Overview
The hand held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on site debugging experience and user communication in and has been re designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing.
Technical parameter
Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A-10A, error: no more than 0.01
The AC current is in the range of 10A-100kA, error no more than 0.03
Current resolution current is 0.001A in the range of 0A-100KA
The AC voltage is in the range of 0V- 100V, error: no more than 0.01V
The AC voltage is within 100V 1000kV range, error: no more than 0.03
Current resolution: current is 0.001V in the range of 0V-1000kV
Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0-359 , the error is not more than 0.001 , the resolution is 0.01
Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s
UCA consistency test Test through UCA IEC61850, and obtain the test certificate
The hand-held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on-site debugging experience and user and has been re-designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing. Technical parameter Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A-10A, error: no more than 0.01A; The AC current is in the range of 10A-100kA, error: no more than 0.03%. Current resolution: current is 0.001A in the range of 0A-100KA The AC voltage is in the range of 0V- 100V, error: no more than 0.01V; The AC voltage is within 100V-1000kV range, error: no more than 0.03%. Current resolution: current is 0.001V in the range of 0V-1000kV Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0-359 , the error is not more than 0.001 , the resolution is 0.01 Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s UCA consistency test Test through UCA IEC61850, and obtain the test certificate
Overview The hand held network packet analyzer is a hand-held smart substation optical digital network analyzer. It is a new product that relies on the rich on-site debugging experience and user communication in and has been re-designed. It is a substation and the daily maintenance, detection, commissioning, monitoring and analysis equipment of manufacturers. With a new test method, a complete feature gives you a new experience of intelligent substation efficient and convenient testing. Technical parameter Voltage current output accuracy Voltage current measurement accuracy The AC current is in the range of 0A10A, error no more than 0.01A; The AC current is in the range of 10A-100kA, error: no more than 0.03 Current resolution current is 0.001A in the range of 0A-100KA The AC voltage is in the range of 0V- 100V, error: no more than 0.01V The AC voltage is within 100V-1000kV range, error no more than 0.03 Current resolution: current is 0.001V in the range of 0V1000kV Phase output accuracy Phase measurement accuracy The voltage current phase is in the range of 0 359 , the error is not more than 0.001 , the resolution is 0.01 Packet output synchronization Tester Different optical network ports packet output disabled time no more than 1s UCA consistency test Test through UCA IEC61850, and obtain the test certificate GOOSE input and output function The tester is really ready for the Goose output function, supports the output of 60 GOOSE control blocks, and the output message is required to meet the needs of the configuration file. The output message data type can support single point, double point, floating point type The tester has a Goose reception function, and the analysis of multiple Goose block messages can be performed. The statistics include channel variations, and displacement channel information.
Product Introduction SMG7000 Handheld Power Quality Analyzer Input Characteristics 1. Voltage measuring range: 0~400V auto. 2. Current measurement range 3. Clamp transformers (three): 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) 4. Phase angle measurement range: 0~359.99 �°. 5. Frequency range: 45~55Hz. 6. Voltage number of channels: three channels (UA UB and UC). 7. Current number of channels: three channels (IA IB IC). 8.Maximum number of harmonic analysis: 63 times. 9. Intervals of 1 minute maximum storage period: 18 months
SMG7000 Handheld Power Quality Analyzer Input Characteristics 1. Voltage measuring range: 0~400V auto. 2. Current measurement range 3. Clamp transformers (three): 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) 4. Phase angle measurement range: 0~359.99 �°. 5. Frequency range: 45~55Hz. 6. Voltage number of channels: three channels (UA UB and UC). 7. Current number of channels: three channels (IA IB IC). 8.Maximum number of harmonic analysis: 63 times. 9. Intervals of 1 minute maximum storage period: 18 months
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality canâ??t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics Voltage measuring range: 0 200V 800V, automatic cutting gear. Current measurement range Clamp transformers (three types): 5A / 25A (standard) 100A / 500A (optional) 400A / 2000A (optional) Phase angle measuring range: 0 ~ 359.99 . Frequency measurement range: 45 ~ 55Hz. Voltage channels: three-channel (UAã??UBã??UC). Current channels: three-channel (IAã??IBã??IC). Maximum harmonic analysis times: 63 times. Maximum continuous storage period in 1 minute interval: 18 months. 2. Accuracy
R&S ZVB8 Vector Network Analyzer Condition: Used. Good Working Condition Option: 2 ports, 8.5G
Supplier: Cable & antenna analyzer, calibrators, fiber optic, meter, oscilloscopes, power meter, signal generator, spectrum analyzers, thermal imager, network analyzers
Supplier: Otdr, fusion splicer, spectrum splicer, vector network analyzer, signal generators, fiber laser, broadband light source
Services: Transportation