Three phase current transformers D363: inner hole 3*30mm, Ratio: 50/5A, 75/5A, 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A, 500/5A D364: inner hole 3*41mm, Ratio: 300/5A, 400/5A, 500/5A, 600/5A
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter. Features: 1:The structure of the self-locking, safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations 4:Isolated plastic case recognized according to UL94-V0 5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs Applications: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor,heating and ventilation system, air-condition equipment and automation â?? control system. 3:Current, power and energy monitoring device. 4:Relay protection device. Model Guide: 1) KCT-6: inner hole size: 6mm, Ratio: 5A/2.5mA, 10A/5mA, 20A/10mA 2) KCT-10: inner hole size: 10mm, Ratio: 5A/2.5mA, 20A/10mA, 60A/20mA, 75A/25mA, 1~75A/0.333V 3) KCT-16: inner hole size: 16mm, Ratio: 100A/33.3mA, 100A/40mA,120A/40mA, 200A/66.7mA, 100~200A/0.333V 4) KCT-24: inner hole size: 24mm, Ratio: 100A/40mA, 200A/40mA, 200A/66.7mA, 400A/80mA, 100~400A/0.333V 5) KCT-36: inner hole size: 36mm, Ratio: 300A/100mA, 400A/40mA, 500A/50mA, 600A/60mA, 300~600A/0.333V
Split core Current transformer: 1) HK-23: Inner hole 20*30mm, Ratio: 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A 2) HK-58: Inner hole 50*80mm, Ratio: 250/5A, 300/5A, 400/5A, 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A 3) HK-812: Inner hole 80*120mm, Ratio: 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A, 1200/5A, 1250/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A 4) HK-816: Inner hole 80*160mm, Ratio: 1000/5A, 1200/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A, 5000/5A, 6000/5A, 7500/5A, 8000/5A
Veikongs softstarters increase a motor's lifetime by protecting it from electrical stresses. They do so by letting you optimize starting currents that with conventional starting methods put lots of stress on the motor. With many built-in motor protection features, your motor is â safe in its hands. Veikong's softstarters are also installation-friendly and can cut your assembly and startup time by being easy to use and easy to learn. With everything that you need in one unit, from bypass contactor to overload protection, a single softstarter makes for a compact and complete starting solution. Furthermore, with many application specific features, veikong's softstarters can ultimately help you increase productivity. Torque control, pump cleaning and many more features let you do more than simply softstarting. Main benefits 1, secure motor reliability 2, improve installation efficiency 3, increase application productivity. Main featuresâ 1, offering: pstx, pst(b), pse, psr and pss 2, veikong's softstarters cover any motor application from 3 a to 2160 a 3, reduced starting current and less electrical stress on the motor and the network 4, fast and easy to install and set-up with a small footprint 5, reduced mechanical wear and tear on mechanical equipment.
1, vector control and torpue control 2, high torque 200% output at 0.25hz 3, easy installation and commissioning
1, power reange 1xac 230v 0.4kw to 3xac 400v 630kw 2, use in hd(heavy duty)or nd(normal duty) mode 3, expandability through i/o and pg card 4, integrated operating panel for simple, fast commissioning
High output string inverter for home solar system Maximum efficiency 98.2% Real-time yet accurate mppt algorithm to ensure the maximum benefits Wide input voltage range from 250v to 960v Provides professional yet economical solutions for home solar power system Dc switch (optional for users to choose) Dc surge protector (optional) Ac surge protector (optional) Built-in photovoltaic pool (optional) Built-in energy management module Best string inverter choice for large-scale photovoltaic power plants, commercial buildings Convenient maintenance of low cost Easy installation with removable cover Rustproof aluminum cover Flexible and mature monitoring solution for solar home power system All kinds of string inverter information can be displayed by setting the multi-function relay Smart grid management Built-in lvrt function Reactive power adjustable function Automatical load reducer when over frequency Remote active power limit control function
Power Transformer (35kV) Oil-immersed Transformer Products structure and technical features The oil-immersed transformer produced by our factory have these advantages: low loss, low noise, high short circuit strength and good appearance. We company create these prefect products of that each parameter has reached to advanced level among domestic similar products by combining advanced manufacture equipments and technology. Structure features: Core and main body: it is used iron core cutting line ,all inclined ladder joints and improving flux trend to eliminate flux saturation phenomenon of iron core in joints . By doing these, it reduces the no-load loss, no-load current and noise of transformers. Adopting pulling-plank structure, in order to strengthen the ability of withstanding short-circuit, we put many nails around pressing planks and bracing plates are used as support between H.V and L.V yoke, make the iron core be a whole. The iron core sheet are coated by glue which are specialized for silicon steel , so that all silicon steels can be bonded together to make the iron core be  integral one, this effectively enhances mechanical strength and plays a positive role in the core anti-rust. The low part of the body and the oil tank are supported through bracing plates adopt" high intensity electric laminated" technology, to guarantee the low part of oil-immersed transformer's body safe and reliable. Coil: The high-voltage(HV) coil adopts an interleaved-continuous structure, The low-voltage(LV) coil adopts an interleaved-continuous or spiral structure, are independently provided with voltage-regulating winding to balance the ampere turn of each winding-up, effectively lower the mechanical force to minimal level. In the transformer winding, there is a zigzag oil guide structure so as to fully cool all areas inside the winding, lower the temperature rise of the winding and the hot points of the winding and prolong the service life of insulation. Oil tank: the tank's structure of oil-immersed transformer is bell jar type or suspended type, have a good looking and high mechanical strength. It adopts" flanged joint" technology in every key point (such as annular tubes, pressure valves, switches,etc.), which effectively avoid leaking oil. Technical Parameter and features Technical specification 1,voltage:35kV 2,voltage regulation: on load tap regulation ,off circuit tap regulation 3,capacity range:
Rated Input Current:2mA Rated Output Current:2mA Turns ratio:1000:1 Phase Angle Error:less than 45'(2mA,50) Linear Range:0~1000V 0~10mA(50) Mounting(mm):PCB
Rated Input Current:5A Rated Output Current:2.5mA Turns ratio:2000:1 Phase Angle Error:less than 20'(1A,100) Linear Range:0~20A(100) Mounting(mm):D5.0 * Small size * High accuracy * Good consistency * Used for current and power measurement
Advantages of toroidal transformers 1. High efficiency and high performance price ratio Toroidal core has good electromagnetic performance, like high saturation magnetic flux density, high primary inductance and large unit magnetizing power capacity, which improve the utilization ratio of the core and the winding window area, and reduce the number of turns and the direct current resistance, and also greatly improve the overload capacity and load efficiency of the toroidal transformer. Based on these conditions, the product design does not need to consider more power margin and heat dissipation conditions, and also effectively control the cost. 2. Excellent no-load characteristics Toroidal core is wound with high permeability silicon steels, no gap on magnetic circuit, low magnetic resistance. Under the same power and magnetic field density, the no-load loss and exciting current of toroidal transformer are only 50%~70% of other transformers, which reduce the standby loss and improve the equipment operation reliability. 3. Low noise There is no gap of toroidal core, the silicon steels are tightly winded, and after the vacuum impregnation with pressure it becomes a whole. Even in the middle, high magnetic frequency, it will not cause noise due to magnetic expansion. This is what the EI, dry-type and other lamination cores cannot match. 4. Low magnetic flux leakage, low leakage inductance Toroidal core has a high saturation flux density, and the coil is uniformly distributed on the core, magnetic potential difference can effectively reduce the magnetic leakage. Normally, with the same transformer specifications, the magnetic flux leakage of toroidal transformer is only 1/10 of the EI one. The main coil is tightly and rationally layered winded, and then the leakage inductance of the primary and secondary coils can be better coupled to reduce the primary and secondary leakage inductance. 5. Safety of electrical structure There is a certain thickness of stacked dielectric film between the core and primary coils, primary coil and electrostatic shielding, electrostatic shielding and secondary coil, secondary coil and the installation plate, which completely isolates the electrical gap and is safe without maintenance. Therefore, isolated toroidal transformers have been widely used in medical equipment transformers.
Your search for three-phase transformer manufacturers ends at trutech products. Our offered transformer is the perfect example of technology and modernity. To search out more details about the product and price range of each unit, be in touch with us.
Material: We use high quality crgo steels with low iron-loss and high permeability in thickness of 0.05mm, 0.08mm, 0.1mm, 0.23mm, 0.27mm, 0.3mm and 0.35mm. Characteristic: The two halves of three phases put together and come into a closed flux path as an open structure. So bobbin and core can be produced separately, afterward put the core in bobbin, and then the production time can be reduced. Application: Various specifications e core are widely used in 50hz and 400hz three phases transformers, reactors, chokes and other magnetic components of electronic equipment.
Introduce: This product has advantages of low no-load losses, oil-free, flame self-extinguishing, moisture, crack-resistant and maintenance free. Now the entire place which used the ordinary dry type transformer can be replaced by amorphous one. It can be used for high-rise buildings, commercial centers, subways, airports, railway stations, factories and power plants, especially suitable for flammable, explosive high-demand places. Performance: - low-energy saving - high corrosion resistance - strong ability to withstand short circuit - low noise - low temperature and long service life Application area: - altitudeâ?¤1000m - environmental temperature -25+40 - indoor use
Introduce: The emc standard of frequency range of 150 khz-30mhz on restraining the conducted cm emi are becoming more serious in the application. Cm inductance & filter capacitor were used to restrain the cm emi. Ferrite core or common nano-crystalline core are popular in domestic market as common mode choke cores, but high high-frequency volume and impedance reduction from 150 khz to 30mhz due to the operating frequency limitation makes these cores unworkable. In this ease, nicore developed advanced higher property nano-crystalline common mode choke cores as solution for emc common mode choke cores requirement, and were applied to the emc of switch power modules, ups power supply, communication power supply, inverter, transducer, home appliance. Characteristics: - high initial permeability: 5~20 times higher than ferrite core - high saturate induction density: 2-3 times higher than ferrite core, not easy be saturated in high current fields - excellent temperature stability-with the serving temperature from -55 to 130"c for a long time. The curie temperature is higher. The properties are not changeable easily even in unstable working temperature. - good frequency flexibility-better controlling to the noise in different frequencies. - higher anti-unbalanced-current: specially made nano-crystalline emc common mode choke cores can guarantee 104 permeability when resist 80a/m unbalanced current bias field. Application area: - protection for accurate electronic equipment - common mode jams filtering for emi power - common filtering in single phase or three phase circuit
Material: iron core: crgo/crngo(z11, h12, h14, h18, h20, h50 Thickness: 0.35mm, 0.5mm. Origin: baosteel; jfe steel ; hitachi Standard: ei24-ei114(perforate or imperforate) Shape: ei, ee, tl, ui. Special standard: special dimension and style cores produced according to customers specifications. Application: electronic transformer, induction coil, ballast. Performance: power rating : 1-1000(w) Model: ei24-ei114
S(B) H15 Amorphous Alloy Transformer (10kV, 20kV) Amorphous Alloy Transformer Product introduction: Oil immersed transformer with amorphous alloy core is a new generation of energy-saving product. The iron core is the amorphous alloy material which imported from aboard. Its special advantages is low-load loss. Amorphous alloy transformer is widely used for urban and rural distribution network, especially applicable for the areas and users that pay attention to energy saving. Product features: No-load loss It has the amorphous alloy which is a kind of soft magnetic material with same character in different directions. Its magnetization power is low, resistivity is high and loss of eddy current is low. The no-load loss and no-load current of the iron core used in this kind of transformer is very low. Compared with silicon steel S(B)9 series transformer, the no-load loss decreases about 75% and it decreases about 65%, compared with silicon steel S(B)11. It reduces the operation cost. It is very energy-saving.
Wind Power Generation Transformer New Energy Dedicated Transformer Product structure and features General introduction With the continuous growth of China's economy, the demand for electricity surged, energy has become the main contradiction. Because the traditional coal-fired and fuel power generation caused serious environmental pollution, so in order to be consistent with environmental protection requirements, wind power as a clean energy production that has been developed rapidly in our country , has become the main direction to solve the energy shortage. We company develop a series of wind power generation combination substation, which can change 690V voltage generated by wind power dynamotor to 35kVor 10kV voltage through rising and changing voltage, then send to gird system or users, finally finish the task of wind power generation. So, wind power generation combination substation is the best matching product of wind power generation system. Structure and performance features 1, structure features A, main body adopts the structure of common box transformer. Assemble high-voltage load switch, plug-in fuse, transformer body, off-circuit tap-switches and other H.V components in a sealed tank, transformer oil as insulating medium, its size is small and performance is excellent . B, Overall combination type wind power substation is composed of H.V chamber, L.V. chamber, oil tank and radiator. Install chip radiator on the side of oil tank, the chip radiator is combined by guide pipe and cooling fin which can better adapt to high-power transformerâ??s cooling requirements. In order to prevent vandalism, to these cooling fins with weak mechanical, we will use steel shield that be punched cooling holes to enhance the protection. By substation, rise the voltage of power generated through wind dynamotor and merge into grids.
PV Power Generation Transformer New Energy Dedicated Transformer Product Introduction In order to meet the needs of our national PV power generation, our company developed two series of PV power generation transformers on the base of wind power generation combination transformers. 1, ZG(F)SF11-Z.G-â?¡/35 series three-phase split type off-circuit voltage-change PV power combination transformer The structure of this series of products is same as that of wind power generation transformers, except that L.V. side winding, outlet method and electrical equipments adopt special structures. L.V side is equipped with double-split winding and two outlets which can be connected with two PV generators at the same time, meanwhile, equipped with essential protective electric elements. This series of products are with characteristics of good electrical performance, small size, light weight, reliable operation, easy to install, high cost-effective, etc. Features of productsâ?? structure a, design thought: adoptsâ?� two generators, one transformerâ?� program, means two PV generators combines with one transformer. L.V side is equipped with double-split winding ,two outlets and L.V electric system which can be connected with two PV generators at the same time. b, users can rise one transformerâ??s output capacity under the capacity of same generators, which can save usersâ?? investment and operational cost. c, materials of transformersâ?? casings can be chosen according to different environmental requirements: conventional composite panels, stainless steel composite panels, non-metallic fiberglass cement, etc. d, casing material has a good level of protection and corrosion resistance, which can effectively prevent wind, rain, snow and salt erosion e, H.V. electrical equipments have five protection functions: H.V. fuse of substations and overload switchgear carry out interactive protection, prevent transformers working under the condition of lacking phase; H.V use three-position load switch that can be checked and repaired safely under the state of grounding; H.V overload switch and grid door of transformer chamber adopt â?? electric locking, realize the protection function of automatic power-off when mistakenly open the grid door. f, transformer chamber adopts natural ventilation and automatic controlling forced cooling exhaust devices, has a exhaust system which can be controlled automatically with temperature change, can effectively control and low chamberâ??s temperature, meet the need of full overload operation. g, low voltage equips with 690V main circuit breakers, over-voltage protection equipments , and we can design complete automatic measurement and intelligent control systems.
Casing of Transformer Casing of Transformer Product Introduction It is not necessary for general dry-type transformer to equip casing, means the protective degree is IP00, if need to be equipped with casing, protective degree is IP20, Casing is constituted by a safety shield to prevent accidental electrocution. Under the conditionof having dripping water, the transformer can be equipped with casing of that protective level is IP23. According to users special requirements, we can provide casing with IP54 protective level. Temperature Controlling and Cooling Devices Temperature controlling device Transformer adopts BWDK temperature controlling device, temperature measuring component is in the top of low voltage winding that can detect automatically and cyclically display working temperature of three-phase winding. When the temperature of winding reaches setting value , thermometer can automatically start the fan, stop the fan, signal transfer output, tripping output, etc. Air cooling device Transformer is equipped with dedicated Axial flow cooling fan, transformers capacity can be increased by 40%, even more under the condition of forced- air cooling.