Features:
Wide range of system current Ratings
Hinged terminal cover
Various mounting options like DIN rail mounting, Wall mounting
Terminal with self lifting screw with dual connection facility giving access from both sides of transformers
1. High precision: 0.2, 0.1 or 0.05 Class 2. Good linearity; 3.Ratio : 1000:1, 2000:1; 2500:1 4. 6A, 15A,40A, 60A,80A,100A,120A,160A, 200A etc. 5. The fly leads cable length can be customised ; 6. The inner hole diameter can be chosen as your requirement; 7. It can be applied in Electricity meters .
DC immune Current transformer for Electricity meter -Adopted high permeability core, high accuracy , good linearity; -Anti-combustion plastic case ; -Encapsulated with epoxy resin with strong insulation ability; -DC immune function with good DC error , conform to IEC 62053-21; - Customised shield to against the external magnetic field .
1. DC immune CT with good DC error ; 2. High precision: 0.2, 0.1,0.05 Class, 3. Good linearity; 4. Max Current:6A,10A,30A,40A,60A,80A,100A,120A,160A,200A ; 5. Ratio :1000:1; 2000:1 or 2500:1 ; 7. Pin connection/ PCB mounting ; 8. It applied in Electricity meters .
KF series split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor voltage. These CTs can be mounted without removing existing cables for easily installation.
Supplier: Wire wound resistors, pot meters, current transformers, rheostats
Supplier: Energy meters and current transformers
Supplier: Electrical measuring instruments, meters, volt meters, current transformers
Supplier: Electrical engineering products like digital energy meter, current transformer, rmu's etc.
Resin cast current transformers are available for metering and protection application. These current transformers are mainly fabricated according to client’s specification. Ct coils are encapsulated in cast resin (polyester / epoxy). Secondary terminals are provided with either screws or studs. The main insulation between primary and secondary and earth is obtained by this epoxy resin. These transformers are of compact design with high mechanical and electrical properties. These are non-hygroscopic and hence give very good insulation properties even in given humid conditions. General particulars Rated voltage: 11 kv Rated primary current: 100 a Rated secondary current: 1a or 5a Rate burden: 5va Rated frequency: 50hz Accuracy class: 0.5 or 0.5s Temperature: as per is-2705/1992 Highest system voltage: 12kv Insulation level: 28kvrms/75kv(p) Stc: 13.1ka for 1 sec Continues thermal current: 1.2 times of rated current Core material: crgo Copper wire material: enameled wire as per is-4800 part-4 or iec-317 Insulation class/material: epoxy resin Secondary terminal: m5 brass bolt with nut &washer or m5 threaded bush with screw &washer Primary terminal p1 & p2 size and material Mounting base: ms 5mm thick zinc plated Rountine test :as per is-2705/1992