ELTEK Flatpack2 HVDC/DC Converter DCDC 380/48 3000 SHE
INPUT DATA
Voltage (nominal) 381 VDC
Voltage (operating range) 260 - 400 VDC
Maximum current 12.3 ADC
Protection Fuse, shutdown when VIN is out of range
OUTPUT DATA
Voltage (default) 54.5 VDC
Voltage (adjustable range) 50 - 55 VDC
Max power, nominal input 3000 W
Max current, @VOUT = 50 VDC 60 A
Current sharing �±5% of maximum current from 10 to 100% load
Static voltage regulation �±0.5% from 0 - 100% load and nominal input
Dynamic voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Ripple < 150 mVPP , 30 MHz bandwidth
Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug-in
inrush current limiting, OR-ing FET
Eltek Flatpack2 48/3000 SHE 241119.106 The Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market. With an efficiency of 97.8%, the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid-connected applications, the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster. The Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module.
Flatpack2 48V SHE Rectifiers Flatpack2 48V Super HE 48/2000 SHE Eltek Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market. With an efficiency of 97.8%, the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid-connected applications, the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster. Eltek Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module.
Flatpack2 380/3000 HE UI 380V Rectifier 241119.825 HE rectifier for 380VDC in data centers The Flatpack2 380/3000 HE UI rectifier has high efficiency, ORing protection on output, and high output power. Distribute pure battery backup DC voltage with a minimum of loss. Remove the low reliable DC-AC step in the central backup power system and maximize its reliability and efficiency. Stack cabinets with up to 72 rectifiers to build large power systems monitored by the Smartpack2 controller. The rectifier's Universal Input also allows it to be powered from the 380Vdc bus. Static voltage outputs (300-400Vdc) can be realized for 400Vdc remote powering and other applications.
Flatpack2 380V Rectifier Doc 241119.825.DS3 v4 Model Flatpack2 380/3000 HE (UI) Part number 241119.825 INPUT DATA Voltage (nominal) 176 - 277 VAC / 260 - 400 VDC1) Voltage (range) 85 - 305 VAC / 260 - 410 VDC1) Frequency 45 - 66 Hz / 15 - 18.5 Hz2) / DC1) Current (maximum) @ nominal input, full load 18.2 ARMS Power Factor > 0.99 at 50% load or more Protection Fuse in L & N Varistor Disconnect when VIN is out of range OUTPUT DATA Voltage (default) 381 VDC Voltage (adjustable range) 300 - 400 VDC # Pb cell supported 156 - 168 3) Power continuous (maximum) 3000 W Power @ 85 VAC / 85 VDC 1200 W Current continuous (maximum) 9 A (@VOUT < 336 VDC) / 7.9 A (@ VOUT = 381 VDC) Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) ±0.5% Dynamic Voltage regulation ±2.0% for 10-90% or 90-10% load variation, regulation time < 10 ms 5) Hold up time > 20 ms; output voltage > 300 VDC at 1500 W load Ripple < 1000 mVP-P , 30 MHz bandwidth Protection Overvoltage shutdown, Hot plug-in - Inrush current limiting, ORing diode, Fuse5), Short circuit proof, High temperature protection, Overload shutdown4) OTHER SPECIFICATIONS Efficiency @ 230 VAC / 380VDC input 96.2% / 96.6% Isolation 3.0 kVAC input to output, 1.5 kVAC input to earth, 1.5 kVDC output to earth, 3.0 kVAC CAN to primary, 3.0 kVAC CAN to secondary Alarms (Red LED) Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings (Yellow LED) Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (Green LED) Input and output ok Acoustic noise, at nominal input and full load < 40dBA @Tambient< 25C / 40C MTBF (Telcordia SR-232 Iss.3 Meth. II Case L1) 2 291 210h (@ Tambient = 25 C) Operating temperature -40 to +75C (-40 to +167F), humidity 5 - 95% RH non-condensing Output power de-rates linear from 3000W @ 50C (122F) to 980W @ 7C(167F) Storage temperature -40 to +85C (-40 to +185F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327 mm (4.25 x 1.69 x 13) / < 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013, UL 60950-1:2014, CSA C22.2 No. 60950-1-07 EMC EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010, IEC61000-6-5: 2015, EN 300 386:v1.6.1, FCC CFR 47 Part 15:2013 Environment Tested according to: ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE)
Top Quality Compressor Scrap Used Electric Motor scrap AC Compressor Scrap Drained Copper Compressor â?? Fridges/AC (RAINS per ISRI Specifications). Our copper content on 99.97 % Monthly Supply Capacity: 500 - 1500 metric tons, Type: Fridges, AC. Packaging Detail: Wood Pallets, 20(40) FCL/ According to ISRI Specification in Containers Quantity: Between 200~500MT per month Minimum Order acceptable 1x20FCL (25MT or 26MT/20FCL, 3000 or 3450 Pieces/20FCL Detailed Specifications : Compressor Brands : Necchi, Danfoss, Aspera, Ireland, Embraco Compressor Weight : 2kg, 4kg, 6kg, 8kg, 10kg, and 12kg More Details : 220-240 v 50 or 60 hz. Cooling capacity: 90-190 w displ Size : 5.99 -12.53 cm3 Purity: 99.98% copper inside with connection box Send your message to this supplier Main Specification:
ELTEK Flatpack2 60/3000 SHE 60V Rectifier Module INPUT DATA Voltage (nominal range) 206 - 264 VAC Voltage (operating range) 85 - 264 VAC Frequency 45 - 66 Hz Maximum current 16 ARMS Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range OUTPUT DATA Voltage (default) 67 VDC Voltage (adjustable range) 54 - 72 VDC Max power, nominal input 3000 W Max power, de-rated @VIN = 85 VAC 1000 W Max current, @VOUT = 60 VDC 50 A Current sharing �±5.0% of max current Static voltage regulation (10-100% load) �±0.5% Dynamic voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time (3000W load) >10ms; output voltage > 52.5 VDC Ripple < 150 mVPP , 30 MHz bandwidth Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting, fuse
This Atmospheric Water Generator is a state-of-the-art water generating Appliance using the latest technology available to the industry. EcoloBlue designed your Atmospheric Water Generator with one objective in mind: produce the maximum amount of high quality drinking water using only a minimum amount of electricity. In addition to atmospheric water production, the Appliance can also be used as a conventional water purifier by connecting it to an external municipal (city) water source.
Original Rectifier Module Flatpack2 48/2000 HE