Main technical parameters: Power supply voltage: 220V/AC ~ 240V/AC Power frequency: 50 ~ 60Hz Ambient Light:
operating voltage DC 9-16V consumption current â?¤18mA(DC12V) operating temp -10ºC~+50ºC installation mode ceiling mounted installation height about 2.5~6m detecting distance Ï?8m detecting angle 360 degrees alarm output N.O./ N.C. optional anti-dismantle switch N.C. dimension Ï?106*36mm
operating voltage DC 9-16V consumption current â?¤18mA(DC12V) operating temp -10ºC~+50ºC installation mode ceiling mounted installation height about 2.5~6m detecting distance Ï?8m detecting angle 360 degrees alarm output N.O./ N.C. optional anti-dismantle switch N.C. dimension Ï?106*36mm
PT1XX Series : PT111 Series, PT123 Series, PT124 Series, PT127 Series, PT131 Series. High Temperature Melt Pressure Transducer (Melt Pressure Sensor) High Temperature Melt Pressure Transmitter Product Description Product Introduction PT1xx6B Series High Temperature Melt Pressure Transmitter. The main applications are under the high temperature melt, fluid, gas pressure measurement and control fields in petroleum chemical industry, chemical fiber textile machinery, non-woven fabric, nonwoven, plastic, rubber, extrusion equipment, etc. With high accuracy, good stability, output signal big, dynamic of good, strong commonality, etc. Performance Parameters: Pressure Range0 ~ 0.5 MPa ~ 150 MPa ( 0 ~ 100psi ~ 20000psi ) Accuracy±1.0% FS Power24VDC ( 9 ~ 36 V DC ) Output Signal Current signal: 4~20mA, 0~20mA; Voltage signal: 0~10V, 0~5V, 1~10V, 1~5V. Probe Heat Resistance PT1116B Series: 300°C; PT1236B,PT1246B,PT1276B,PT1316B Series: 400°C Temperature Drift=500MΩ/500VDC Mechanical Connections1/2"-20UNF, M10x1.5, M12x1.5, M14x1.5, M18x1.5, M22x1.5 etc. (Optional) Electrical Connections6PIN (SD02106P/SD02106S) Thermometric Config Thermocouple: E, J, K, S type etc.; (PT4626B Series Optional) Thermal Resistance: Pt100 etc. (PT4626B Series Optional) Order Format: Example1: PT1116B-350bar-M18-150-0~10V Note: Product design Model "PT1116B". Function code "B" stands for melt pressure transmitter. Coating code "Null" stands for without coating . Pressure range: 0 ~ 350bar. Thread size : M18 * 1.5. Rigid stem length:150mm . Pressure output signal: 0~10V. Example2: PT1236B-5000psi-1/2"-20-150/470-4~20mA Note: Product design Model "PT1236B". Function code "B" stands for melt pressure transmitter. Coating code "Null" stands for without coating . Pressure range: 0 ~ 5000 psi. Thread size : 1/2"-20UNF . Rigid /Flexible length:150mm/470mm . Pressure output signal: 4~20mA Example3: PT1316B-50MPa-1/2"-20-150/470-Pt100-4~20mA Note: Product design Model "PT1316B". Function code "B" stands for melt pressure transmitter. Coating code "Null" stands for without coating . Pressure range: 0 ~ 50MPa. Thread size : 1/2"-20UNF . Rigid /Flexible length:150mm/470mm . Thermometric Config : Pt100 Thermal Resistance Temperature Sensor . Pressure output signal: 4~20mA . Our Services 3 Years Warranty
Usage: Pressure Sensor, Direct spo2 sensor connected to the monitor, no need for extension cable. Compatible Mode: AS/3, CS/3, CH/S, CH/2S, CH-RS, CG/2S, Cardicap I, Cardicap II, Cardicap 5, Capnomac Ultima, Light Monitor: M-Estpr, Oscar II, OSP-200, Satlite Trans, SatliteTrans Plus, System 5ULTS00, ULTSIO, ULTSVI, ULTSVO
Usage: Pressure Sensor, Direct spo2 sensor connected to the monitor, no need for extension cable. Compatible Mode: Nellcor N100, N180, N200, N-20, NPB-50, NPB-75, NPB-290, NPB-295, N-390, N-395, N-3000, N-6000
Product Description: SR-902 Main Features: Auto reset after alarm MCU process Sensor with high stability and low power consumption Detecting natural gas and LPG SMT adopted Technical specification: Operating voltage: AC 220V or DC 9-16V Standby current: less than 90mA or less than 30mA (low power consumption) Alarm current: less than 100mA or less than 40mA (low power consumption) Rated power: less than 3W (AC 220V) Operating temp.: -10 to +50 degrees Working humidity: less than 95%RH Alarm mode: network output / sound & flash alarm / RF Alarm volume: more than 85dB/m Alarm density: 10%LEL Alarm output: relay output (N.C.and N.O. optional) / RF signal Dimension: 70L*40W*110Hmm
Quick Details Type:Percussion Hammer Brand Name:BATERSUARG Place of Origin:Beijing, China (Mainland) Instrument classification:Class I Product Name:Canine OvulatIon Detector Certificate:CE ISO Color:Yellow Function:Diagnose Application:ovulation detector Supply Ability:10000 Unit/Units per Week Packaging & Delivery Packaging Details Carton Packaging Port Shanghai,Tianjin port Lead Time : Quantity(Units) 1 - 1000 >1000 Est. Time(days) 5 To be negotiated Product Description Application Accurately master the best breeding time Test Method Fully automatic one-time test Test Speed Within 3 seconds Net Weight 300 g Electric Power a 9 volt battery Display LCD screen, about 2.6 inches Measuring range 10-1990 Working temperature 0-50°c Maximum humidity 85%
product description: The automatic dog estrus ovulation tester consists of three parts: a measuring probe, a digital display for reading data, and a handle with a standard 9 volt battery. The switch is located on the back of the handle. There are two parallel (parallel) electrodes at the top of the probe for measuring the resistance of the vaginal mucus. The current generated by the two electrodes and the electric field generated by this trace current are harmless to animals and humans. The ovulation tester is made of polyethylene with good chemical stability and insulation. The entire instrument is water resistant so it can be cleaned to keep the instrument clean and maintain.
Details: 1.Connectors: 8 pin 2.Direct spo2 sensor connected to the monitor, no need for extension cable. 3. Compatible models: 25C, C1, C3, M3, M5, MP20, MP30, MP50, MP70, MP80, VM5, VM6, VM8 (Philips tech) Delivery Time: 3-5 days Shipping: DHL/FedEx/EMS/UPS/TNT Packing: 1pcs pack into one PU bag, then pack inside a small carton box Types of Patient Finger For Your Choice: 1. Adult finger clip 2. Adult silicone soft tip 3. Pediatric finger clip 4. Pediatric silicone soft tip 5. Infant silicone soft tip 6. Neonate silicone wrap 6. Neonate "Y" type 7. Adult ear clip Our Advantages: 1. Factory price is more competitive. 2. Fast delivery(3-5 days, we are a manufacturer, have enough products in stock.) 3. All products are made of medical material with very good quality(OE, ISO, ect. certificates) 4. Samples available(accept trail order) 5. One piece MOQ is acceptable. 6. OEM & ODM service 7. Adult/infant/pediatric/neonatal patient finger types are available FAQ 1. Are you a trading company or a manufacturer with your own factory? We are a professional manufacturer with our own R&D team. 2. Can I have my own Logo on the product? Yes, your own drawing is welcomed. We can design and make your logo on the product, but the cost need to be paid by your side. 3. Can we visit your factory? Of course. Welcome to visit our factory. Our professional technicians are willing to show you more details of our products. 4.Does your company have any certificates? Yes, we are certified with CE and ISO13485. Its our duty to offer you high quality products with best service and the most competitive price. 5. When can you deliver products? It depends on the quantity. Most of our products are in stock. For common orders, we can arrange shipment immediately after we get your payment. Main Products We Supply: Reusable Spo2 Sensor Disposable Spo2 Sensor Spo2 Extension Cable ECG Cable with leadwires EKG Cable with leadwires, EKG /ECG Trunk Cable Temperature Probe Fetal Transducer ECG Electrode EEG Cable IBP Cable and Transducer NIBP Cuff and hose
Place of Origin: Henan, China (Mainland) Product Categories: Monitor accessories Use: Detection Usage: Pressure Sensor Brand Name: Biolight Compatible Model: A3, A5, A6, A8, M7000, M8000 Technical: Digital Tech Instrument Classification: Class II Type: Adult finger clip Cable Material: Medical TPU Cable Color: Gray Cable Length: 1M Connector: 7pin Certificate: CE, ISO13485 Warranty: 12 months Delivery time: 3-10 days Shipping: DHL/FedEx/EMS/UPS/TNT Packing: 1pcs pack into one PU bag, then pack inside a small carton box
OXY-F4-N Datex Ohmeda S/5 SpO2 Sensor 10pin for adult finger clip shell Features 1. Medical TPU jacket, double shiled 2. Imported LED and PD 3. ABS Connector 4. Blood Oxygen Saturation Accuracy Range (Arms):25-250 bpm±2 bpm; Pulse Rate Declared Accuracy Range(Finger):45-99%, (85-99)% SpO2±1%; (70-84)% SpO2±2%; Application: Patient size: Adult use Compatible monitor: Datex-Ohmeda: Aespire, Aespire 15, AS/3, AS/3 Compact, CS/3, S/5, S/5 Compact, CS/3,CH/S, CH/2S, CH-RS, CG/2S, Cardiocap I, Cardiocap II, Cardiocap 5, Capnomac Ultima, Light Monitor, M-NESTPR, M-Estpr,Oscar II, OSP-200, Satellite Trans, Satellite, Satellite Plus II, Trans Plus, System 5, ULTS00, OXY-E4-N, ULTSIO, ULTSVI, ULTSVO(direct connect)
ETO-A1 Ethylene Oxide Sensor ETO Sensor Description Alphasense is expanding its line of Electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ethylene Oxide (C2H4O) The ETO is a general purpose sensor, primarily developed for monitoring Ethylene Oxide but also capable of measuring other volatile organic compounds (VOCs). Our toxic evaluation board allows easy adjustment of the bias voltage to optimise this sensor for the required application. See application note AAN113. Available in A and B series ETO-A1 Ethylene Oxide Sensor ETO Sensor Specifications * Range: 100 ppm EtO limit of performance warranty * Sensitivity: 2000 to 3200 nA/ppm in 20ppm EtO * Response time t90: < 150s from zero to 20ppm EtO * Resolution: < 0.1 RMS noise (ppm equivalent) * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120kPa * Humidity range: 15 to 90% rh continuous * Weight: < 6 g
H2-BF Hydrogen Sensor H2 Sensor Description Alphasense is expanding its line of electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Hydrogen (H2) The Hydrogen sensor has excellent ppm sensitivity for low concentrations to 2,000ppm H2. The very low sensitivity to CO makes this one of the most selective Hydrogen sensors on the market. As with all Hydrogen sensors, temperature compensation for sensitivity must be applied carefully. Available in A series. H2-BF Hydrogen Sensor H2 Sensor Specifications * Range: 5,000 ppm H2 limit of performance warranty * Sensitivity: 10 to 25 nA/ppm in 400ppm H2 * Response time t90: < 55s from zero to 400ppm H2 * Resolution: < 0.8 RMS noise (ppm equivalent) * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh * Weight: < 13g
Remote Particle Counter Model P235 The P235 remote particle counter measures 0.5 µm and 5.0 µm with a flow rate of 0.1 CFM (2.83 LPM). Integration is easy into a real-time monitoring or building management system via Modbus RTU or Modbus ASCII. The P235 is the smallest remote particle counter in the market and has easy mounting options. The P235 complies with ISO 21501-4 and includes a 2 year limited warranty. P235 Remote Particle Counter Features & Benefits * Measures 0.5 µm and 5.0 µm * 0.1 CFM (2.83 LPM) flow rate * Measures 2 channels of simultaneous data * Long life laser diode * Modbus RTU or Modbus ASCII outputs * Concentration limit of 2,000,000 per ft3 * Complies with ISO 21501-4 and JIS B9921 standards * Lightweight stainless steel enclosure * Easy to clean and wipe down * 2 year limited warranty
RF Microwave Meter Measure the electromagnetic field radiation intensity that is produced from welding equipment, microwave oven leakage, and other environmental safety concerns The Microwave Meter is calibrated precisely on the frequency value 2.45 GHZ (microwave oven). Features maximum and minimum hold, an audible alarm, and a zero adjustment to eliminate background EMF. The display also indicates overload and low battery. Comes with a soft carrying case and standard 9V battery, which provides approximately 100 hours of use. Dim: 5" x 2" x 1¼" (127 x 51 x 32 mm). Weight: 5.4 oz (153 g). 840046 RF Microwave Meter Specifications * Display: 3¾ digits, maximum reading 3999 * RF Power Density: 0.003 to 2.700 mW / cm2 * RF Frequency: 50 MHz to 3.5 GHz * Microwave Frequency: 2450 MHz * Resolution: 0.001 mW / cm2 * Accuracy: ±2 dB at 2.45 GHz ±50 MHz * Operating Temperature: 41 to 104 deg F (5 to 40 deg C) * Operating RH:
This STM85 microcontroller based control card can be used to switch ON & OFF 17relays via serial communication (RS232 or UART TTL) .It can also read the status of 8-digit inputs .The relay output status & digital input status is continuously sent out as RS232 data string .It operates in 9600BPS,8-N-1 mode .This control card can be controlled via weighing scale PCB or via PC.
CO/H2S-D2 Miniature Size Carbon Monoxide + Hydrogen Sulfide Sensor Introduction The world wide use of multigas, portable, personal safety monitors has grown since the 1970s to include an ever increasing number of industries. The one requirement in common to the majority of these instruments is the need to measure both Carbon Monoxide and Hydrogen Sulfide simultaneously. Alphasense now offers a compact, dual gas sensor which allows designers to reduce significantly instrument size and cost. The D2 sensor provides a unique approach to the dual gas sensor in both its size and working electrode configuration. The use of a high capacity filter over the Carbon Monoxide working electrode eliminates Hydrogen Sulfide cross sensitivity to Carbon Monoxide. Proven in the field over many years, these sensors perform well even under long term, challenging conditions. * Range: 1000 ppm CO limit of performance warranty * Range: 100 ppm H2S limit of performance warranty * Sensitivity: 27 to 55 nA/ppm in 400ppm CO * Sensitivity: 90 to 160 nA/ppm in 20ppm H2S * Response time t90: < 25 (s) from zero to 400ppm CO * Response time t90: < 30 (s) from zero to 20ppm H2S @ 20 deg C * Temperature range: -30 to 50 deg C * Humidity range: 15 to 90 %rh continuous * Pressure range: 80 to 120kPa
Carbon Monoxide Sensor CM8 CM8 Carbon Monoxide Sensor Features: 1. More than ten years long life, electrochemical principle 2. Low sensitivity to ethanol; 3. Can reduce the influence of various interference gases, good linear output characteristics; 4. Consistency is very good; 5. The carbon monoxide gas selectivity and repeatability is very good; 6. The sensor signal output and the concentration of carbon monoxide gas into a linear relationship; 7. The leading production technology and new advanced materials; 8. Electrolyte pollution, materials comply with RoHS requirements; 9. Strong anti-interference; 10. The shell thicker will never rust, the new material used in component feet is conductive. CM8 Carbon Monoxide Sensor Typical Applications: 1. Carbon monoxide detector alarms 2. Car alarms 3. Smart furniture 4. Commercial carbon monoxide detector 5. Industrial carbon monoxide detector 6. Indoor parking ventilation control 7. Portable carbon monoxide concentration meter 8. CO detection alarm. CM8 Carbon Monoxide Sensor Main parameters: * Carbon monoxide detection range: 0-10000ppm * Detection accuracy < 3% * Putput current: 0.8-2.0nA / ppm * Response time:
Combustible gas detector G-series for wall mounting G-series Combustible Gas Detectors Gases * Methane, CH4 * Liquid Petroleum Gas, LPG * Hydrogen, H2 * Propane, C3H8 * Ethylene, C2H4 * Ethyl alcohol, C2H5OH * Methanol, CH3OH * Acetone, C3H6O * Isopropyl alcohol, C3H8O * Iso/n-Butane, C4H10 * Toluene, C7H8 * Petrol Vapors On request: other combustible gas detectors G-series Combustible Gas Detectors Features * Pellistor (Catalytic Bead) sensor * Power supply 24 Vdc for output 4-20 mA * Power supply 24 Vac for output 2-10 Vdc * Measuring ranges: see ordering on page * IP65 enclosure with quick locking screws * Digital measurement value processing incl. temperature compensation * Internal function control with integrated hardware watchdog * Data / measured values in micro controller of sensor unit, therefore simple exchange uncalibrated calibrated * High accuracy, selectivity and reliability * Low zero point drift * Hardware & software according to SIL2 compliant development process * Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration G-series Combustible Gas Detectors Options * LCD display * LCD display for values & operation, 2 x open-collector for horn & warning lamp. * Duct mounting set available for sensing combustible gas in ventilation ducts.