H2S-A1 Hydrogen Sulfide Sensor H2S Sensor Description
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.
H2S-A1 Hydrogen Sulfide Sensor size:
20mm diameter, the industry standard size for portable gas detectors
With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.
H2S-A1 Hydrogen Sulfide Sensor H2S Sensor Specification
* Range: 100ppm H2S limit of performance warranty
* Sensitivity: 550 to 875 nA/ppm in 20ppm H2S
* Response time t90: < 35s from zero to 20ppm H2S
* Resolution: < 0.05 RMS noise (ppm equivalent)
* Temperature range: -30 to 50'C
* Pressure range: 80 to 120 kPa
* Humidity range: 15 to 90 % rh continuous
* Weight: < 6 g
Matched Transmitter board for H2S-A1 H2S Sensor
4-20 mA Digital Transmitter Board
* Factory calibration, custom-set for immediate use
* Digital zero, sensitivity and temperature compensation
* Digital and 4-20mA output
* Biased or unbiased operation
* Calibration and range change
NO-AE Nitric Oxide Sensor (NO Sensor) Description
Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology.
NO-AENitric Oxide Sensor size:
20mm diameter, the industry standard size for portable gas detectors
The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers.
Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes.
The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.
NO-AE Nitric Oxide Sensor (NO Sensor) Specification
* Range: 5,000ppm NO limit of performance warranty
* Sensitivity: 40 to 80nA/ppm in 250ppm NO
* Resolution: < 1 RMS noise (ppm equivalent)
* Response time t90: < 75s from zero to 250ppm NO
* Temperature range: -30 to +50'C
* Pressure range: 80 to 120 kPa
* Humidity range: 15 to 90 % rh continuous
* Weight: < 6 g
Matched Transmitter board for NO-AE NO Sensor
4-20mA Digital Transmitter Board
* Factory calibration, custom-set for immediate use
* Digital zero, sensitivity and temperature compensation
* Digital and 4-20mA output
* Biased or unbiased operation
* Calibration and range change
AC Input Microwave Motion Sensor - Highbay Version
AC Input Microwave Motion Sensors
Microwave Motion Sensors AC Input
HNS203HB
5.8GHz C-band microwave motion sensor, tri-level dimming control.
Operating voltage: 120~277V AC, 50/60Hz.
Rated load: 400W @ 120VAC, (capacitive)
Features
5.8GHz C-band microwave motion sensor, tri-level dimming control.
Operating voltage: 120~277V AC, 50/60Hz.
Rated load: 400W @ 120VAC, (capacitive)
800W @ 200~277VAC, (capacitive)
Stand-by power: ?1w.
Dual-PD technology, real Da ylight mo nitoring function for built-in application.
Zero-cross point operation, protect the sensor relay against the in-rush current, secure the max. load and life time of the relay .
Detection range up to 18m in diameter.
Mounting height: 10~12m.
Operation temperature:-20+70
RoHS compliant.
IP rating: IP20.
Setting
Detection range
Detection range can be reduced by selecting the combination on the DIP switches to fit precisely each application.
Hold-time
Hold-time means the time period to keep the lamp on 100% after motion detected.
*when hold-time set as 3s, sensor enters into test mode, this test mode is mainly for users to choose the desired detection range.
In this mode, the daylight sensor is disabled, when there is no motion, fixture keeps off, when there is motion detected, fixture keeps a cycle of 3s on and 2s off.
Daylight sensor
Daylight sensor means the daylight threshold to enable or disable the sensor function.
"Disable": The sensor works always, even during daylight.
"50lux": The sensor works only in twilight.
"10lux, 2lux": The sensor works only in the dark.
Stand-by period
This is the time period that the lamp remains at a low light level before it is completely switched off in the long absence of people.
"+" : means bi-level dimming control, the fixture never switch off.
Stand-by dimming level
This is the dimmed low light level you would like to have after the hold-time in the absence of people.
*0% means on/off control.
10%--Vdim=1.5Vdc 30%--Vdim=3.0Vdc50%--Vdim=5.0Vdc
5V/12V DC Input Microwave Motion Sensor - Standard Version
DC Input Motion Sensor Module
Adjustable Motion Sensor Module
HNS101
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
5V DC high-low voltage output signal.
Features
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:�?�25mA.
5V DC high-low voltage output signal.
Super compact, flexible to be integrated into any suitable fixtures.
Dual-PD technology, real Lux-Off function for built-in application.
8 pin DIP switch setting, multiple options to meet different customer demands. Detection range up to 12m in diameter.
Mounting height: 3~6m.
Operation temperature: -20�?? ~ +70�??.
RoHS compliant.
Settings
Detection range
Detection range can be reduced by selecting the combination on the DIP switches to fit precisely each application.
Hold-time
Hold-time means the time period to keep the lamp on 100% after motion detected.
*when hold-time set as 3s, sensor enters into test mode, this test mode is mainly for users to choose the desired detection range. In this mode, the daylight sensor is disabled, when there is no motion, fixture keeps off, when there is motion detected, fixture keeps a cycle of 3s on and 2s off.
Daylight sensor
Daylight sensor means the daylight threshold to enable or disable the sensor function.
"Disable":The sensor works always, even during daylight. w50lux, 25lux": The sensor works only in twilight.
"10lux, 2lux": The sensor works only in the dark.
5V/12V DC Input Microwave Motion Sensor Remote Controllable Version
Remote Control DC Input Motion Sensor
Motion Sensor Module DC Input
HNS111
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
Features
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
5V DC high-low voltage & PWM output signal(0~10v version available on request)
Super compact, flexible to be integrated into any suitable fixtures.
Dual - PD technology, real Lux -Off & Daylight monitoring function for built-in application.
IR remote commissioning, easy setting and user friendly.
Detection range up to 12m in diameter.
Mounting height: 3~6m.
Operation temperature: -20 ~ +70
RoHS compliant.
Settings(Remote control IR12)
Permanent ON/OFF function
Press ON/OFF button, fixture goes to permanent on or permanent off mode, sensor is disabled.
*press "Auto" ,"Reset" or "Ambient learn" to quit this mode.
Dim +/-
Press "Dim" button to automatically dim up or down the light brightness during hold-time from 10% to 100%. Another press to lock it down when desired brightness is achieved.
*after desired brightness is locked down, if user wants to dim again reversely, just press the Dim button again and then lock down the new brightness again.
Sensor mode
Press "Auto" button, the sensor starts to work and all settings remain the same as the latest status before the light was switched on/off.
Reset function
Press "Reset" button, all settings go back to factory default settings.
Factory default settings Sensitivity=100%
Daylight sensor=disable
Hold time=90s
Twilight time=5min
Twilight level=10%
Ambient learn
Press "Ambient learn" button, the latest surrounding lux value overwrites previous lux value learned, and set as the daylight threshold. This feature enables the fixture to function well in any real application circumstance.
Test mode
"Test mode" is for testing purpose only, for users to check the functionality and choose the desired detection range. The sensor goes to test mode automatically after pressing this button.
Users can quit this mode by pressing "ON/OFF", "Reset' or any button of "Hold time". The sensor settings are changed accordingly.
*Test mode defaulted settings
Daylight sensor=disable
Hold time=3s
Twilight time=N/A
Twilight level=N/A
In this mode, when used for on/off control, after motion detected, sensor enters into a cycle of 3s on and 2s off. In this mode, when used for tri-level dimming control, after motion detected, sensor enters into a cycle of 3s on and 2s off(0.5s soft off + 1.5s off).
5V/12V DC Input Microwave Motion Sensor Highbay Version
DC Input Motion Sensor Module
Highbay DC Input Motion Sensor
HNS111HB
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
Features
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
0~10V DC output signal
Super compact, flexible to be integrated into any suitable fixtures.
Dual ï¹£ PD technology, real Daylight monitoring function for built-in application.
IR remote commissioning, easy setting and user friendly.
Detection range up to 18m in diameter.
Mounting height: 10~12m.
Operation temperature: -20 ~ +70
RoHS compliant.
Settings(Remote control IR12)
Permanent ON/OFF function
Press ON/OFF button, fixture goes to permanent on or permanent off mode, sensor is disabled.
*press "Auto" ,"Reset" or "Ambient learn" to quit this mode.
Dim +/-
Press "Dim" button to automatically dim up or down the light brightness during hold-time from 10% to 100%. Another press to lock it down when desired brightness is achieved.
*after desired brightness is locked down, if user wants to dim again reversely, just press the Dim button again and then lock down the new brightness again.
Sensor mode
Press "Auto" button, the sensor starts to work and all settings remain the same as the latest status before the light was switched on/off.
Reset function
Press "Reset" button, all settings go back to factory default settings.
Factory default settings
Sensitivity=100%
Daylight sensor=disable
Hold time=90s
Twilight time=5min
Twilight level=10%
Ambient learn
Press "Ambient learn" button, the latest surrounding lux value overwrites previous lux value learned, and set as the daylight threshold. This feature enables the fixture to function well in any real application circumstance.
Test mode
"Test mode" is for testing purpose only, for users to check the functionality and choose the desired detection range. The sensor goes to test mode automatically after pressing this button.
Users can quit this mode by pressing "ON/OFF", "Reset' or any button of "Hold time". The sensor settings are changed accordingly.
*Test mode defaulted settings
Daylight sensor=disable
Hold time=3s
Twilight time=N/A
Twilight level=N/A
In this mode, when used for on/off control, after motion detected, sensor enters into a cycle of 3s on and 2s off. In this mode, when used for tri-level dimming control, after motion detected, sensor enters into a cycle of 3s on and 2s off(0.5s soft off + 1.5s off).
AC Input Microwave Motion Sensor - Highbay Version
AC Input Microwave Motion Sensors
Microwave Motion Sensors AC Input
HNS203HB
5.8GHz C-band microwave motion sensor, tri-level dimming control.
Operating voltage: 120~277V AC, 50/60Hz.
Rated load: 400W @ 120VAC, (capacitive)
Features
5.8GHz C-band microwave motion sensor, tri-level dimming control.
Operating voltage: 120~277V AC, 50/60Hz.
Rated load: 400W @ 120VAC, (capacitive)
800W @ 200~277VAC, (capacitive)
Stand-by power: 1w.
Dual-PD technology, real Daylight monitoring function for built-in application.
Zero-cross point operation, protect the sensor relay against the in-rush current, secure the max. load and life time of the relay .
Detection range up to 18m in diameter.
Mounting height: 10~12m.
Operation temperature:-20??+70??
RoHS compliant.
IP rating: IP20.
Setting
Detection range
Detection range can be reduced by selecting the combination on the DIP switches to fit precisely each application.
Hold-time
Hold-time means the time period to keep the lamp on 100% after motion detected.
*when hold-time set as 3s, sensor enters into test mode, this test mode is mainly for users to choose the desired detection range.
In this mode, the daylight sensor is disabled, when there is no motion, fixture keeps off, when there is motion detected, fixture keeps a cycle of 3s on and 2s off.
Daylight sensor
Daylight sensor means the daylight threshold to enable or disable the sensor function.
"Disable": The sensor works always, even during daylight.
"50lux": The sensor works only in twilight.
"10lux, 2lux": The sensor works only in the dark.
Stand-by period
This is the time period that the lamp remains at a low light level before it is completely switched off in the long absence of people.
"+" : means bi-level dimming control, the fixture never switch off.
Stand-by dimming level
This is the dimmed low light level you would like to have after the hold-time in the absence of people.
*0% means on/off control.
10%--Vdim=1.5Vdc 30%--Vdim=3.0Vdc50%--Vdim=5.0Vdc
Remote Control DC Input Motion Sensor
Motion Sensor Module DC Input
5V/12V DC Input Microwave Motion Sensor ?? Remote Controllable Version
HNS112
5.8GHz C-band microwave, tri-level dimming control.
Input voltage 12V DC (5V & 24V DC version available on request).
Features
5.8GHz C-band microwave, tri-level dimming control.
Input voltage 12V DC (5V & 24V DC version available on request).
0~10V DC output signal.
Super compact, flexible to be integrated into any suitable fixtures.
Dual-PD technology, real Daylight monitoring function for built-in application.
IR remote commissioning, easy setting and user friendly.
Detection range up to 12m in diameter.
Mounting height: 3~6m.
RoHS compliant.
Settings(Remote control IR12)
Permanent ON/OFF function
Press ??ON/OFF?? button, fixture goes to permanent on or permanent off mode, sensor is disabled.
*press "Auto" ,"Reset" or "Ambient learn" to quit this mode.
Dim +/-
Press "Dim" button to automatically dim up or down the light brightness during hold-time from 10% to 100%. Another press to lock it down when desired brightness is achieved.
*after desired brightness is locked down, if user wants to dim again reversely, just press the ??Dim?? button again and then lock down the new brightness again.
Sensor mode
Press "Auto" button, the sensor starts to work and all settings remain the same as the latest status before the light was switched on/off.
Reset function
Press "Reset" button, all settings go back to factory default settings.
Factory default settings
Sensitivity=100%
Daylight sensor=disable
Hold time=90s
Twilight time=5min
Twilight level=10%
Ambient learn
Press "Ambient learn" button, the latest surrounding lux value overwrites previous lux value learned, and set as the daylight threshold. This feature enables the fixture to function well in any real application circumstance.
Test mode
"Test mode" is for testing purpose only, for users to check the functionality and choose the desired detection range. The sensor goes to test mode automatically after pressing this button.
Users can quit this mode by pressing "ON/OFF", "Reset' or any button of "Hold time". The sensor settings are changed accordingly.
*Test mode defaulted settings??
Daylight sensor=disable
Hold time=3s
Twilight time=N/A
Twilight level=N/A
In this mode, when used for on/off control, after motion detected, sensor enters into a cycle of 3s on and 2s off. In this mode, when used for tri-level dimming control, after motion detected, sensor enters into a cycle of 3s on and 2s off(0.5s soft off + 1.5s off).
5V/12V DC Input Microwave Motion Sensor Highbay Version
DC Input Motion Sensor Module
Highbay DC Input Motion Sensor
HNS111HB
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Features
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
0~10V DC output signal
Super compact, flexible to be integrated into any suitable fixtures.
Dual ï¹£ PD technolo gy, real Daylight monitoring function for built-in application.
IR remote commissioning, easy setting and user friendly.
Detection range up to 18m in diameter.
Mounting height: 10~1 2m.
Operation temperatur e: -2 ~ +70
RoHS compliant.
Settings(Remote control IR12)
Permanent ON/OFF function
Press ON/OFF button, fixture goes to permanent on or permanent off mode, sensor is disabled.
*press "Auto" ,"Reset" or "Ambient learn" to quit this mode.
Dim +/-
Press "Dim" button to automatically dim up or down the light brightness during hold-time from 10% to 100%. Another press to lock it down when desired brightness is achieved.
*after desired brightness is locked down, if user wants to dim again reversely, just press the Dim button again and then lock down the new brightness again.
Sensor mode
Press "Auto" button, the sensor starts to work and all settings remain the same as the latest status before the light was switched on/off.
Reset function
Press "Reset" button, all settings go back to factory default settings.
Factory default settings
Sensitivity=100%
Daylight sensor=disable
Hold time=90s
Twilight time=5min
Twilight level=10%
Ambient learn
Press "Ambient learn" button, the latest surrounding lux value overwrites previous lux value learned, and set as the daylight threshold. This feature enables the fixture to function well in any real application circumstance.
Test mode
"Test mode" is for testing purpose only, for users to check the functionality and choose the desired detection range. The sensor goes to test mode automatically after pressing this button.
Users can quit this mode by pressing "ON/OFF", "Reset' or any button of "Hold time". The sensor settings are changed accordingly.
*Test mode defaulted settings
Daylight sensor=disable
Hold time=3s
Twilight time=N/A
Twilight level=N/A
In this mode, when used for on/off control, after motion detected, sensor enters into a cycle of 3s on and 2s off. In this mode, when used for tri-level dimming control, after motion detected, sensor enters into a cycle of 3s on and 2s off(0.5s soft off + 1.5s off).