Free & Flame Retardant) Sheath XLPO (Crosslinked Halogen Free & Flame Retardant) Color Red, Black and also available black color with red lining. Application For Solar Panel, Solar Power Plant, Solar Pump Installation.
Cable Standard BS:5308 (172) IEC 189 (1&2) Silent Features - Wear & Tear Resistance - Long Life - Easy to Cable Slitting - Fire Resistance Technical Data Working Temp : 70C / 90C / 105C as per Insulation Nominal Voltage : 300/500 V Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application Standard Packing Coils 100, 200, 500 & 1000m Conductor Annealed Plain Bare Copper or Tinned Copper As per IEC 60228 Insulation PVC/ XLPE/ PE/ LSZH/ EPR Sheath PVC/ Rubber/ LSZH/ FRLS Type Armoured or Unarmoured. Elements Insulated core/Pairs / Tried / Quads Color / multi core cable number marking on core Shield Aluminum mylar tape screen with tinned copper drain wire individual shielding or Overall Shielding Braiding Tinned copper braiding as per requirement Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application
Product Specification : PVC SUBMERSIBLE CABLE , SEALDED , DOUBLE SEALDED . Core Material PVC Size 2.5, 4, and 6 mm Cable Shape : ROUND, Flat Core Type 3 Core, 4 CORE , 5 CORE UP TO 10 CORE Power Rating 1100V
Abbott BMW Guide Wire with hi-torque balance middleweight universal guide wire is a front-line guide wire offering a unique balance of support and flexibility, with enhancements in the areas of device compatibility, distal access, deliverability in tortuous anatomy and tip durability. INDICATIONS FOR USE This HI-TORQUE Guide Wire is intended to facilitate the placement of balloon dilatation catheters during Percutaneous Transluminal Coronary Angioplasty (PTCA) and Percutaneous Transluminal Angioplasty (PTA). This guide wire may also be used with compatible stent devices during therapeutic procedures. CONTRAINDICATIONS Not intended for use in the cerebral vasculature or with atherectomy devices. WARNINGS This device is designed and intended for ONE-TIME USE ONLY. Do not resterilize and / or reuse. Carefully observe the instructions under Do Not and Do below. Failure to do so may result in vessel trauma, guide wire damage, guide wire tip separation, or stent damage. If resistance is observed at any time, determine the cause under fluoroscopy and take remedial action as needed. Use the most suitable guide wire for the lesion being treated.
Guide wires with a high manoeuvrability in the chronic occluded lesion, and a tip designed to improve penetrability into the lesion while remaining flexible. Features 0.014" Guide wire Tapered tip options, 0.010" (1.7gf wire), 0.011" (3.5gf wire) and 0.012" (4.5gf wire) 1.7gf, 3.5gf and 4.5gf Tip load options 1:1 Torque 40cm Hydrophilc coating 15cm Spring coil length 15cm Radiopaque segment Available in 190cm and 300cm lengths