Parameter DR-600 Fixed gas detector Detection Gas Methane (CH4) Range 0-100%LEL Min Reading 1%LEL Display Error �±5%(F.S) Transmission Distance 1,200m Alarm Point Low Alarm:20%LEL High Alarm:50%LEL Rated Power 2.5W Output Signal 4-20ma/RS485 Detection Way Diffused Response Time â?¤60s Cable Specification Three wire system RVVP3*1.0mm2 Working Temp -10â??~55â?? Working Humidity 10~93%RH Storage Temp 10â??~35â?? Sensor Type Catalytic Combustion Power Supply DC24V Production Grade Exd IIC T6 Gb Protection Grade IP66 Electrical interface M20*1.5mm2 Alarm Way Sound alarm Sensor Life Clean air for 2 years Way to Install Fixed bracket/tube mounting/wall mounting Weight 1.75kg Size 210*190*95mm
Product Name: YUTONG Bus Spare Parts-Starter-3708-00029 Product Description: Mainly used for YUTONG Buses, Parts Number: 3708-00029 Packaging Method: Wooden cases or Carton boxes or designed by customers' requirements. Delivery Method: By sea or by air or discussed with customers. Delivery Time: Within 10 workdays after receiving the deposit. Trade Term: EXW, FOB, CFR, CIF, DAF, etc. After-sales service: Response and provide satisfactory solutions within 24 hours. Our Advantages: Competitive Price ; Durable Quality ; On Time Delivery ; Excellent After-sales Service.
leak tester (0- -90KPA) for testing of the leakage of the packaging . meet the astm D3078 standard. we have 3 different chambers 210*270mm 360*585mm 460*330mm.
ZHUOJUN redispersible polymer powders are manufactured by spray drying macromolecular copolymer dispersions under carefully defined conditions. They are mainly used improve cohesion, adhesion and flexibility in constructions especially in drymix mortar. Composition: Polymer Resin It is the main ingredient of dispersion particle and a key part for redispersible polymer powders to come into play. Additives (interior) It plays a role of modified resin with polymer resin. Protective Colloid A layer of hydrophilic material will be coated on the surface of the redispersible polymer powder. The protective colloid of most redispersible polymer powder is polyvinyl alcohol. Additives (exterior) The anti-caking agents and super-fined mineral additives are incorporated to make sure that powder properties are maintained during storage and processing.
Application GC-7960 Ethylene Oxide Residue Tester applies to test of solvent residue on various printing films, laminated films, extrusion films, various drug-use films and sheets as well as various kinds of sterilization apparatus and instruments. Standards YBB20162012ã?�YBB20172012ã?�YBB20182012ã?�YBB20252012ã?�YBB20262012ã?�YBB20272012 -
Application GC-7960 Organic Solvent Residue Tester applies to test of solvent residue on various printing films, laminated films, extrusion films, various drug-use films and sheets,. Technical Indexes 1.Temperature Control: Oven: room temperature +8~420°C, accuracy ±0.1°C (at 200°C) Injector: room temperature +8~420°C, accuracy ±0.1°C (at 200°C) -
Application Applies to best parameters determination of heat sealability of various kinds of film. Heat sealability of film depends on temperature, pressure and heat time and the HSL-6001 Heat Seal Tester is widely used in food and pharmaceutical packaging industries. Features 1: Our own patent technology 2: Embedded system control 3: Touch screen operation, easy to operate 4: TFT LCD display, UI flattening design 5: Dual heat jaws, temperature controlled independently 6: Micro-printer prints mini-report 7: Pressure easy to adjust, heat temperature and time touch screen input. 8: Emergency stop button, safety design to prevent burns 9: Over temperature protection, over pressure protection 10: Silence working 11: DB9 RS232 communication port. 12: DSM system is optional(Laboratory Management Information System), easy to manage and share test data. Technical Indexes Heat temperature: Room temperature+6 ~ 300â?? Accuracy: ±0.2 â?? Dell time: 0.1~ 999.9s Pressure: 0.05 MPa~1.1MPa Heat jaw surface: 265mm Ã? 12 mm (customized) Heat jaws: 2, controlled independently Gas source pressure: 0.05MPa ~ 1.1MPa (self-provide) Gas source interface: Ф6mm Outer dimension: 536 mm (L)Ã?335 mm (W)Ã?413 mm (H) Work noise: 0db Power supply: AC 220V 50Hz Net weight: 33kg Standards QB/T 2358(ZBY 28004)ã?�ASTM F2029ã?�YBB 00122003 Configuration Delivery: main unit, micro-printer, footswitch, sample feeding rod. Optional: Communication cable, DSM system -
Application Applies to best parameters determination of heat sealability of various kinds of film. Heat sealability of film depends on temperature, pressure and heat time and the HSL-6001 Heat Seal Tester is widely used in food and pharmaceutical packaging industries. Features 1: Our own patent technology 2: Embedded system control 3: Touch screen operation, easy to operate 4: TFT LCD display, UI flattening design 5: Dual heat jaws, temperature controlled independently 6: Micro-printer prints mini-report 7: Pressure easy to adjust, heat temperature and time touch screen input. 8: Emergency stop button, safety design to prevent burns 9: Over temperature protection, over pressure protection 10: Silence working 11: DB9 RS232 communication port. 12: DSM system is optional(Laboratory Management Information System), easy to manage and share test data. Technical Indexes Heat temperature: Room temperature+6 ~ 300â?? Accuracy: ±0.2 â?? Dell time: 0.1~ 999.9s Pressure: 0.05 MPa~1.1MPa Heat jaw surface: 265mm ? 12 mm (customized) Heat jaws: 2, controlled independently Gas source pressure: 0.05MPa ~ 1.1MPa (self-provide) Gas source interface: Ф6mm Outer dimension: 536 mm (L)?335 mm (W)?413 mm (H) Work noise: 0db Power supply: AC 220V 50Hz Net weight: 33kg Standards QB/T 2358(ZBY 28004)?�ASTM F2029?�YBB 00122003 Configuration Delivery: main unit, micro-printer, footswitch, sample feeding rod. Optional: Communication cable, DSM system -
Application For the determination of gross leaks in �exible packaging containing a headspace gas by bubble emission method. Standards ASTM D3078, GB/T 15171 More Deatil: Grace -
Application OTR-1901 is based on the coulometric sensor method and available for the OTR test of flexible films, sheeting and packages. It can test 3 specimens in one operation with independent results. Technical indexes Test range� Film: 0.01-6500 cm3/m2·d (Standard) 0.07-6,5000 cm3/m2·d (Optional) -
GTR-7004 tester is suitable for the analysis and determination of the porosity, the air permeance and the air resistance of various kinds of battery separation membranes, paper, paperboard, textiles, non-woven fabrics and other materials.
Application GTR-7004 tester is suitable for the analysis and determination of the porosity, the air permeance and the air resistance of various kinds of battery separation membranes, paper, paperboard, textiles, non-woven fabrics and other materials. Features Standard Gurley, Low Pressure Gurley, High Pressure Gurley Sheffield units, Bendtsen units Interchangeable test heads Output in seconds, other unit optional Embedded system, remote service Touch screen operation Test data and curve real time display Built in data query function Built in micro-printer to print reports Automatic overload protection. Highly accurate sensors to ensure the accuracy and repeatability. Swagelok piping system, to ensure system tightness and long-term stability Advanced control device, reliable operation and long service life Standard communication interface, configurable professional computer software The calibration can be traceable to ensure the measurability of the test data Support DSM system Technical indexes Test Range: 30,60,000 Gurley seconds,Standard, 0.0021,200um/Pa.s,Standard, 300,60,000Gurley seconds,Optional, 0,60,000 Gurley seconds,Optional, Resolution, 0.1 Gurley seconds Sample Amount, 1 ,Standard,,3 can be customized. Differential Pressure,0.01kPa,20kPa,STD,1.22kPa, Accuracy: 0.01kPa Test Area: 1.0in2. ,0.25in2, 0.1in2 optional, Sample Thickness: ,5mm Test Gas: Air, O2, N2, CO2,Self-provide, Gas Resource: 0.3MPa,1.0MPa Interface: Ф6mm Dimension: 320mm,L,�380mm,D,�410mm,H, Power Supply: AC 220V 50Hz Net Wt. 25 kg Standard ISO 5636.5,ASTM D726, TAPPI T460,TAPPI T536,TAPPI T538,TAPPI T490 Configuration Delivery,Mainframe, Test Head (1.0in2), Super Filter, Precision Pressure Regulator. Optional: Sample Auto Feeder, Calibration Equipment,Test Head(1.0in2), Test Head(0.25in2),Test Head(0.1 in2). Note: Specifications are subject to change without prior notice.
Application GTR-7001 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes. Features Vacuum differential pressure method Patent technology 3 specimens test simultaneously and independently Computer control One-button test, test automatically through whole process High accuracy vacuum sensors embedded in 3 Chambers with independent temperature sensor Test under various RH conditions with Humidity generator (optional) Environment temperature and humidity sensor inside Permeability coefficient ,solubility coefficient and diffusion coefficient test Chambers with water bath temperature control technology Unit based on embedded system,24bit AD Multiple test modes optional Data curves display Traceable reference film calibration Supports DSM system (DSM, lab data management system) Technical Indexes Test range: 0.01 - 190,000 cm3/m2�24h�0.1MPa (Standard) Resolution: 0.001cm3/m2�24h�0.1MPa Samples: 3, independent Vacuum accuracy: 0.1Pa Temperature range: 5C - 95C Temperature accuracy: ±0.1C Humidity range: 0%RH,35%RH-90%RH,100%RH (optional) Humidity accuracy: ±1%RH (optional) Sample thickness: less 5mm Sample size: >= 150mm * 94mm Test area: 48cm2 Test gas: O2, N2, CO2, He, etc Differential pressure: -0.1MPa - 0.1MPa Gas interface: Ф8mm Dimension: 730mm * 510mm * 350mm Power supply: AC 220V 50Hz Net wt. : 63kg Standards ASTM D1434, ISO 15105-1,ISO 2556,GB/T 1038-2000,JIS 7126-1,YBB 00082003 Configuration Delivery: Main unit, computer, G-TRANS software, Temperature controller, vacuum pump(BOC Edwards), tank regulator, PCIE card, communication cable, sample cutter, vacuum grease. Optional: Humidity generator, Reference film, vacuum grease, sample cutter, DSM system.
Application Wvtr-9001 is based on the electrolytic sensor method and available for the water vapor permeability test of flexible films, sheeting and packages. It can test 3 specimens in one operation with independent results. Features Electrolytic sensor method Patent technology Film and package test 3 specimens test simultaneously and independently One-button test, test automatically in whole process Multiple test modes optional Data curves display Computer control Digital flow adjustment 3 chambers with 3 temperature sensors Environment temperature and humidity sensor inside Chambers water bath technology Unit based on embedded system, 24bit î?-î£ ad Pressure, ppm water sensor and temperature overload protection Traceable reference film calibration Supports dsm system (dsm, lab data management system) Standard Iso 15106-3, gb/t 21529, din 53122-2, ybb 00092003 Configuration Delivery: main unit, computer, w-trans software, temperature controller, tank regulator, pcie card, communication cable, sample cutter, vacuum grease. Optional: package fixtures, reference film, vacuum grease, sample cutter, dsm system.
Front loading washing machine 6.0kg--10kg front loading washer for exporting now. 1pc/carton
Whip check Safety cable 1.Keywords: Whip check safety cable, whip checks, king safety cable, Hose safety whip check, air hose safety cable, whip check cable. 2.Whip check safety cable, whip checks, king safety cable, Hose safety whip check, air hose safety cable, whip check cable Material: steel plated cable, plated spring and Aluminum ferrules, Stainless steel cable and copper ferrule is available. Size: 1/8*20 (for 1/2 hoses to 1-1/4 hoses) Length: 20-1/4inch 1/4*38(for 1-1/2 hoses to 3 hoses) Length: 38inch 3/8*44(for 4 hoses) Length: 44inch Max Pressure: 200PSI 3.Usage: Whip check safety cable is designed specially to prevent hose connections from whipping if the hoses or couplings failed to hold. The failure usually occurs with high pressure and will make hoses or equipment shake violently which may cause serious injury for people or the nearby coupling & equipment. 4.We aslo sell hose couplings ( Camlock, Sotrz, Bauer Guillenmin couplings ), stainless pipe fittings, valves, flanges, sanitary fittings and valves and so on. 5.If any of them be of interestedto you, please no hesitate to contact. 6.Packing : polybag inside, cartons outside; Delivery time:30days on we signed order. 7. Terms of payment: T/T, L/C,30% deposit. Delivery Port: FOB Qingdao.
HG-CPJ-32 washing machines we invent are the latest design of a new type of blunt outside inside shower of machinery which combine internal and external machine structure theory and designed on the basic of the require of the user. Their outstanding features are: 1. Apply to new and old bottles in various types and materials. 2. Spray outside, wash twice inside, and wash the bottle wholesomely and clean. 3. Wide adaptability and low water consumption using water pressure. 4. Simple structure and convenient maintenance. Its appearance is beautiful and corrosion resisting with using the stainless steel water bucket 5. Save labor and effort; high efficiency. Apply to small and medium-sized beverage manufactory
?equipment model and name Csl-y impact specimen gap hydraulic broaching machine ? equipment usage Impact specimen notch broaching machine is the dedicated and affiliated equipment with metallic pendulum impact testing machine, the machine adopts hydraulic drive, electric control the rise and fall of broach, broach lifting speed can be adjusted, adopting the lubricating oil to lubricate blade mouth parts at the same time, to ensure the sample accords with a requirement gap size and surface finish.The machine due to the use of a forming principle, the machining gap of good identity. Broach manufactured high-quality high-speed w18cr4v steel alloy, and its high hardness, good wear resistance, long service life, per knife can be processed more than 20000 samples. ? applicable standard Gb/t229-2007« metal material charpy pendulum impact test method»; Astm e23-02a«metal material gap specimen standard impact test method»; Iso148-2008«metallic materials-charpy pendulum impact test»; Din 50 115-1991«metal material impact test special sample size and fracture judge» Iv main technical parameters Sample notch type U type(u2, u3, u5), v type(v2) Processing sample size 10×10(7.5 or 5)×55mm Broach hardness =hrc65 Installed broach quantity 2 Cutting speed 2.5m/min ( can adjust) System pressure 2.5mpa Hysraulic oil storage 25l Broach stroke 340mm(u2, v2), 390mm(u5) Broach materials W18cv4v Motor power 370w Dimensions 480mm×660mm×1200mm (l×w×h) Weight 200kg V standard configuration 1.Host one 2.V2 broach one 3.U2 broach one Vi optional accessories 1. U3 broach 2. U5 broach
Model: KR90A Lens Material: High Borosilicate Optical Glass Gasket Material: 304 Stainless Steel Ring Material: High Quality Silica Gel Working Temperature: -40 Power: 50W-300W Light Transmittance: 93% Application: Street Lights, Mining Lamps, Tunnel Lamps, Spot Lights, etc
Model Scsj-i 02mm Weight 12-20kg 394¡¨¢390¡¨¢502mm