Cable float switch.
Mode filter, power choke inductor, inductor transformers.Manufacturers
Voltage Monitoring Series SM 501 86 Cat. No. Parameters MG53BH MG53BF MG63BH MG63BF 415 VAC (3 Phase, 3 Wire) 220 VAC (3 Phase, 3 Wire) Frequency Power Consumption (Max.) 10 VA 5 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) Trip Settings Under Voltage Over Voltage Hysterisis 7 V (�± 2 V) of Trip Voltage Phase Loss Phase Sequence Phase Asymmetry Yes Yes LED Indication Storage Temperature Operating Temperature Separate indications for Power ON, UV and OV; ON: Phase Reverse; BLINK: Phase Asymmetry O -15 C To + 55 C O O -25 C To + 70 C O Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 2 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale 2) In the event of Phase Sequence or Phase Loss, OFF Delay is 100 ms Humidity (Non Condensing) 95% (Rh) 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) Time 5 s Delay ON Delay Trip Time (OFF Delay) 10% (of ) Cat. No. Description MG53BH 415 VAC, & Single Phasing Preventor (SPP) with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG53BF 415 VAC, UV / OV & SPP with Selectable OFF Delay (0.5 to 15 sec), 2 C/O MG63BH 220 VAC, with Selectable ON Delay (0.5 to 15 sec), 2 C/O MG63BF 220 VAC, with Selectable OFF Delay (0.5 to 15 sec), 2 C/O UV / OV UV / OV & SPP UV / OV & SPP EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level III Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class B Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms RoHS Compliant LED Indications for Power and Fault conditions Voltage Sensing Principle 2 C/O Configuration
Protects against Phase Loss, Phase Reversal & Phase Asymmetry Can be configured for 3 Phase 4 Wire or 1 Phase system Selectable Over Voltage / Under Voltage Trip level Selectable Time Delay LED Indications for Power and Fault conditions Voltage Sensing principle 1 C/O or 2 C/O Configuration Voltage Monitoring Series SM 500 83 Cat. No. Parameters 240 VAC (1 Phase & 3 Phase, 4 Wire) Frequency Power Consumption (Max.) 4 VA 50/60 Hz Supply Voltage ( ) 105% to 125% (of ) 55% to 95% (of ) LED Indication Operating Temperature Storage Temperature Separate indications for Power ON, UV and OV O O -15 C To + 55 C O O -25 C To + 70 C Utilization Category AC - 15 DC - 13 Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A Trip Settings Under Voltage Phase Loss Phase Sequence Phase Asymmetry Over Voltage 0.5 to 15 s (Selectable) 5 s 0.5 to 15 s (Selectable) 5 s 5 s 0.5 s to 15 min (Selectable) Time Delay ON Delay Trip Time (OFF Delay) Output Contact Rating Electrical Life Mechanical Life Relay Output 5A @ 250 VAC / 28 VDC (Resistive) 5 1X10 6 3X10 1 C/O Enclosure Dimension (W x H x D) (in mm) Weight (unpacked) Approx. Mounting Certification Flame Retardant UL 94-V0 36 X 90 X 60 120 g Base / DIN rail Degree of Protection IP 20 for Terminals, IP 40 for Enclosure ORDERING INFORMATION Note: 1) Voltage setting is with respect to Neutral. Voltage Setting Accuracy: �± 5 % of Full Scale; Time Setting Accuracy: �± 10 % of Full Scale RoHS Compliant Humidity (Non Condensing) 95% (Rh) EMI / EMC Harmonic Current Emissions IEC 61000-3-2 Ed. 3.2 (2009-04) Class A ESD IEC 61000-4-2 Ed. 2.0 (2008-12) Level II Radiated Susceptibility IEC 61000-4-3 Ed. 3.2 (2010-04) Level III Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV Conducted Susceptibility IEC 61000-4-6 Ed. 3.0 (2008-10) Level III Voltage Dips & Interruptions (AC) IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A Environmental Cold Heat IEC 60068-2-1 Ed. 6.0 (2007-03) Dry Heat IEC 60068-2-2 Ed. 5.0 (2007-07) Vibration IEC 60068-2-6 Ed. 7.0 (2007-12) 5g Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms Non-Repetitive Shock IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms Cat. No. Description MD71BH 240 VAC, UV / OV with Selectable ON Delay (0.5 to 15 sec), 1 C/O MD71BF 240 VAC, UV / OV with Selectable OFF Delay (0.5 to 15 sec), 1 C/O MD71B9 240 VAC, UV / OV with Selectable ON Delay (0.5 s to 15 min), 1 C/O
CONTINUOUS PASSIVE MOTION unit is designed for lower limb. It is based on solid-state circuitry, silent, smooth & powerful servo motor for continuous operation, instant start/stop. APPLICATION Continuous Passive Motion Therapy immediately used after surgery can give several important benefits to patient like maintenance or improvement in the range of motion reduction in pain and discomfort.
We have all type of sumitomo coupler & terminals .
All the type of such as makita, dewalt, aeg As per request
All types of automotive electrical switches/ and new generation sensors. All types of truck heavy commercial vendor OEM spareparts..
Servicing Of Lt And Ht Breaker Seals & Servicing All Electrical Equipment..
Electrical terminal, PVC channel cable duct, reverse forward switches.
1/2.8 HD Image sensor 2.4 MP HD Resolution 4 IN 1 / AHD/CVI/TVI/ANALOG Support 500 Mtr Co-axial Transmittion 18 Smart IR LED 3.6mm fixed lens(6mm optional) 4in1 Video Mode Change by UTC Control Day / Night True Vision ABS PVC Material [FCC,CE,RoHS,GMP Certified]
1/2.8 HD Image sensor 2.4 MP HD Resolution 4 IN 1 / AHD/CVI/TVI/ANALOG Support 500 Mtr Co-axial Transmittion 18 Smart IR LED 3.6mm fixed lens(6mm optional) 4in1 Video Mode Change by UTC Control Day / Night True Vision ABS PVC Outdoor IP66-67 Material [FCC,CE,RoHS,GMP Certified]
All types of Electric Terminals and accessories for control panales .
ATM machines, water - purifiers, softners, filters, voltage protector.
Solar inverter solar panel, online ups, solar water pumps and controller, DCDB, ACDB, lift inverter.Exporting and services
Battery terminal clamps provided by us are efficiently used for connecting 12 volts or 24 volts electrical cables with lead-acid battery or battery bank. Our lead battery clamps are corrosion resistance, malleable with low melting points, thus providing excellent conductivity and aptly suitable for battery terminals. We also make battery terminal clamps with nylon because of its high melting point and superior abrasion resistance. NuWay Industries Pvt. Ltd. is well- known for their diverse product line and state-of-the-art manufacturing strategy. From design to product delivery we cater finest battery terminal clamps to your industry. NuWay Industries Pvt. Ltd. is a leading manufacturer of Nylon 6 grade battery terminal clamps. We feel proud in meeting the highest quality specifications, made possible through advanced machinery, on-site engineered and custom-built equipments. Let’s take a look on some of the attractive features of battery terminals which make us different from others
Nuway Industries Pvt. Ltd. is one of the leading Manufacturer, Supplier and exporter of SMC DMC products in Pune, Maharashtra, India. The quality we deliver is unmatched and second to none. Full form of DMC is Dough Molding Compound. In DMC compounding/formation, used Glass fibre is chop strand form. Materials consistence in DMC is Fiber chop 17%-18%, unsaturated Polyester Resin 28-30%, Filler material like ATH and CaCo3 40%-45%, others are catalysts and pigments. Glass Fiber and other chemicals are mixed in imported mixing machine. Due to it’s dough properties, any shape of insulator and Busbar support can be made.
We are engaged in manufacturing, supplying and exporting high quality Bimetallic Lugs. NuWay Industries Pvt. Ltd. is the leading manufacturer, supplier and exporter of high quality Bimetallic Lugs in Pune, Maharashtra, India. For meeting varied requirements of the client, these Lugs are available in different specifications. Precisely Designed, Rugged Construction and ability to bear adverse conditions are some of the prominent features of our Bimetallic Lugs.
Battery Chargers And Batteries For Electric Sub Stations & Power Equipments & Solar Rooftop..
PROTOCONTROL offers Signal Isolators to isolate and convert field signals like resistance, current, voltage, frequency to 4-20 mA. These isolators find use in process control industries for signal isolation. Variety of models is available for specific applications. Transmitters are the field devices which receives signal from field sensors like temperature sensor (Pt 100, thermocouple) or load cell & convert these in suitable form like 4-20mA, O-20 mA, 0-10V as an input for panel instruments. In the field, many signals are generated such as motor current, armature voltage, position feedback in the form of change in resistance or signals obtained from various types of traducers in standard voltage or current form. These signals are not isolated from input and not suitable for transmission over long distance. Converters are specially developed to overcome these problems in transmission such as line drop, interference, ground looping, and non compatibility to standard processing unit. Salient features includes complete galvanic isolation between input output and control supply , Independent zero and span adjustments ,Stable current output eliminates need for special cable, shielding, The isolators are housed in din rail mounting engineering plastic enclosure. Special robust cast Al. enclosures suitable for field mounting are also available. These Isolators are extensively used in cement, fertiliser, chemical, and processing plants. Individual packing.