Designed for the requirements of the equipment it is widely used in the AC withstand voltage test of the 35-220kV class string-type voltage transformer of the power system to evaluate the main transformer from the insulation strength and also to the winding of the motor and the small transformer. Induction test; can also be used as a short-time 150Hz power supply. 1 the company's Triple frequency transformer is simple to operate reliable performance 2 can well meet the needs of transformers transformers withstand voltage
1. 5 LED digitally display output by actual value or by percentage 2. AC/DC current output range: 0~100 uA ~500uA ~2mA~5mA~20mA ~50mA ~200mA ~500mA ~2A~5A~20A~30A(optional)~50A(optional) 3. AC/DC voltage output range: 0~200mV~1V~2V~5V~10V~20V~50V~100V~200V~500V~1000V 4. Three AC frequencies for option: 50Hz 60 Hz 400 Hz 5. Auto protection or manual resetting function for over load 6. Over load rang is 10% for each level of voltage current 7. Clip-on transformer testing: matching with our product of standard coil measuring range AC 0~750A ( above 1000A for part of meters) DC 0~1000A error: ±0.3%
1. Built-in digital multiple function standard meter with Integrated structure of meter and power source electrical parameters can be read via software 2. adopts DDS technology CPLD and RAM embedded system featured with high stability of signal source output small fineness low distortion 3. RAM system large color LCD display massive information can be seen directly through screen 4. use PWM digital power amplifier with above 90% efficiency and 300KHz carrier frequency to have advantages of low distortion little heating high efficiency 5. Perfect protection function: voltage short circuit alarm open circuit and over load alarm 6. Built-in OCXO for 50KHz high precision impulse output which can be used to calibrate energy meter clock also can test day error/hour segment error when matching with meter calibration software (optional) 7. With 485 communication interface can do various communications test for universal meters
1. Design with touch panel and mask button massive information to see and simple to use 2. built-in standard energy meter for digital closed loop feedback U I �¦ F W VAR VA PF all for reference 3. Perfect over circuit over voltage. short circuit open circuit over heat over load protection 4. Three phase rated current rated voltage can be preset by users 5. Multiple choose of voltage current phase testing point 6. Capable of measuring single phase three phase active power energy meters and reactive power energy meters 7. Large memory for data storage and searching data is very convenient 8. With R232 communication interface for PC control and software upgrade
VLF (Very Low Frequency) Testers are suitable for testing power cables transformers switchgear rotating machinery and other electrical apparatus. 1. Data of current voltage wave form can be directly sampled at high voltage side so the data is real and accurate. 2. Overvoltage protection: If the output exceeds the set limit of voltage the instrument will shut-down to protect itself the actuation time is less than 20ms. 3. Overcurrent protection: It is high-low voltage dual protection in the design the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current the instrument will take shut-down protection the actuation time are both less than 20ms. 4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protect
Product Introduction Dc Hipot Test Equipment for the power supply department, for example: DC HV withstand and leakage current test in power cables, the conductance current and 1mA reference voltage of magnetic blow out arrester and zinc oxide arrester test.ZGF DC Hipot Test Equipment supplies 60kV to 400kV from 60kV to 400kV is DC high voltage power supply equipment.It has functions of switch on protection under 0 voltage,over voltage and over current protection.They are high stability and reliability. ZGF is easy to operate , small in size and light in weight. product features Product Characteristics 1 Series dc high voltage generators have small ripple coefficient stable and reliable voltage output no noise and good reliability 2 with overvoltage overcurrent zero voltage start and fault protection voltage protection value can be set display intuitive 3 voltage current using digital display and power supply has a reading easy to monitor the output status 4 with 0.75 times voltage conversion easy to test zinc oxide arrester 5 the product structure is compact small size easy to carry
product brief introduction Product Introduction The Test Transformer(ac dc hipot tester) calls the booster it is the basic test equipment used by the power station supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products electrical equipments and insulated materials testing the insulated level of products discovering the insulated objection of quizzee scaling the capacity burdened voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance, and light weight. 3. Dry type high voltage testing transformer: light weight, light volume, can run backward, price expensive. 4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install. warning 1. Test transformer should be applied into use with control unit as for how to use control unit please see Operation Manual of Control unit. 2. Screening wire should be applied into the direct current test to avoid straying leakage. After test discharge rod is applied to release the restored electricity. 3. The end of high frequency voltage filtering capacitance should be connected with the ground wire together with crust of control unit to connect with the earth wire. 4. The whole test should follow the regulation in high frequency voltage test site should pay more attention to the safety of equipment and body.
Product description Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source. Electrical parameters Electrical parameters Accuracy class 0.05, 0.1 Power supply Single phase AC 85-265V, 50 60 Hz AC Voltage output Range 57.7V 100 V 220V 380V, Switch automatically max 500V Adjustment resolution 0.01, 0.1, 1 10,
Condition New Warranty one year Application Industrial Automation Technical consulting support Yes MOQ 1 Shipping options DHL FEDEX UPS EMS Supply ability 200 piece pieces per week RELATED PRODUCTS FC-IO-0001 FC-SDO-0824 FC-SAI-1620M FC-PDB-0824 FC-TPSU-2430 FC-TSAI-1620M FC-TSDI-1624 FC-TSDO-0824 FC-PSU-UNI2450U FC-DCOM-232 485 FTA RS232 485 CC RS232 485 10024 F F 10024 H F 10024H I 10024 I F 10024 I I 10005 1 1 10005 1 1 10006 2 1 10001 R 1 10018 2 U 10310 2 1 10311 2 1 10303 1 1 10300 1 1 10106 2 1 10201 2 1 10215 2 1 10216 2 1 10209 2 1 10105 2 1 10102 2 1 10205 2 1
Overview High pressure wireless phase detector is a dedicated test high-voltage nuclear phase tester based on national power industry standard norms and market demand, and high-voltage nuclear photographic applies to detecting the two-sided circuit breaker of the ring or dual power supply power network closed loop circuit breaker. Whether it is produced in the same phase. Before the closed loop two power supply, you must perform a nuclear phase, otherwise a short circuit can occur, suitable for the 6KV 220KV transmission line with the electrical core, the sight can reach 200 meters, and the wall can be used, and it has a test function. Wireless high pressure cores use wireless transmission technology, safe and reliable operation, easy to use, in line with national electric power safety equipment quality supervision and testing standards. Compared with the cable core, it is the main advantage that the lead wire connected to both grids power supply is removed, and the safety is used to improve the security in a manner that is not subject to any terrain and facility architecture. Technical parameter Phase difference Error 5 Frequency accuracy 0.1Hz The voltage grade measured by this product is 6kv 220kv Transmission distance of the transmitter and receiving host
Overview The digital millisecond tape RS232 communication interface is widely used in electric power, electronics, telecommunications, railway, transportation and electromechanical, mechanical and other departments. It is used to measure the electromagnetic contact, remote device, and automatic device various action time, action intervals, machinery. The contacts, contacts, power switch main contacts, time, three phases, interval, tensile interval, tensilate, slightly separation, interval between closures, hierarchics, tensile gain machine B contact, and Active pulse lines such as various band switches, lock switches, limit switches, and universal conversion switches are also available for sports, and measure the speed of the A point to the B point. Technical parameter Measuring range 0.0001 999.9999 seconds Timing accuracy 0. 01 2 words power supply AC 220V 10 50Hz power 5W input signal Mechanical air contact or electrical signal 5 20V Reset method Manual or software clearing Relative humidity 80 RH Dimensions 195 175 80 weight 1.5 kg Intelligent digital millisecond 1Intelligent digital millisecond
Product description Current Transformer Analyzer is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry. Technical Parameter CTA-1000 Usage CT PT Output 0~180Vrms12Arms36Apeak value Voltage measurement accuracy 0.1% CT Ratio Range 1~40000 accuracy 0.05% PT Ratio Range 1~40000 accuracy 0.05% Phase Range 2min accuracy 0.5min DC resistance Range 0~300 accuracy 0.2%2m Burden Range 0~1000VA accuracy 0.2%0.02VA 0.2%0.02VA Power supply AC220V 10%50Hz Environmental Conditions Operating temperature -10C~50C Humidity 90% Weight and Dimensions Dimensions 365 mm290 mm153mm,Weight
Overview The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use. Technical parameter Input voltage Three-phase four-wire 3 380 (220) V 50Hz The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1 Output current Communication 0 20A Triple semi-digital display, accuracy: level 1 Maximum output capacity 3 300VA Three-phase coarse Ambient temperature
Overview Cable check and cable, cable lookups are a bit a bit of arbitrary wiring no need to publicly line. It can greatly improve the construction progress, which is a new test tool in on site construction such as electricity, telecommunications, automation control. The cable calibration equipment is based on the characteristics of foreign new types of wire tools, combined with the actual situation of China, using digital identification technology, making the test work simple and accurate. Technical parameter Parameter Display the maximum row of LEDs 1000, the maximum distance of the quilt is 40km 1.5mmmmmmmmma size Transmitter Size 135 70 24MM Receiver Size 135 70 24mm Function The entire instrument consists of a transmitter and a receiver; There is no need to determine the public line to make it easy to use Wire recognition, distribution, application to a part of the wire or multi-heeled wire One item can be identified, if you need to distinguish more wires can measure or use multiple instruments Can determine whether there is a short circuit or disconnect between the wires The receiver is also a disconnect detector that can be used to measure whether the wire is turned on The structure is small and easy to operate.
Overview The hand held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on site debugging experience and user communication in and has been re designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing. Technical parameter Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A-10A, error: no more than 0.01 The AC current is in the range of 10A-100kA, error no more than 0.03 Current resolution current is 0.001A in the range of 0A-100KA The AC voltage is in the range of 0V- 100V, error: no more than 0.01V The AC voltage is within 100V 1000kV range, error: no more than 0.03 Current resolution: current is 0.001V in the range of 0V-1000kV Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0-359 , the error is not more than 0.001 , the resolution is 0.01 Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s UCA consistency test Test through UCA IEC61850, and obtain the test certificate
Product description Transformer calibrator is a new automatic instrument. We apply advanced electronic technology in the design. By directly decomposing the error signal, it is able to display the percentage, phase error and orthogonal error statistically. It s quick and energy saving. And it s especially good for live testing due to its cute dimension and light weight. Technical Parameters Working Condition: (1) Temperature: 5 (2) Relative humidity:
Product Introduction This Transformer control boxof console is suitable for adjustable voltage control of 0.5-10kVA test transformer. Technical Indicators Maximum capacity 20kVA Input voltage 220kV Output voltage 0-250V Maximum output current 0-90A Mains phase number single-phase Power frequency 50HZ Instructions precision 1.5 Class Using Methods and Attention Matters 1.Check the test transformer measuring winding rated output voltage, and make it match the operation box correctly. 2. Connect the line between test transformer and operation box according to the wiring diagram. 3. Switch on the power supply, then close the knife switch, and the power indicator light, finally set the work time of relay. 4. Make the pressure regulator display zero, press the start button, the clockwise rotation of the hand wheel, until it reaches the required value. 5. Start the timing switch, timing begins, the electric bell will alarm automatically when it reaches the setting time(artificially controlled time if there is on alarming function), then break off the timing switch. Q&A: What is the difference between a control box and a box-type transformer The control box has only control functions. It is a control unit. Its main function is to issue instructions to control the rapid breaking of the circuit breaker in the box substation; it is a component in the box substation. The box-type transformer generally refers to the box-type substation, which integrates the functions of power transformation, power distribution, control, and protection.
Overview Light digital relay protection tester characteristics; 4/6/8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850-9-1 / 2 frame format, Goose, IEEE-1588 packets; more support 24 sets of SV packets +64 groups of Goose packets simultaneously; 3/5 pairs of 2 ~ 10M fiber serial port, can send and receive IEC60044-7 / 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value " 12 road simulation small signal output, provides testing of protection devices input for small signals; Technical parameter: Fiber Ethernet port 4/6/8 pairs 100 Mbits / S, ST, Mode, 1310nm; IEC61850-9-1 / 2 / Le, Goose, IEEE-1588; Send dispersion:
Overview The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact. Technical parameter: AC current output Output accuracy Level 0.5 Phase current output (effective value) 0 40A Three merge current output (effective value) 0 120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 1000VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (foundation) 20 1000Hz Harmonic number 1 20 times DC current output Output accuracy Level 0.5 Current output 0 10A / each phase, 0 20A / two superimposed Maximum output load voltage 20V AC voltage output Output accuracy Level 0.5 Phase voltage output (effective value) 0120V Line voltage output (effective value) 0210V Maximum voltage output value 0240V Phase voltage / line voltage output power 80VA /100VA Frequency range (fundamental) 201000Hz Harmonics 1 20 times
Overview Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient. I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test. CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS. Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test. 220V single power input and avoids the risk of using 380V. Current transformer volt-ampere characteristic tester Main Technical Parameters: Booster output current & voltage 1A/2500V 2A/1500V 5A/600V 10A/220V 20A/30V Current generator output current 600A Output power 3000VA Voltage and current measurement accuracy CT ratio tests Range 1 -40000 Voltage method / current method Accuracy PT ratio tests Range 1 - 40000 Accuracy