Please click here to check who's online and chat with them.

Sending Inquiry For: Remote Control Dc Input Motion Sensor

Jul-24-18
5V/12V DC Input Microwave Motion Sensor Remote Controllable Version
Remote Control DC Input Motion Sensor
Motion Sensor Module DC Input
HNS111
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
Features
5.8GHz C-band microwave.
Input voltage 12V DC (5V & 24V DC version available on request).
Input current:25mA.
5V DC high-low voltage & PWM output signal(0~10v version available on request)
Super compact, flexible to be integrated into any suitable fixtures.
Dual - PD technology, real Lux -Off & Daylight monitoring function for built-in application.
IR remote commissioning, easy setting and user friendly.
Detection range up to 12m in diameter.
Mounting height: 3~6m.
Operation temperature: -20 ~ +70
RoHS compliant.
Settings(Remote control IR12)
Permanent ON/OFF function
Press ON/OFF button, fixture goes to permanent on or permanent off mode, sensor is disabled.
*press "Auto" ,"Reset" or "Ambient learn" to quit this mode.
Dim +/-
Press "Dim" button to automatically dim up or down the light brightness during hold-time from 10% to 100%. Another press to lock it down when desired brightness is achieved.
*after desired brightness is locked down, if user wants to dim again reversely, just press the Dim button again and then lock down the new brightness again.
Sensor mode
Press "Auto" button, the sensor starts to work and all settings remain the same as the latest status before the light was switched on/off.
Reset function
Press "Reset" button, all settings go back to factory default settings.
Factory default settings Sensitivity=100%
Daylight sensor=disable
Hold time=90s
Twilight time=5min
Twilight level=10%
Ambient learn
Press "Ambient learn" button, the latest surrounding lux value overwrites previous lux value learned, and set as the daylight threshold. This feature enables the fixture to function well in any real application circumstance.
Test mode
"Test mode" is for testing purpose only, for users to check the functionality and choose the desired detection range. The sensor goes to test mode automatically after pressing this button.
Users can quit this mode by pressing "ON/OFF", "Reset' or any button of "Hold time". The sensor settings are changed accordingly.
*Test mode defaulted settings
Daylight sensor=disable
Hold time=3s
Twilight time=N/A
Twilight level=N/A
In this mode, when used for on/off control, after motion detected, sensor enters into a cycle of 3s on and 2s off. In this mode, when used for tri-level dimming control, after motion detected, sensor enters into a cycle of 3s on and 2s off(0.5s soft off + 1.5s off).

-