Cable Standard
Generally conforms to EN-50525-2-21,
DIN VDE 0282 part 810,IEC 245
Cable Features
- Special heat resistant insulation
- High current carrying capacity
- Less heat energy radiation
- Longer life
- High compatibility of cores
- Excellent resistant to moisture, abrasion,
grace, oil
- Excellent mechanical & electrical properties
- Insulation is highly thermal stable
- Harmonized acc. to European standards
Technical Data
Working Temp : -25�?�°C to 70�?�°C
Operating Temp : -20�?�°C to max. +90�?�°C
Nominal Voltage : 450/750 V
Test Voltage : 2500V
Min. Bending Radius : 6 x cable Diameter
Flame propagation : Flame retardant test
as per IEC 60332-1-2
Standard Packing
Coils 100, 200,500 and 1000m
Conductor
Flexible bare Class 5 copper
conductor according to
DIN VDE 0295,IEC 60228
Insulation
Rubber Type El-4 to
VDE 0282 Part-1
Sheath
Neoprene Jacket Rubber
Type EM-2
Color
White, Black, Blue or
as per customer order
Core Identification
1 Core - Black
2 Core - Blue & Brown
3 Core - Yellow/green, Blue, Brown
4 Core - Yellow/green, Blue, Brown, Black or
Yellow/Green, Brown, Black, Grey
5 Core - Yellow/Green, Blue, Brown, Black and Grey
Application
H07RN-F rubber insulated and sheathed cables
are intended for flexible connection to electrical
equipment. They are suitable for both indoor and
outdoor use in industrial and agricultural plant
and on construction sites
Silent Features
- Excellent flexibility
- Excellent resistant to moisture, abrasion,
grease, oil
- Long Life
- Excellent mechanical & electrical properties
Technical Data
Working Temp : Max.+70�°C
Nominal Voltage : 1.1 KV
Test Voltage : 3.0 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130
Insulation
PVC As Per IS:5831
Outer Sheath
PVC As Per IS:5831
Core Color
As per IS: 694:2010 â?? 3C - Red, Yellow, Blue, 4C -
Red, Yellow, Blue, Black
As per IEC:60227 - 3C - Black, Blue, Brown.
4C - Black, Blue, Brown, Green or Yellow/Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply
Pumps, Submersible Pump Motor Power Supply
Cable Standard
Generally conforms to, Based on IS:9857-1990 VDE 0282,
IEC 245-6, BS 6899
Silent Features
- Ultra high performance flexible welding lead, double insulated
for longer life and added safety
- Better flame retardant properties
- Outstanding toughness & durability
- High resistance to cuts, tears & abrasion
- Resistance to oil, solvents and chemicals
- Excellent ozone and weather resistant
Technical Data
Fixed Installation : -20C to max.+90C
Nominal Voltage : 600 V
Spark Test : 3.5 KV(ac)
Color : Orange / Black Jacket
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200, 300 and 500m
Conductor
High conductivity, bare annealed copper flexible
conductor, EC copper class 5 & class 6 generally
conforms to IS:8130-1984, IEC 60228
Separation
Polyester tape
Insulation
Double Insulated/single insulated flexible Nitrile
rubber HOFR insulated as per IS:6380-1984
Color
Orange / Black Jacket
Current Rating
The maximum current ratings of flexible welding cables for different
duly cycles are based on an ambient air temperature of 25 C and a
maximum conductor temperature of 90 C. The percentage duly cycles
for various processes and applications are as follows:
- Automobile Welding : up to 100%
- Semi Automatic Welding : 30% to 85%
- Manual Welding : 0% to 60%
- Very intermittent or Occasional Welding : up to 20%
Voltage Drop
When total cable lengths in excess of 15mtr., are involved, it may be necessary
to use cables of larger cross section to ensure that the voltage drop is not
excessive & welding currents are maintained at adequate levels.
Application
Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use
under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Electrical Characteristics
- Rated Voltage : 0.6/1 kV AC
- Rated DC Voltage : 1.5 kV
- Maximum Permitted DC Voltage : 1.8 kV (conductor/conductor,
non earthen system, circuit not under load)
- Maximum Permitted AC Voltage : 1 KV
- Working Voltage : DC 1000 V
- Spark Test : 6000 V. ac (8400 Vdc)
- Voltage Withstand : 6500 V as per EN50395 for 5 min
- Ampacity : According to requirements for cables for PV systems
Technical Data
- Ambient Temperature : -40C +90C
- Minimum Bending Radius : 5 x OD (fixed), 15 x OD
(occasional flexing)
- Flame retardant according to IEC 60332-1-2
- Low smoke emission < 20% as per ASTM D-2843
- Halogen free according to EN 50267-2-1/-2, IEC 60754-2
- Maximum Temperature at Conductor : 120C (20000h)
- Short Circuit Temperature : 200�?�°C (at conductor max. 5sec)
- Thermal Endurance Test : According to EN 60216-2
(temperature index +120C)
- High Temperature Pressure : Test according to EN 60811-3-1
- Excellent mechanical and electrical properties.
- UV resistance & OZONE resistance
- Flexibility & suitability for fast & easy installation
Cable Standard
EN 50618
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Electrolytic fine Tinned
copper class-5 conductor according
to IEC 60228
Silent Features
- High flexibility
- Excellent resistant to moisture, abrasion,
grease, oil
- Long Life
- Excellent mechanical & electrical properties
Technical Data
Working Temp : Max.+70�°C
Nominal Voltage : 1.1 KV
Test Voltage : 3.0 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200, 300 , 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130
Insulation
PVC As Per IS:5831
Inner Sheath
PVC
Outer Sheath
PVC As Per IS:5831
Core Color
As per IEC 60227 3C -Blue, Brown, Black or Yellow/
Green, 4C -Blue, Brown, Black, Grey or Yellow/Green
As per IS 694 : 2010 - 3C - Red, Yellow and Blue
4C - Red, Yellow, Blue and Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply
Pumps, Submersible Pump Motor Power Supply.
Cable Standard
DIN VDE 0282 PART 810, IEC 245 & BS 6007,
BS 6899
Silent Features
- Temperature range -40�° to +90�°
- Excellent Impact Resistant
- Excellent Weather Resistant
Technical Data
Operating Temp : Temp. range -40 to +90
Nominal Voltage : 1.1 KV
Test Voltage : 2.5 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130, IEC 60228
Insulation
EPR Rubber as per IS:6380,
VDE 0282 (Part-1)
Inner Sheath
NBR/TPR Rubber as per IS:6380,
VDE 0282 (Part-1)
Outer Sheath : NBR/TPR Rubber as per IS:6380,
VDE 0282 (Part-1)
Core Color
As per IEC 60227 3C - Blue, Brown, Black or Yellow/
green, 4C - Blue, Brown, Black, Grey or Yellow/green
As per IS 694 : 2010 -3C - Red, Yellow and Blue
4C - Red, Yellow, Blue and Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply Pumps & Submersible Motor Power Supply.
Cable Standard
According to DIN 72551-6 & ISO 6722 B
JIS C 3406, JASO D 611/608, IS 2465,
BS 6862 : PART 1
Cable Features
- Excellent flexibility
- The NESKEB Auto cables is impervious
to water, petrol, diesel, acids, engine and
lubricating oils and grease resistant
- High mechanical strength
- Excellent flame retardant properties
- Excellent mechanical & electrical properties
Standard Packing
Coils 100, 200, 500 and 1000m
Conductor
Flexible Bare Copper Wire
Insulation
Pvc Insulation
Cables Type
FLRY-A and FLRY-B
Color
Blue, Black, Brown, Grey, Orange,
Pink, Red, Violet, White, Green,
Yellow, Yellow / Green, Lining Strip
Color Also and as per Customer
Requirement
Temperature
20�?�°c to 105�?�°c
Application
These cables are used as original equipment's
for wiring automobiles and in the auto harnesses
Cable Standard
SAE J1127 VDE 0295, IEC 60228,
IS 2465, BS 6862
Cable Features
- Excellent flexibility
- The NESKEB Auto cables is impervious
to water, petrol, diesel, acids, engine and
lubricating oils and grease resistant
- High mechanical strength
- Excellent flame retardant properties
- Excellent mechanical & electrical properties
- Special heat resistant insulation
- Minimum bending radius
Standard Packing
Coils 25, 50, 100, 200 And 500m.
Conductor
Flexible Battery Cables: Flexible bare copper class 5 conductors to IEC 60228
Extra Flexible Battery Cables: Flexible bare copper class 6 conductors to IEC 60228
Cable Features - Special heat resistant insulation - Higher current carrying capacity. - Fine copper wires - Highly thermal stable insulation - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Cable Standard IS : 694 : 2010 & BS 6004, BS EN 50525-2-31 Application Fixed installation in conduits and under plaster, for appliance wiring and distribution stations. Standard Packing Coils 90 and 180m Conductor Flexible Bare Copper conductor class-2 and class-5 as per IS: 8130 EN 60228 Insulation HR/FR/FRLS-H/ZHFR Insulation compound with a high insulation resistance value as per IS:5831 Color Red, Yellow/green, Blue, Black, Brown, Grey, Orange, White, Green, Yellow Properties PVC Self-extinguishing and flame retardant according to EN 60332-1-2
Cable Standard
Generally conforms to IS 694:2010, IEC60228, BS 6004
Silent Features
- Special heat resistant insulation
- Higher current carrying capacity
- Fine copper wires
- Highly thermal stable insulation
- High electrical conductivity
- Long Life
- Excellent mechanical & electrical properties
Technical Data
Operating Temp : -10�?�°C to max.+90�?�°C
Nominal voltage : 1.1 KV
Test voltage : 3.0 KV
Standard Packing
Coils 100, 200, 500 and 1000m.
Conductor
Bare Copper class1 or class-2 as per IS:8130,
IEC 60228
Insulation
PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984
Color
Black, Green, Yellow/green or as per customer requirement
Application
Neskeb - Earth : Installation in surface mounted or embedded
conduits, or similar closed systems
Cable Standard
Generally conforms to DIN VDE 0281-5&2,
BS:6500, EN-50525-2-11, IEC 60227-5
Cable Features
- Special heat resistant insulation
- High current carrying capacity
- Less heat energy radiation
- Longer life
- High compatibility of cores
- Excellent resistance to moisture, abrasion,
grace, oil
- Excellent mechanical & electrical properties
- Insulation is highly thermal stable
- Harmonized acc. to European standards
Technical Data
Working Temp : -5C to 70C
Operating Temp : 20c to +80C
Nominal Voltage : 300/500 V
Test Voltage : 2000V
Min. Bending Radius : 6x Cable Diameter
Standard Packing
Coils 100, 200, 500 and 1000m
Conductor
Annealed flexible bare Copper
(Class 5 - Flexible Plain Copper)
according to VDE 0295 IEC 60228.
Insulation
PVC T12 to according to
EN 50363-3, BS 7655
Sheath
PVC TM2.to according to
EN 50363-3, BS 7655
Color
White, Black, Blue or
as per customer order
Core Identification
2 Core - Blue & Brown
3 Core - Yellow/green, Blue, Brown
4 Core - Yellow/green, Blue, Brown, Black or
Yellow/green, Brown, Black, Grey
5 Core - Yellow/green, Blue, Brown, Black and Grey
Application
H05VV-F cordage is a flexible PVC insulated, PVC
jacketed harmonized cord recommended for use in
electronic and electrical equipment such as office.
Abbott BMW Guide Wire with hi-torque balance middleweight universal guide wire is a front-line guide wire offering a unique balance of support and flexibility, with enhancements in the areas of device compatibility, distal access, deliverability in tortuous anatomy and tip durability.
INDICATIONS FOR USE
This HI-TORQUE Guide Wire is intended to facilitate the placement of balloon dilatation catheters during Percutaneous Transluminal Coronary Angioplasty (PTCA) and Percutaneous Transluminal Angioplasty (PTA). This guide wire may also be used with compatible stent devices during therapeutic procedures.
CONTRAINDICATIONS
Not intended for use in the cerebral vasculature or with atherectomy devices.
WARNINGS
This device is designed and intended for ONE-TIME USE ONLY. Do not resterilize and / or reuse.
Carefully observe the instructions under Do Not and Do below. Failure to do so may result in vessel trauma, guide wire damage, guide wire tip separation, or stent damage. If resistance is observed at any time, determine the cause under fluoroscopy and take remedial action as needed. Use the most suitable guide wire for the lesion being treated.
Guide wires with a high manoeuvrability in the chronic occluded lesion, and a tip designed to improve penetrability into the lesion while remaining flexible.
Features
0.014" Guide wire
Tapered tip options, 0.010" (1.7gf wire), 0.011" (3.5gf wire) and 0.012" (4.5gf wire)
1.7gf, 3.5gf and 4.5gf Tip load options
1:1 Torque
40cm Hydrophilc coating
15cm Spring coil length
15cm Radiopaque segment
Available in 190cm and 300cm lengths
Material - Stainless Steel
Length - 2.5 m
Country of Origin - Made in India
Finished - Hot Dip Galvanized
Thickness - 1.5 mm
Width - 300mm
These Stainless Steel Cable Covers are extensively used with cable trays for providing mechanical and environmental protection for cables and other items. These covers can be installed as either closed or ventilated, depending on the requirements. Available in different dimensions to suit specific type of cable trays, these covers are wisely made of best quality stainless steel.
These are available as flat, peaked and peaked & vented covers. Wisely made from sheet steel, these covers provide excellent protection to cables from outside harsh environment elements. We sternly test these covers on various standard quality parameters prior to final dispatch in the industry.