Eltek 242100.111 Smartpack RS-232 front SMARTPACK CONTROLLER MONITORING AND CONTROL UNIT 242100.110 Smartpack Extended (6 + 6 I/O, 2 String Battery connection) 242100.111 Smartpack RS-232 front (RS-232, 6 + 6 I/O, 2 String Battery connection) 242100.118 Smartpack WEB/SNMP (Ethernet, 6 + 6 I/O, 1 String Battery connection) 242100.000 Smartpack Basic Slave (without display, buttons & internal power for distributed systems) 242100.300 Battery Monitor 242100.301 Load Monitor 242100.304 I/O Monitor (Outdoor) 242100.200 Smartnode RS232/485
ELTEK Smartpack Extended 242100.110 242100.110 Smartpack Extended (6 + 6 I/O, 2 String Battery connection) 242100.111 Smartpack RS-232 front (RS-232, 6 + 6 I/O, 2 String Battery connection) 242100.118 Smartpack WEB/SNMP (Ethernet, 6 + 6 I/O, 1 String Battery connection) 242100.000 Smartpack Basic Slave (without display, buttons & internal power for distributed systems)
Flatpack S 24V RECTIFIER 1000W SIL3 OVP ELTEK Flatpack S 24/1000 SIL3 OVP
Eltek Micropack 48V/250W Rectifier 241120.100 Eltek Micropack System is convection cooled, designed for less power-hungry applications, but still with system functionality options to match any requirements. Use as stand-alone or in a flexible off-the-shelf configurable system. Eltek Micropack Power System extends your network one step further. With load ranges typically between 120W and 1000W, and in 12V, 24V, and 48V options, the system is perfect for a great variety of applications.
Eltek Micropack Rectifiers 24V/240W 241120.200 The Micropack System is convection cooled, designed for less power-hungry applications, but still with system functionality options to match any requirements. Use as stand-alone or in a flexible off-the-shelf configurable system. The Micropack Power System extends your network one step further. With load ranges typically between 120W and 1000W, and in 12, 24, and 48V options, the system is perfect for a great variety of applications.
Eltek Micropack Rectifiers 12V/120W 241120.300 INPUT DATA Voltage range 85 - 300 VAC/DC 1) Voltage range (nominal) 130 - 275 VAC/DC 185 - 275 VAC/DC 1) Frequency 0 - 66 Hz 1) Maximum current, 230V input / overall (boost) 0.6 A / 2.0 A 1.2 A / 2.0 A 1.2 A / 1.9 A Maximum earth leakage current 2.0 mA (@ 250VAC/50Hz) Power Factor 0.97 (@ 70 - 100 % load) 0.98 (@ 55 - 100 % load) 0.98 (@ 50 - 100 % load) THD (@ 230 VAC) < 5 % (@ 80 - 100 % load) < 5 % (@ 50 - 100 % load) < 5 % (@ 50 - 100 % load) Protection Varistor for transient protection, fuse in both lines (2x 2.0 A), shutdown above 300 VAC/DC OUTPUT DATA Default voltage 13.6 VDC 27.2 VDC 53.5 VDC Voltage range 10.7 - 18.0 VDC 21.5 - 36 VDC 43.5 - 57.6 VDC Voltage range without controller 10.7 - 15.0 VDC 21.5 - 30 VDC 43.5 - 57.6 VDC # Pb cell supported (1.8 - 2.4 VDC/cell) 6 - 7 12 - 15 24 # NiCad cell supported (1.05 - 1.65 VDC/cell) 10 - 112) 20 - 222) - Max power, nominal / 60s boost 120 W / 160 W 240 W / 315 W 250 W / - Max current, @12/24/48VDC / boost / QT3) 10 A / 15 A / 55 A 10 A / 15 A / 55 A 5 A / - / - Current sharing �±5% of maximum current from 10 to 100% load Static voltage regulation �±0.5% from 10% to 100% load and nominal input Dynamic voltage regulation �± 5 % < 10ms, load step 10% to 90% or opposite at nominal output voltage Hold-up time, default voltage and full power 20 ms, VOUT > 10.7 VDC 20 ms, VOUT > 21.5 VDC 20 ms, VOUT > 43 VDC Rippel and noise, 30 MHz b.w. / psophometric < 200 mVPP / 5 mVRMS < 200 mVPP / 5 mVRMS < 150 mVPP / 2 mVRMS Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting, fuse
36/1000 HE UI ELTEK Flatpack S rectifier 36/1000 HE UI 241122.235 INPUT DATA Voltage (nominal) 185 - 400 VDC / 185 - 275 VAC Voltage (operating range) 85 - 400 VDC / 85 - 305 VAC Frequency DC, 16 2/3 Hz, 45 - 66 Hz Current (maximum) 5.9 ADC / 5.9 ARMS Protection Fuse in Positive & Negative, Reversed polarity insensitive, Shutdown above 420 VDC / 305 VAC OUTPUT DATA Voltage 40 VDC Voltage (adjustable range) 331) - 45 VDC Power (maximum) @ nominal input 1000 W / 450 W @16 2/3 Hz input Power (maximum) @ 85 VDC / 85 VAC input 440 W / 440 W Current (max cont.) @ nominal input 27.8 A (@VOUT < 36 VDC) Hold up time, maximum output power >10ms; output voltage > 33 VDC Current sharing (10 - 100% load) �±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) �±0.5% Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Ripple < 150 mVPP , 30 MHz bandwidth Protection ORing FET Short circuit proof High-temperature protection Overvoltage Shutdown
Flatpack2 380/3000 HE UI 380V Rectifier 241119.825 HE rectifier for 380VDC in data centers The Flatpack2 380/3000 HE UI rectifier has high efficiency, ORing protection on output, and high output power. Distribute pure battery backup DC voltage with a minimum of loss. Remove the low reliable DC-AC step in the central backup power system and maximize its reliability and efficiency. Stack cabinets with up to 72 rectifiers to build large power systems monitored by the Smartpack2 controller. The rectifier's Universal Input also allows it to be powered from the 380Vdc bus. Static voltage outputs (300-400Vdc) can be realized for 400Vdc remote powering and other applications.
ELTEK Smartpack R CONTROLLER 242100.120 Retrofit controller Future fit power. It is a simple idea with tremendous effect: Replace your old first-generation Smartpack controller with the Smartpack R to make your power system ready for a high-speed, high-capacity, and connected tomorrow. This retrofit will bring your existing power system in line with current requirements, prolong its lifetime and thereby reduce both the lifetime operating costs and the need for new investments in power.
ELTEK Flatpack S 36/1000 HE UI rectifier Applications in these markets demand state-of-the-art, reliable, and safe DC power systems. Flatpack S delivers an industry-leading power density in its segment, many safety functions, a wide operating temperature range, and superb reliability in its small 217mm deep housing. Used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.
ELTEK Flatpack2 HVDC/DC Converter DCDC 380/48 3000 SHE INPUT DATA Voltage (nominal) 381 VDC Voltage (operating range) 260 - 400 VDC Maximum current 12.3 ADC Protection Fuse, shutdown when VIN is out of range OUTPUT DATA Voltage (default) 54.5 VDC Voltage (adjustable range) 50 - 55 VDC Max power, nominal input 3000 W Max current, @VOUT = 50 VDC 60 A Current sharing �±5% of maximum current from 10 to 100% load Static voltage regulation �±0.5% from 0 - 100% load and nominal input Dynamic voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Ripple < 150 mVPP , 30 MHz bandwidth Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting, OR-ing FET
ELTEK FLATPACK2 48V/3000W HE Rectifier Module 241119.903 INPUT DATA Voltage (nominal) 176 - 275 VAC Voltage (operating range) 85 - 300 VAC Frequency 45 - 66 Hz Current (maximum) 19 ARMS Power Factor > 0.99 at 50-100% load Protection Fuse in L & N, Varistor, Shutdown above 300 VAC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.2 - 57.6 VDC Power @ 230 VAC 3000 W Power @ 85 VAC 1380 W Current 62.5 A (@ 48 VDC) Current sharing (10 - 100% load) �±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) �±0.5% Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time, 1500 W / 3000 W output power >20ms / >10ms ; output voltage > 43 VDC Ripple < 150 mV peak to peak, 30 MHz bandwidth Protection Fuse, Short circuit proof, High temperature protection, Overvoltage shutdown, Hot plug-in inrush current limiting
ELTEK Flatpack2 24/1800 HE 24V Rectifier
ELTEK Flatpack2 60/3000 SHE 60V Rectifier Module INPUT DATA Voltage (nominal range) 206 - 264 VAC Voltage (operating range) 85 - 264 VAC Frequency 45 - 66 Hz Maximum current 16 ARMS Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range OUTPUT DATA Voltage (default) 67 VDC Voltage (adjustable range) 54 - 72 VDC Max power, nominal input 3000 W Max power, de-rated @VIN = 85 VAC 1000 W Max current, @VOUT = 60 VDC 50 A Current sharing �±5.0% of max current Static voltage regulation (10-100% load) �±0.5% Dynamic voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time (3000W load) >10ms; output voltage > 52.5 VDC Ripple < 150 mVPP , 30 MHz bandwidth Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting, fuse
ELTEK FLATPACK S 2U HIGH-EFFICIENCY DC POWER SYSTEM The Eltek Flatpack S 2U system is a high-efficiency power solution with an optimal footprint for up to 200A applications where space is limited â?? both in racks and various cabinet installations. The Flatpack S 2U is a two rack-unit high system that delivers 24V and 48V DC power to telecom infrastructure that includes: 4G/LTE, FTTX, distributed antenna systems (DAS), microwave broadband, cable broadband, telephony servers and switches, and fiber-optics. RECTIFIER PART NUMBERS (SOLD SEPARATELY) 241122.105.VC Flatpack S 48/1000 HE with CLEI 241122.125.VC Flatpack S 48/1800 HE with CLEI 241122.205 Flatpack S 24/1000 HE 241122.930 Flatpack S Blind Panel
Flatpack2, 2U Integrated DC Power supply system, 150A Eltek Flatpack2 2U Integrated has been specifically designed to meet the demand for higher density and more compact power solutions. It is suitable for applications needing an expandable, easily serviceable, and reliable power supply, fitting within a minimal space.
Eltek Flatpack2 48/3000 SHE 241119.106 The Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market. With an efficiency of 97.8%, the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid-connected applications, the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster. The Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module.
Flatpack2 48V SHE Rectifiers Flatpack2 48V Super HE 48/2000 SHE Eltek Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market. With an efficiency of 97.8%, the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid-connected applications, the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster. Eltek Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module.
Eltek Scalable System 54kVA MODEL 72 KW Part number CTER3642.xxxx INPUT DATA Voltage range AC (3 phase Y) 320-475 V Voltage range DC 40-58 V Maximum current AC (per phase) 84-144 A Frequency 50 Hz / 60 Hz Power factor > 0.99 OUTPUT DATA Adjustable range AC (3 phase Y) 346-415 V Adjustable range DC 43-58 V Max output power AC 54,0 kVA / 43,2 kW Max output power DC 43,2 kW Admissible load power factor 0 Ind. to 0 Cap. Frequency 50 Hz / 60 Hz Battery breaker (1-pole) 2*1600 or 4*600 A OTHER SPECIFICATIONS DC distribution 1 pole, 1-600 A AC Distribution 1-3 pole 2-63 A Manual Bypass Switch Internal LVBD (1-pole) 1800 A
Scalable System 18-72 kVA, single input MODEL 72 KW Part number CTER3642.xxxx INPUT DATA Voltage range AC (3 phase Y) 320-475 V Voltage range DC 40-58 V Maximum current AC (per phase) 84-144 A Frequency 50 Hz / 60 Hz Power factor > 0.99 OUTPUT DATA Adjustable range AC (3 phase Y) 346-415 V Adjustable range DC 43-58 V Max output power AC 54,0 kVA / 43,2 kW Max output power DC 43,2 kW Admissible load power factor 0 Ind. to 0 Cap. Frequency 50 Hz / 60 Hz Battery breaker (1-pole) 2*1600 or 4*600 A OTHER SPECIFICATIONS DC distribution 1 pole, 1-600 A AC Distribution 1-3 pole 2-63 A Manual Bypass Switch Internal LVBD (1-pole) 1800 A