H2-BF Hydrogen Sensor H2 Sensor Description
Alphasense is expanding its line of electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen (H2)
The Hydrogen sensor has excellent ppm sensitivity for low concentrations to 2,000ppm H2. The very low sensitivity to CO makes this one of the most selective Hydrogen sensors on the market.
As with all Hydrogen sensors, temperature compensation for sensitivity must be applied carefully.
Available in A series.
H2-BF Hydrogen Sensor H2 Sens or Specifications
* Range: 5,000 ppm H2 limit of performance warranty
* Sensitivity: 10 to 25 nA/ppm in 400ppm H2
* Response time t90: < 55s from zero to 400ppm H2
* Resolution: < 0.8 RMS noise (ppm equivalent)
* Temperature range: -30 to 50 deg C
* Pressure range: 80 to 120 kPa
* Humidity range: 15 to 90 % rh
* Weight: < 13g
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) Description Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology. H2S-AE Hydrogen Sulfide Sensor size: 20mm diameter, the industry standard size for portable gas detectors With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S. H2S-AE Hydrogen Sulfide Sensor (H2S Sensor) Specifications * Range: 2,000 ppm H2S limit of performance warranty * Sensitivity: 65 to 110 nA/ppm in 400ppm H2S * Response time t90: < 25 (s) from zero to 400ppm H2S * Resolution: < 0.5 RMS noise (ppm equivalent) * Temperature range: -30 to 50 'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6g
H2S-A1 Hydrogen Sulfide Sensor H2S Sensor Description Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology. H2S-A1 Hydrogen Sulfide Sensor size: 20mm diameter, the industry standard size for portable gas detectors With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S. H2S-A1 Hydrogen Sulfide Sensor H2S Sensor Specification * Range: 100ppm H2S limit of performance warranty * Sensitivity: 550 to 875 nA/ppm in 20ppm H2S * Response time t90: < 35s from zero to 20ppm H2S * Resolution: < 0.05 RMS noise (ppm equivalent) * Temperature range: -30 to 50'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6 g Matched Transmitter board for H2S-A1 H2S Sensor 4-20 mA Digital Transmitter Board * Factory calibration, custom-set for immediate use * Digital zero, sensitivity and temperature compensation * Digital and 4-20mA output * Biased or unbiased operation * Calibration and range change
Supplier: Wired magnetic door sensors.
Carbon Monoxide Sensor CM8 CM8 Carbon Monoxide Sensor Features: 1. More than ten years long life, electrochemical principle 2. Low sensitivity to ethanol; 3. Can reduce the influence of various interference gases, good linear output characteristics; 4. Consistency is very good; 5. The carbon monoxide gas selectivity and repeatability is very good; 6. The sensor signal output and the concentration of carbon monoxide gas into a linear relationship; 7. The leading production technology and new advanced materials; 8. Electrolyte pollution, materials comply with RoHS requirements; 9. Strong anti-interference; 10. The shell thicker will never rust, the new material used in component feet is conductive. CM8 Carbon Monoxide Sensor Typical Applications: 1. Carbon monoxide detector alarms 2. Car alarms 3. Smart furniture 4. Commercial carbon monoxide detector 5. Industrial carbon monoxide detector 6. Indoor parking ventilation control 7. Portable carbon monoxide concentration meter 8. CO detection alarm. CM8 Carbon Monoxide Sensor Main parameters: * Carbon monoxide detection range: 0-10000ppm * Detection accuracy < 3% * Putput current: 0.8-2.0nA / ppm * Response time:
CO/H2S-D2 Miniature Size Carbon Monoxide + Hydrogen Sulfide Sensor Introduction The world wide use of multigas, portable, personal safety monitors has grown since the 1970s to include an ever increasing number of industries. The one requirement in common to the majority of these instruments is the need to measure both Carbon Monoxide and Hydrogen Sulfide simultaneously. Alphasense now offers a compact, dual gas sensor which allows designers to reduce significantly instrument size and cost. The D2 sensor provides a unique approach to the dual gas sensor in both its size and working electrode configuration. The use of a high capacity filter over the Carbon Monoxide working electrode eliminates Hydrogen Sulfide cross sensitivity to Carbon Monoxide. Proven in the field over many years, these sensors perform well even under long term, challenging conditions. * Range: 1000 ppm CO limit of performance warranty * Range: 100 ppm H2S limit of performance warranty * Sensitivity: 27 to 55 nA/ppm in 400ppm CO * Sensitivity: 90 to 160 nA/ppm in 20ppm H2S * Response time t90: < 25 (s) from zero to 400ppm CO * Response time t90: < 30 (s) from zero to 20ppm H2S @ 20 deg C * Temperature range: -30 to 50 deg C * Humidity range: 15 to 90 %rh continuous * Pressure range: 80 to 120kPa
Carbon Monoxide Sensor CM8 CM8 Carbon Monoxide Sensor Features: 1. More than ten years long life, electrochemical principle 2. Low sensitivity to ethanol; 3. Can reduce the influence of various interference gases, good linear output characteristics; 4. Consistency is very good; 5. The carbon monoxide gas selectivity and repeatability is very good; 6. The sensor signal output and the concentration of carbon monoxide gas into a linear relationship; 7. The leading production technology and new advanced materials; 8. Electrolyte pollution, materials comply with RoHS requirements; 9. Strong anti-interference; 10. The shell thicker will never rust, the new material used in component feet is conductive. CM8 Carbon Monoxide Sensor Typical Applications: 1. Carbon monoxide detector alarms 2. Car alarms 3. Smart furniture 4. Commercial carbon monoxide detector 5. Industrial carbon monoxide detector 6. Indoor parking ventilation control 7. Portable carbon monoxide concentration meter 8. CO detection alarm.
ETO-A1 Ethylene Oxide Sensor ETO Sensor Description Alphasense is expanding its line of Electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ethylene Oxide (C2H4O) The ETO is a general purpose sensor, primarily developed for monitoring Ethylene Oxide but also capable of measuring other volatile organic compounds (VOCs). Our toxic evaluation board allows easy adjustment of the bias voltage to optimise this sensor for the required application. See application note AAN113. Available in A and B series ETO-A1 Ethylene Oxide Sensor ETO Sensor Specifications * Range: 100 ppm EtO limit of performance warranty * Sensitivity: 2000 to 3200 nA/ppm in 20ppm EtO * Response time t90: < 150s from zero to 20ppm EtO * Resolution: < 0.1 RMS noise (ppm equivalent) * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120kPa * Humidity range: 15 to 90% rh continuous * Weight: < 6 g