The photoconductive rod of 360 degrees rotation can avoid infection with high temperature. 1100mw/cm2 of its light intensity. It needs just 10s to solidify the 4mm materials. The wavelength range is from 420nm to 480nm, which can solidify all presently photosensitive material. Use the rechargeable li-ion battery. The total operation times from 20s x 250 times Superconductor will radiate more than 100.000 times for several years without changing the bulbs. Made of aluminum alloy frames with extremely light weight, only 150g. Quiet design without the fans and with the cold light source. Can choose the different color. Technical parameters Handpiece dimensions23x155mm Gradeworing by fits Light intensity>800mw/cm2 Wavelength range420nm-480nm Time to recharge4hr Mode+10/20sec.By modes Rechargeable li-ion battery1300mah Handpiece weight150g Input power100-240vac, 50/60hz
Ve producer in china adopting the fifth generation circuit in the area of apex locator, based on the multi-frequency closed circuit human body's oral cavity. Free from the conditions of root-canal Dryness or electrolytes, blood or physiological brines will not affect the measuring result The narrow area (apical constriction) of the apex in the following figure of root-canal can be adjusted by the dentists if necessary (range 0-5mm). Autoclavable accessories to avoid cross infection Equipped with self-check circuit to guarantee the accuracy by adjusting the program data beforehand! Compact, stable, ergonomic design for easy handling Colored lcd screen and piezoelectric buzzer: Lithium battery-operated Specifications A. Power voltage: dc7.5v B. Power consumption: below 0.04w C. Current:
Endo motor Convenient to operate Finding the apex and root canal treatment can be operated separately or simultaneously (also called full automation). Adjustable speed 5 settings for adjustable rotational speed ranging from 125 to 625rpm Drive-1:1 control angle is available! The torque exceeds the regulated value, the file will reverse to avoid the break-off during the working status of full automation. Easy operating with lcd screen-what you see, what you get Build-in rechargeable battery, specifically designed for patient comfort Fully guaranteed for one year 1. Voltage: dc8.8v 2. Current:
Apex locator Exclusive producer in china adopting the fifth generation circuit in the area of apex locator, based on the multi-frequency closed circuit human body's oral cavity. Free from the conditions of root-canal Dryness or electrolytes, blood or physiological brines will not affect the measuring result The narrow area (apical constriction) of the apex in the following figure of root-canal can be adjusted by the dentists if necessary (range 0-5mm). Autoclavable accessories to avoid cross infection Equipped with self-check circuit to guarantee the accuracy by adjusting the program data beforehand! Compact, stable, ergonomic design for easy handling Colored lcd screen and piezoelectric buzzer: Lithium battery-operated A. Power voltage: dc7.5v B. Power consumption: below 0.04w C. Current:
Three-point spraying, anti-retraction, quick coupling, large four- hole turbine with push button. Three type head: standard head-series ad; medium head-series az; mini head-series ax, 310000rpm, push botton, 360 degree rotatable quick coupling with build-in anti-retraction system. (2 holes & 4 holes available) Three-point spraying, anti-retraction, quick coupling, large four- hole turbine with push button. Three type head: standard head-series ad; medium head-series az; mini head-series ax, 310000rpm, push botton, 360 degree rotatable quick coupling with build-in anti-retraction system. (2 holes & 4 holes available)
Operation Instructions of USB (Digital) Intraoral Camera 1. Introductions USB-Intra-Cam is the newest hand-held intraoral camera made in China. Its lightweight design and smooth contours make it both comfortable to hold and easy to use. Taking images with the integrated capture button makes video capture a simple one-step operation. And its built-in LED light source provides reliable, long-life illumination. No capture card and external electricity supply are required, therefore, installation and setup is just a snap. 2. Technical Data Image Resolution (Standard/ Luxury) 480K / 1300K Illumination 2-3LUX Frame Rate 15~30fps Focus Range (Standard/ Luxury) 8~12mm/ 6~35mm Interface (Standard/ Luxury) USB1.1/ 2.0 Compatibility Windows XP 3. Requirements of Computer Configuration Getting the best results from USB-Intra-Cam begins with having a computer system suitable for displaying and capturing video images. For optimum performance we recommend: 1) PCs equipped with Pentium III processor or higher. 2) Minimum 8MB video memory. 3) Display values for your monitor set at least to 1024 x 768, 24-bit color. 4) We also recommend using the factory defaults for our Cameras.
Brief introduction: Equal light distribution High intensity Quiet, no noise of a fan 5 tube fluorescent lights Stand, : for the functional placement we offer a stand on castors Integral timer attached to count total hours of usage Height adjustable Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : 120va Wave length (blue light): 425nm~ 275nm Light output: 500µ w/cm² Scope of light tube: 200mm Angle of light tube: 0º~90º Time accuracy: 2h+1min Integral time range: 0h~999h 59min Operation condition: Environment temperature: 18¦~30¦ Environment relative humidity: 10%~85%rh Atmosphere pressure: 700~1060hpa Package Gross weight : 45kg net weight: 25kg Measurement920*740*350mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37 pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40fpc. Humidity is adjustable. The infant bed inclination angle is adjustable. Gross weight : Control cabinet: 120kg hood cabinet: 30kg Net weight: Control cabinet: 90kg hood cabinet: 10kg Measurement 1200*700*960mm
Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Gross weight : 100kg net weight: 70kg Measurement: 1100*700*960mm
Brief introduction: Equal light distribution. High intensity. Quiet, no noise of a fan. 5 tube fluorescent lights. Stand, : for the functional placement we offer a stand on castors. Integral timer attached to count total hours of usage. Height adjustable. Gross weight : 45kg net weight: 25kg Measurement·ª920*740*350mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40pc. Humidity is adjustable. The infant bed inclination angle is adjustable. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _420va Air temperature control range 2538 Temperature fluctuation: _0.5 Uniformity of mattress temperature: _0.8 Warm-up time: _45min Internal noise level: _55db Operation condition: Environment temperature: 2538 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Brief introduction: Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _1500va Temperature control range: 32~38.5 Temperature probe accuracy: _0.3 Mattress temperature uniformity: _2.0 Warm-up time: _45min Adjustable horizon angle of radiator: +90 Operation condition: Environment temperature: 18~30 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Adopt ceramic transducer. Automatic frequency trace. 5 tips. 220v 50hz, 2.1kg.
Controlled time with coms. Wide-scope voltage. Prolong the life of a lamp. 220v 50hz, 1.6kg.
1, human body temperature measurement: accurate measurement of human body temperature, replace the traditional mercury thermometer. Women who want to have children can use infrared thermometer (frontal temperature gun) to monitor basal body temperature at any time, record body temperature during ovulation, and choose the right time to conceive, and measure temperature to determine pregnancy. Of course, the most important thing is to always observe whether your body temperature is abnormal, to avoid influenza infection, and to prevent swine flu. 2. Skin temperature measurement: To measure the surface temperature of the human skin, for example, it can be used to measure the surface temperature of the skin when it is used for re-implantation of a limb. 3. Object temperature measurement: measure the surface temperature of the object, for example, it can be used to measure the temperature of the tea cup. 4, liquid temperature measurement: measure the temperature of the liquid, such as the temperature of the baby's bath water, measure the water temperature when the baby is bathing, no longer worry about cold or hot; you can also measure the water temperature of the milk bottle, easy to prepare Baby's milk powder; 5. Can measure room temperature:
1. cardinal, oth usa , we have usa titleholder channel. 2 china n95 \ kn95 \ ffp3 masks and 3 layer disposable masks, masks, surgical gowns, isolation suits, nitrile gloves), cosmetics, health and beauty, daily necessities, shoes.Import and export, international trade
Features: Parameters: PT, APTT, TT, FIB. Etc Principle: Clotting, optical method Principle: Clotting, optical method Precise electronic pipette Micro sample volume Automatic start at reagent addition Thermal printer, auto&manual print Support LIS Specification Testing channel:        BCA101:1                      BCA102:2                      BCA104:4 Display:              BCA101: 4.3 inch screen                      BCA102/104:5inch screen Cuvette incubation positions:       BCA101:5                              BCA102:12                              BCA104:24 Reagent incubation positions:      BCA101:2                              BCA102:5                              BCA104:6 Wavelength:                   LED470nm Sample type:                   Plasma Memory:                      10,000 results storage Sample volume:                20-40L Reagent volume:               20-40 L Eletronic pipette:               20-200L Avaible dimensions:             Seconds, ratio, %, g/L Incubation temperature:          37±1.0C Relative humidity:               85% Precision:                     PT, APTT,FIB5%;TT8%                              (Normal sample) Divation between channels:       5% Power supply:                 AC 100-240V 50/60Hz BCA101:                  2.1kg BCA102:                  4.5kg BCA104:                  5.2kg
Features Throughput: 60 samples/hour Principle: ISE(Ion Selective Electrode) 5.6-inch color touch screen Auto sampling, washing, calibration Maintenance-free electrodes, 12 months lifespan Simple tubing system, easy maintenance CE marked Technical Specifications Sample type: Serum, etc. Sample volume:100-200L Reagent consumption: 2 times sample volume Calibration: Automatic or On-demand Closed reagent, real time monitoring reagent Printer: Internal thermal printer Display: LCD Multiple language: English, Russian, etc. Storage: Up to 50,000 results Interface: RS-232, support LIS Working temperature:15-30C Humidity: 20%-80% Dimension: 430 27 410mm Power: AC100~240V, 50/60 Hz, 80W Net weight :8 kg Reagent DS-I(NO.3) Standard A Standard B (390/160 mL) Cleaning Solution (250 mL) PVC Electrode Activating Solution PVC Electrode Activating Solution(50 mL) DS- Ref Ref. Filling Solution(10 mL) DS- ISE Filling Solution (10mL) Deprotein Solution (R1: Diluent 18mL/bottle 1; R2: Protease powder 100mg/bottle 6)
The suitcase contain what veterinary teeth cleaning need, and you can choose what you need about the handpieces
160 T/H Full-auto Biochemistry Analyzer Introduction: The equipment is applicable to various hospitals ,hygiene&epidemic stataion etc on Main Features: *New concept and more friendly software *New techniques and spare parts are used for much better quality and function *Automatic washing station for both sample and reagent probe *Liquid level detection and collision protection for both sample and reagent probe *Reliable cooling system for reagent chamber *Powerful reaction cuvette washing system *ISE module and barcode sacnner(optional) *Lower reagent consumption *New concept test control system available(on request) Function: 1.Batch analyzer2.Insert STRT sample at any time during testing.3.Intelligent multi task software . 4.User-friendly software in english, french, spanish, russian versions and other luanage software avaliable on request. 5.Perfect quality control function with Levy-jennings chart and westguard analysis avaliable. 6.Automatic flow cell washing and probe washing between each teat to effectively minimize carry-over. 7.Auto-check and auto-alarm to ensure the analyzer in good condition. 8.New long life pump, no tubing wearing problem any more.Specifications of Auto Biochemistry AnalyzerYJ-160: ModelYJ-160Assay ModelRandom access with direct reading systemAssay Item36 assayThroughput1 Reagent:220 test/h(max);2 Reagent: 160 test/h; With ISE: +100 test/hSample Position50Sample Volume1-100ul,0.1ul/stepReagent Position36Reagent VolumeR1: 1-400ul,1ul/stepR2: 1-400ul,1ul/stepWavetength340-810nmLight sourceHalogen lampMethodEnd point,Kinetic,Fixed time,Immunoturbidimetry,1-2reagen,Mutistandard,reagen/serum blank,etcQuality ControlLevy Jennings quality control program at 3 levelsPrinterMultiple report formats availableFAQï¼? Q:Delivery time:A:3-10 working days after paymentQ:Delivery method:A:Sea shipping, air cargo, Express(DHL/UPS/FEDEX/EMS Service)Q:Payment:A:T/T, L/C, Paypal, Western Union, MoneyGram or negotiable. Q:Warranty:A:We provide 1 year quality assurance for SH-CHEER equipments.Q:Free sample: A:About some medical consumables, we can supply free sample.