Overview High voltage insulation megohmmeter is composed of medium and large scale integrated circuits. This meter has large output power high short-circuit current value and large output voltage grades (there are four voltage grades). The working principle is as follows: the DC high voltage generated by the battery inside the machine as power supply and converted by DC/DC reaches the L pole from the E pole by the tested product so as to generate a current from E to L pole. After I/V conversion and operation by the divider the measured insulation resistance value is directly displayed by LCD. Technical Parameters Working Conditions environment temperature relative humidity 85%RH output voltage level 500V 1000V 2000V2500V measurement range 019990M Resolution 0.01M0.1M1.0M10.0M relative error Voltage/load 2500V/20M Voltage drop about10% short-circuit current 1.6mA direct current 81.5V(AAR6)battery alternating current 220V/50Hz Power quiescent dissipation
Instrument and meters, temperature calibration equipment.
Overview The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use. Technical parameter Input voltage Three-phase four-wire 3 380 (220) V 50Hz The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1 Output current Communication 0 ~ 20A Triple semi-digital display, accuracy: level 1 Maximum output capacity 3 300VA Three-phase coarse Ambient temperature: 0 360 Move 30 per step
Product description Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source. Electrical parameters Electrical parameters Accuracy class 0.05, 0.1 Power supply Single phase AC 85-265V, 50 60 Hz AC Voltage output Range 57.7V 100 V 220V 380V, Switch automatically max 500V Adjustment resolution 0.01, 0.1, 1, 10 AC Voltage output Range 57.7V 100 V 220V 380V, Switch automatically max Adjustment resolution 0.01, 0.1 1, 10, Accuracy 0.05 RG Stability Better than 0.01 RG 1min Distortion degree Better than 0.1 not capacitive load Load capacity 40VA Full load regulation rate Less than 0.01 RG Full load regulation time Less than 1ms Temperature drift 8 PPM C Long-term stability 60 PPM year
Product description 120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard "Generation Requirement of Portable HVDC Generator"(ZGF 24003-90) Technique Index 1. power: AC220V+10%, 50Hz+1% 2. Output voltage indicator accuracy:
Tension controller, tension loadcell, tension amplifier, web guiding system, powder brake, powder clutch, power supply, tension meter.
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index Input characteristics Voltage measuring range 0 200V 800V, automatic cutting gear. Current measurement range Clamp transformers three types 5A 25A standard 100A 500A optional 400A 2000A optional Phase angle measuring range 0 359.99 Frequency measurement range: 45 55Hz. Voltage channels three channel UA UB UC Current channels three channel IA IB IC Maximum harmonic analysis times 63 times. Maximum continuous storage period in 1 minute interval: 18 months. Accuracy Measurement of electrical parameters section: Voltage 0.2% Frequency 0.01Hz Current, power 0.5% Phase 0.2 Power quality section Fundamental voltage tolerance 0.5% F.S. Fundamental current tolerance 1% F.S. Phase between fundamental voltage and current measurement erro0.2
Product description Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer. A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves). The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment. Technical Parameters Input voltage AC220V 50 Hz Output voltage 0~30kV Capacity 3kVA Test number 3 pairs each time Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg
Overview zinc oxide arrester tester is a special instrument used to test the electrical performance of zinc oxide arrester. The instrument is suitable for live or power failure detection of zinc oxide arrester of various voltage levels so as to timely detect the internal insulation damp and valve aging and other dangerous defects. zinc oxide arrester tester is easy to operate and easy to use. The whole measuring process is controlled by single chip microcomputer. It can measure the total current resistive current and its harmonics power frequency reference voltage and its harmonics active power and phase difference. The instrument uses digital waveform analysis technology harmonic analysis and digital filtering software anti-interference methods to make the measurement results accurate and stable. Parameter: 1. Full current measurement range: 0-10mA effective value 50Hz/60Hz accuracy: (reading 5% + 5a) 2. Measurement accuracy of resistive current fundamental wave (secondary method without Interphase Interference): (reading 5% + 5a) 3. Current harmonic accuracy: (reading 10% + 10a) 4. Reference voltage input range: 25V-250V RMS total harmonic content 30% 50Hz/60Hz 5. Reference voltage measurement accuracy: (reading 5% + 0.5V) 6. Voltage harmonic measurement accuracy: (reading 10%) 7. Angle between fundamental current and fundamental voltage: 0-360 8. Working time of battery: 6 hours of main engine charging power supply: 220 V 10% 50Hz/60Hz charging time: 5 hours 9. Host volume: 325 280 140 10. Host weight: 3.5kg (without cable)
Electrical testing and measuring instrument, high voltage withstand instrument, battery test, resistance test, power transformer, relay protection test, high voltage switch test, power cable test, ZNO arrester test, SF6 gas test, oil test, electrical evergy test, electrical safety tool.
Fiber optic cleaning pen, fiber optic cleaner cleans sc/st/fc ferrules, adapters, flange, patch cord connectors, fiber optic cleaning kit, fiber optic cleaning cassettes, cleaning stick/swab, cleaning ipa wipters, fiber optic power meter, otdr (time domain reflectometer), fiber splitter, fiber fusion splier, fiber electrodes.
Product description Single-phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source. Electrical parameters Electrical parameters Accuracy class 0.05%, 0.1% Power supply Single phase AC 85-265V, 50/60 Hz AC Voltage output Range 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) Adjustment resolution 0.01%, 0.1%, 1%, 10%, AC Voltage output Range 57.7V / 100 V / 220V / 380V, Switch automatically (max Adjustment resolution 0.01%, 0.1%, 1%, 10%, Accuracy 0.05% RG Stability Better than 0.01% RG/1min Distortion degree Better than 0.1% (not capacitive load) Load capacity 40VA Full load regulation rate Less than 0.01% RG Full load regulation time Less than 1ms Temperature drift 8 PPM C Long-term stability 60 PPM/year AC Current output Range Adjustment resolution Accuracy Stability Distortion degree Load capacity Full load regulation rate Full load regulation time Temperature drift Long-term stability 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically 0.01%, 0.1%, 1%, 10%, 0.05% RG Better than 0.01% RG/1min Better than 0.1% (not capacitive load) 40VA Less than 0.01% RG Less than 1mS 8 PPM C 60 PPM/year
Our high voltage testers cover full range: high voltage hipot tester, circuit breaker switchgear tester, transformer tester, relay protection tester, ct/pt tester, moa/insulator tester, sf6/insulation oil test equipment, resistance tester, etc..
Laser Diode Or Photodiode Aging Socket, Chip Loading Fixture And Laser Aging Plate, Etc.