Application
GTR-7001 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Features
Vacuum differential pressure method
Patent technology
3 specimens test simultaneously and independently
Computer control
One-button test, test automatically through whole process
High accuracy vacuum sensors embedded in
3 Chambers with independent temperature sensor
Test under various RH conditions with Humidity generator (optional)
Environment temperature and humidity sensor inside
Permeability coefficient ,solubility coefficient and diffusion coefficient test
Chambers with water bath temperature control technology
Unit based on embedded system,24bit AD
Multiple test modes optional
Data curves display
Traceable reference film calibration
Supports DSM system (DSM, lab data management system)
Technical Indexes
Test range: 0.01 - 190,000 cm3/m2â?¢24hâ?¢0.1MPa (Standard)
Resolution: 0.001cm3/m2â?¢24hâ?¢0.1MPa
Samples: 3, independent
Vacuum accuracy: 0.1Pa
Temperature range: 5C - 95C
Temperature accuracy: ±0.1C
Humidity range: 0%RH,35%RH-90%RH,100%RH (optional)
Humidity accuracy: ±1%RH (optional)
Sample thickness: less 5mm
Sample size: >= 150mm * 94mm
Test area: 48cm2
Test gas: O2, N2, CO2, He, etc
Differential pressure: -0.1MPa - 0.1MPa
Gas interface: Ф8mm
Dimension: 730mm * 510mm * 350mm
Power supply: AC 220V 50Hz
Net wt. : 63kg
Standards
ASTM D1434, ISO 15105-1,ISO 2556,GB/T 1038-2000,JIS 7126-1,YBB 00082003
Configuration
Delivery: Main unit, computer, G-TRANS software, Temperature controller, vacuum pump(BOC Edwards), tank regulator, PCIE card, communication cable, sample cutter, vacuum grease.
Optional: Humidity generator, Reference film, vacuum grease, sample cutter, DSM system.
Application OTR-1901 is based on the coulometric sensor method and available for the OTR test of flexible films, sheeting and packages. It can test 3 specimens in one operation with independent results. Technical indexes Test range� Film: 0.01-6500 cm3/m2·d (Standard) 0.07-6,5000 cm3/m2·d (Optional) -
GTR-7004 tester is suitable for the analysis and determination of the porosity, the air permeance and the air resistance of various kinds of battery separation membranes, paper, paperboard, textiles, non-woven fabrics and other materials.
Application Wvtr-9001 is based on the electrolytic sensor method and available for the water vapor permeability test of flexible films, sheeting and packages. It can test 3 specimens in one operation with independent results. Features Electrolytic sensor method Patent technology Film and package test 3 specimens test simultaneously and independently One-button test, test automatically in whole process Multiple test modes optional Data curves display Computer control Digital flow adjustment 3 chambers with 3 temperature sensors Environment temperature and humidity sensor inside Chambers water bath technology Unit based on embedded system, 24bit î?-î£ ad Pressure, ppm water sensor and temperature overload protection Traceable reference film calibration Supports dsm system (dsm, lab data management system) Standard Iso 15106-3, gb/t 21529, din 53122-2, ybb 00092003 Configuration Delivery: main unit, computer, w-trans software, temperature controller, tank regulator, pcie card, communication cable, sample cutter, vacuum grease. Optional: package fixtures, reference film, vacuum grease, sample cutter, dsm system.
Air permeability tester is suitable for the analysis and determination of the porosity, the air permeance and the air resistance of various kinds of battery separation membranes, paper, paperboard, textiles, non-woven fabrics and other materials.
Application GTR-7004 tester is suitable for the analysis and determination of the porosity, the air permeance and the air resistance of various kinds of battery separation membranes, paper, paperboard, textiles, non-woven fabrics and other materials. Features Standard Gurley, Low Pressure Gurley, High Pressure Gurley Sheffield units, Bendtsen units Interchangeable test heads Output in seconds, other unit optional Embedded system, remote service Touch screen operation Test data and curve real time display Built in data query function Built in micro-printer to print reports Automatic overload protection. Highly accurate sensors to ensure the accuracy and repeatability. Swagelok piping system, to ensure system tightness and long-term stability Advanced control device, reliable operation and long service life Standard communication interface, configurable professional computer software The calibration can be traceable to ensure the measurability of the test data Support DSM system Technical indexes Test Range: 30,60,000 Gurley seconds,Standard, 0.0021,200um/Pa.s,Standard, 300,60,000Gurley seconds,Optional, 0,60,000 Gurley seconds,Optional, Resolution, 0.1 Gurley seconds Sample Amount, 1 ,Standard,,3 can be customized. Differential Pressure,0.01kPa,20kPa,STD,1.22kPa, Accuracy: 0.01kPa Test Area: 1.0in2. ,0.25in2, 0.1in2 optional, Sample Thickness: ,5mm Test Gas: Air, O2, N2, CO2,Self-provide, Gas Resource: 0.3MPa,1.0MPa Interface: Ф6mm Dimension: 320mm,L,�380mm,D,�410mm,H, Power Supply: AC 220V 50Hz Net Wt. 25 kg Standard ISO 5636.5,ASTM D726, TAPPI T460,TAPPI T536,TAPPI T538,TAPPI T490 Configuration Delivery,Mainframe, Test Head (1.0in2), Super Filter, Precision Pressure Regulator. Optional: Sample Auto Feeder, Calibration Equipment,Test Head(1.0in2), Test Head(0.25in2),Test Head(0.1 in2). Note: Specifications are subject to change without prior notice.
Application :- This is a premium product of electrical wires from \'JPCL\'. These cables are ideal for wiring in residential and commercial complexes, high-rise buildings, hotels, hospitals, schools, colleges, etc. (where the density of people is high). During a fire, these cables not only emit less smoke and toxic hydrochloric acid gas but also retard the spread of fire enabling those trapped inside to escape safely. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance resulting in power saving. These wires are insulated with a special grade PVC compound formulated and manufactured in-house only. The insulation is far superior in terms of critical oxygen and temperature index as well as in light transmission and acid gas generation. The skin coloration offers high insulation resistance and long life. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.75, 1.00, 1.50, 2.50, 4.00 and 6.00 Sq. mm Color Codes : Red, Yellow, Blue, Black and Green (For Earthing) Specification : IS:694 Packing : In 90 meter coils in attractive cartons
Supplier: Fluke, flir, thermal imager, multimeter, hvac, spectrum analyzer, megohmmeter, ground tester, oscilloscope, xrf analyzer
Services: Distributor and wholesaler
Features 1: 2 patents and 2 counts of software copyright registration. 2: iso, astm, gb and customized test mode. 3: highly accurate load cell, ac-servo drive. 4: test speed can be set freely in the range. 5: touch screen operation. 6: real color tft lcd display. 7: wide range sample thickness test available. 8: sled mass freely input. 9: micro-printer built-in. 10: overload, limit position protection. 11: low power consumption and silence running.
Features 1. Our own patent technology. 2. Large size touch screen operation. 3. Designed based on various standards. 4. Falling ball test available. 5. Method a, method b, customized method available. 6. Test results, curve display. 7. Result multiple units display. 8. Micro-printer prints mini-report. 9. High performance pneumatic sample clamp. 10. Foot pedal operation available. 11. Safety cover. 12. Result statistics. 13. Rs232 communication port. (optional)