All type of lead acid battery for UPS, inverter and automotive.
Battery scrap, lead acid battery.Manufacturing
Batteries.
Automative battery, tubular battery, and battery plates..
Car Battery, Automotive Battery, Deep Cycle 2v Cell Battery, Tubular Battery, Solar Battery.
Battery for inverter & new tyres for truck & cars.
Sodium silicate, alkaline, neutral grades.
Battery terminals, roof lights for trucks and buses, auto electronic products.Manufactaring, transportion, shipping
Motorcycle Batteries, Automotive Batteries, E Rickshaw Batteries, Tubular Inverter Batteries, Solar Batteries.
Portable metal hardness tester, surface roughness tester, metallurgical microscope and all types of metallurgical laboratory equipment.
Cable Standard SAE J1127 VDE 0295, IEC 60228, IS 2465, BS 6862 Cable Features - Excellent flexibility - The NESKEB Auto cables is impervious to water, petrol, diesel, acids, engine and lubricating oils and grease resistant - High mechanical strength - Excellent flame retardant properties - Excellent mechanical & electrical properties - Special heat resistant insulation - Minimum bending radius Standard Packing Coils 25, 50, 100, 200 And 500m. Conductor Flexible Battery Cables: Flexible bare copper class 5 conductors to IEC 60228 Extra Flexible Battery Cables: Flexible bare copper class 6 conductors to IEC 60228 Insulation Flexible Battery Cables: HR PVC Extra Flexible Battery Cables: HOFR(TPR Rubber) Separator Polyester tape over conductor for HOFR insulated extra flexible battery cables Color : Red, Black Application These wires used low voltage circuit in automobiles such a Vehicles and Motor cycles. Where high flexibility is required.
Submersible pump cables, welding cables, battery cables, auto cables, solar cables, borehole cables, bore well pump cables, dewatering punp cables, sewage pump cables, copper flexible cables, h07rn f cables, h05vv f cables, rubber submersible pump cables, house wires, building wires, h07v k, h05v k, marine control cables, control cables, instrumentation cables, earthing cables, power cables and many more flat cables and round cables.Transportation
Hair shampoo, hair oils, washing powders, washing liquids, home cleaning products, incense sticks, biscuits, dry fruits, chocolates, spices, detergent cakes, detergent powders, vessels liquids, vessels Powders, hair colours, shaving creams, tea, camphors, razors, battery cells..Transportation, Returning of product if its defective, Giving the superior quality of goods
Silent Features (FR and FRLS) - Good Flame Retardant Properties - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties - Steam and boiling water resistant Silent Features (ZHFR) - Zero Halogen acid gas Evolution - Non-corrosive and non-toxic insulation - High-temperature resistant insulation - Better Flame retardant property - Excellent resistance to moisture, abrasion, grace, oil - Long Life Technical Data Operating Temp : -10Cto max.+90C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Flame propagation : Flame retardant test as per IS 10810-58,64, IEC 60332-1 Standard Packing Coils 90m, 180m and 360m Conductor Annealed flexible bare Copper class-2 and class-5 Conductor as per IS:8130-1984 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Red, yellow, Blue, Black, Brown, Grey, Orange, White, Green, Yellow/green or as per customer requirement Application Fixed installation in conduits and under plaster, for appliance wiring & distribution stations. Fixed Wiring in Conduits & Building wire Application
Cable Standard IS 694:2010, BS 6500 Silent Features - High Flexibility - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m. Conductor Flexible Bare or Tinned Bunch Copper as per IS:8130-1984 Insulation PVC as per IS:5831-1984 Sheath PVC as per IS:5831-1984 Core Color As per IS 694 : 2010 2 Core â?? Red & Black 3 Core â?? Red, Black, Green or Red, Yellow and Blue 4 Core - Red, Yellow, Blue and Green or Black Application Ideal For industrial induction motor, power tools, electrical machinery etc.
Cable Standard Generally conforms to EN-50525-2-21, DIN VDE 0282 part 810,IEC 245 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistant to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -25�?�°C to 70�?�°C Operating Temp : -20�?�°C to max. +90�?�°C Nominal Voltage : 450/750 V Test Voltage : 2500V Min. Bending Radius : 6 x cable Diameter Flame propagation : Flame retardant test as per IEC 60332-1-2 Standard Packing Coils 100, 200,500 and 1000m Conductor Flexible bare Class 5 copper conductor according to DIN VDE 0295,IEC 60228 Insulation Rubber Type El-4 to VDE 0282 Part-1 Sheath Neoprene Jacket Rubber Type EM-2 Color White, Black, Blue or as per customer order Core Identification 1 Core - Black 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/Green, Brown, Black, Grey 5 Core - Yellow/Green, Blue, Brown, Black and Grey Application H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites
Cable Standard IS 694:2010, BS 6500, IEC 60227 Silent Features - Excellent flexibility - Excellent resistant to moisture, abrasion, grease, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130 Insulation PVC As Per IS:5831 Outer Sheath PVC As Per IS:5831 Core Color As per IS: 694:2010 â?? 3C - Red, Yellow, Blue, 4C - Red, Yellow, Blue, Black As per IEC:60227 - 3C - Black, Blue, Brown. 4C - Black, Blue, Brown, Green or Yellow/Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply
Cable Standard DIN VDE 0282 part 810, IEC 245 & BS 6007, BS 6899 Silent Features - Temperature range -40�° to +90�° - Exceptional long term performance - Excellent Impact Resistant - Excellent Weather Resistant Technical Data Operating Temp : -20�°c to Max.+90�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130, IEC 60228 Insulation EPR Rubber Outer Sheath EPR Rubber Core Color 3C - Red, Yellow, Blue, Or Black, Blue, Brown 4C- Red, Yellow, Blue, Black Or Black, Blue, Brown, Green or Yellow/Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply.
Cable Standard Generally conforms to, Based on IS:9857-1990 VDE 0282, IEC 245-6, BS 6899 Silent Features - Ultra high performance flexible welding lead, double insulated for longer life and added safety - Better flame retardant properties - Outstanding toughness & durability - High resistance to cuts, tears & abrasion - Resistance to oil, solvents and chemicals - Excellent ozone and weather resistant Technical Data Fixed Installation : -20C to max.+90C Nominal Voltage : 600 V Spark Test : 3.5 KV(ac) Color : Orange / Black Jacket Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 and 500m Conductor High conductivity, bare annealed copper flexible conductor, EC copper class 5 & class 6 generally conforms to IS:8130-1984, IEC 60228 Separation Polyester tape Insulation Double Insulated/single insulated flexible Nitrile rubber HOFR insulated as per IS:6380-1984 Color Orange / Black Jacket Current Rating The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25 C and a maximum conductor temperature of 90 C. The percentage duly cycles for various processes and applications are as follows: - Automobile Welding : up to 100% - Semi Automatic Welding : 30% to 85% - Manual Welding : 0% to 60% - Very intermittent or Occasional Welding : up to 20% Voltage Drop When total cable lengths in excess of 15mtr., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive & welding currents are maintained at adequate levels. Application Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Electrical Characteristics - Rated Voltage : 0.6/1 kV AC - Rated DC Voltage : 1.5 kV - Maximum Permitted DC Voltage : 1.8 kV (conductor/conductor, non earthen system, circuit not under load) - Maximum Permitted AC Voltage : 1 KV - Working Voltage : DC 1000 V - Spark Test : 6000 V. ac (8400 Vdc) - Voltage Withstand : 6500 V as per EN50395 for 5 min - Ampacity : According to requirements for cables for PV systems Technical Data - Ambient Temperature : -40C +90C - Minimum Bending Radius : 5 x OD (fixed), 15 x OD (occasional flexing) - Flame retardant according to IEC 60332-1-2 - Low smoke emission < 20% as per ASTM D-2843 - Halogen free according to EN 50267-2-1/-2, IEC 60754-2 - Maximum Temperature at Conductor : 120C (20000h) - Short Circuit Temperature : 200�?�°C (at conductor max. 5sec) - Thermal Endurance Test : According to EN 60216-2 (temperature index +120C) - High Temperature Pressure : Test according to EN 60811-3-1 - Excellent mechanical and electrical properties. - UV resistance & OZONE resistance - Flexibility & suitability for fast & easy installation Cable Standard EN 50618 Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Electrolytic fine Tinned copper class-5 conductor according to IEC 60228 Insulation XLPO (Crosslinked Halogen Free & Flame Retardant) Sheath XLPO (Crosslinked Halogen Free & Flame Retardant) Color Red, Black and also available black color with red lining. Application For Solar Panel, Solar Power Plant, Solar Pump Installation.