Dc resistancetest around group is an indispensable test project of transformer after the submission of pick up overhaul and change of subpick up switch. In general using traditional methods (bridge method and pressure drop method) measurement transformer winding group and dc resistance of large power inductance equipment is a time-consuming and time-consuming work. In order to change this situation shorten measurement time and reduce work burden of test personnel, our company developed Dc resistance rapid test instrument (hereinafter referred to as direct resistance instrument). It adopts new power supply technology featuring stable performance rapid measurement small size easy to use high measurement precision and good data repeatability. Measurement transformer is around the group and large power inductor dc resistance ideal equipment product names Dc resistance tachometer Transformer dc resistance test instrument. Transformer winding dc resistance test instrument. Transformer direct resistance speed meter Transformer direct resistance quick test instrument Inductive load Dc resistance tachometer Inductive load dc resistance rapid test instrument Inductive load dc resistance test instrument Dc resistance tester
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
Muskaan Power Infrastructure Ltd is one of leading electrical and power equipment's Firm. We are top manufacturer, supplier, exporter of power compact substation transformer, unitize substation transformer, package substation transformer with an exclusive services in India. we are fully assembled, wired and operationally tested in our workshops,We makesure that original quality and condition of products is maintained. � we designed our transformers and available in the market at a valuable cost. Please feel free to contact us any time if you have any inquiry regarding our products.
Muskaan Power Infrastructure Ltd is one of leading electrical and power equipment's Firm. We are top manufacturer, supplier, exporter of power compact substation transformer, unitize substation transformer, package substation transformer with an exclusive services in India. we are fully assembled, wired and operationally tested in our workshops,We makesure that original quality and condition of products is maintained. � we designed our transformers and available in the market at a valuable cost. Please feel free to contact us any time if you have any inquiry regarding our products.
product brief introduction AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance and light weight. 3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive. 4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
product brief introduction Product Introduction The test transformer calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance, and light weight. 3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive. 4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
Product Introduction TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer. The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc. product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester
Three-phase transformers are used to convert the available 3-phase mains voltage into any load voltage. To cater for the wide range of application areas involved,these transformers are essentially available in the same kinds of designs as the single-phase transformers, e.g. Three-phase dry-type transformer: separate winding version Three-phase series transformer: autotransformer winding version Three-phase safety, isolating, mains or insulating transformer: separate winding version In terms of how the 3 coils are connected, there are various options available and each of these provides the transformers with specific properties. The vector group code is composed of the following elements: The upper-case letter indicates the higher-voltage winding (the highest voltage in terms of operation). The lower-case letter indicates the lower-voltage winding. The brought-out neutral is indicated by means of N or n (depending on voltage level). â?¢ The distinctive number indicates the phase angle of the lower voltage in relation to the higher voltage (distinctive number multiplied by 30). The following winding connection options are available Delta: D, d Wye (or star): Y, y Zigzag: Z, z Example: Dyn5 Higher-voltage winding is delta-connected. Lower-voltage winding is star-connected with a brought-out neutral. The lower voltage lags behind the higher voltage by 150�° (5 x 30�°). Unless specifically requested otherwise, the transformers are configured with a double-star connection and a brought-out neutral (vector group Yyn0); for autotransformers the vector group is YNa0. Our three-phase transformer range includes all our standardised types for the 25 30.0 kVA performance range and a frequency of 50/60 Hz
Transformer, High Current Transformer, Ultra Isolation Transformer, Three Phase to Single phase transformer, Control Transformer, furnace Transformers, Special purpose transformers, Electroplating Rectifiers, Reactors, D.C.C.T. etc
Features: Wide range of system current Ratings Hinged terminal cover Various mounting options like DIN rail mounting, Wall mounting Terminal with self lifting screw with dual connection facility giving access from both sides of transformers
Hebei Anmei produce kinds of DIN standard , ANSI standard , AS standard transformer bushing insulator, oil level gauge and transformer accessorise
Used transformers
Used transformers
Product Details It is the insulating sleeve that leads the transformer's internal high and low voltage leads to the outside of the oil tank, which not only insulates the ground as the lead, but also plays the role of fixing the lead. Therefore, the transformer sleeve has the following requirements: (1) it must have specified electrical strength and sufficient mechanical strength. (2) must have good thermal stability, and can withstand the short circuit of the instant overheating. (3) small appearance, small quality, good sealing performance, strong universality and easy maintenance folding.
Transformer bushing insulators are applied as a structure, carrying on conductor through a partition such as transformer tank and insulating it, incorporating the means of attached flange to the partition for medium voltage level. For Entire Range of Bushings Ratings from - 1 Kv to 72 Kv & - 100 Amp. to 10,000 Amp. All Ares Insulator transformer bushing insulators are made of ceramic materials according to IEC 672. Other Transformer bushing custom-made insulators can be supplied upon customer's request and specifications.
Toroidal magnetic cores are made of a Fe-based thin (20 microns) nanocrystalline ribbon and have low loss, high induction of saturation, high operating temperature (up to 150 C), high magnetic permeability. Magnetic cores have a negative temperature coefficient of losses that provides stabilization mode transformer temperature. Application in power high- frequency transformers push-pull,bicyclic SMPS, DC-DC converters, audiotransformers. High permeability provides good electromagnetic connection of windings and low leakage inductance values. HIGHLIGHTS OF THE MATERIAL: Induction amplitude, Bm (25 C) 1,2 T Induction amplitude, Bm (90 C) 1,1 T Curie temperature, Tc 570 C Magnetostriction less than 0,5 x10 ^ -6 Magnetic Permeability (100 kHz) - up to 20,000
Co-based amorphous core in plastic container 1. high permeability 2.Thickness (1820 mkm) 3. Annealing in transverse field, permeability more than 100000, very low loss, flat hysteresis loop 4. Common-mode filter chokes, current transformers, including for precise electronic electricity meters, protective cutout, High Frequency power transformers in SMPS, audio transformers, etc. 5.D from 4-32mm Ribbon wound magnetic core is placed into hard protective container of glass-polyamide and mechanically fixed with silicone sealant. Co-based amorphous ribbon wound magnetic core is placed into hard protective container of glass-polyamide and mechanically fixed with silicone sealant.Size veries:outer D =4-32mm.The container has rounded edges and is designed for direct winding of a thick wire. The container provides reliable mechanical protection and preservation of amorphous material's properties. All materials comply with UL94V-1 / 0. 1. High permeability 2.Thickness (1820 mkm) 3. Annealing in transverse field, permeability more than 100000, very low loss, flat hysteresis loop 4. KEY FEATURES OF THE AMORPHOUS MATERIAL: Induction amplitude, Bm (25C) 0.59 T Induction amplitude, Bm (90C) 0.50 T Curie temperature, Tc 220C Operating temperature range -60C ... 100C Magnetostriction less than 0.110^-6 Typical permeability (10 kHz) - 120 000 Typical permeability (100 kHz) - 35 000
Co-based amorphous core in plastic container 1. high permeability 2.Thickness (18-20 mkm) 3. Annealing in transverse field, permeability more than 100000, very low loss, flat hysteresis loop 4. Application: Common-mode filter chokes, current transformers, including for precise electronic electricity meters, protective cutout, High Frequency power transformers in SMPS, audio transformers, etc. KEY FEATURES OF THE AMORPHOUS MATERIAL: Induction amplitude, Bm(25C) 0.62 T Induction amplitude, Bm(90C) 0.54 T Squareness ratio Br/Bm (@ 100 kHz, 80 A/m) at least 0.90 Curie temperature, Tc 225C Operating temperature range -60C ... +100C Magnetostriction less than 0.110^-6