Mobile High frequency C-arm X-ray Machine YSX0701 C-arm X-ray Machine Introduction: The clinical applications of this C-arm X-ray machine include orthopedics (arthroplasty, joint nailing, joint fluoroscopy, restoration and fixation for bone injury in emergency), radiology (abdominal organ angiography, gastrointestinal fluoroscopy), gynecology (uterus angiography), urology (kidney and bladder angiography), surgery (pacemaker implantation, peripheral vascular examination, etc.) and so on. Key Features of C-arm X-ray Machine: 1. Adopts the true digital high frequency host, gets the clearest and richest image with minimum dose, greatly reduces the potential harm of x-ray to clinicians and patients. 2. The unique double displays make operation intuitive, easy and reliable. 3. The vertical and horizontal movements and rotation of C-arm are all electric maneuvered. 4. Micro-computer based controller features with failure self-diagnostic function, easy maintenance. 5. Digital interfaces optionally equip with picture collection & storage workstation, directly upgrade the digital image system, to provide a short cut for your heavy file management. Upgraded Digital Image System of C-arm X-ray Machine: 1. Up to 100,000 static images stored in hard disk 2. Multi-image simultaneously display 3. Image processing functions: rotation, overturn lightness and contrast adjustment 4. Diagnostic report by laser printer Technical Data: Generator power/Frequency 3.5kw/40KHz 5kw/40KHz Radiography KV 40-110KV 40-120KV Radiography mA 30-70mA 24-70mA Fluoroscopy KV 40-110KV 40-120KV Fluoroscopy mA 0.1-5mA 0.1-5mA Pulse fluoroscopy 0.1-8mA 0.1-8mA Focus size 0.6í-1.5mm 0.3í-0.6mm Stationary anode Rotation anode Anode heat capacity 30KJ(40kHU) 150KJ(200kHU) Heat capacity of 500KJ(667kHU) 600KJ(800kHU) Collimator Iris, auto-tracking, variable visual field, double leaf Focus-to-image intensifier distance(SID) 1000mm 1000mm C-arm depth 730mm 730mm C-arm open 815mm 815mm C-arm arc glide with full balance 115íp 115íp C-arm rotation(motored) í+180íp í+180íp Upward and downward movement(motored) 400mm 400mm Forward and backward movement(motored) 200mm 200mm Horizontal swing angle í+12.5íp í+12.5íp Image intensifier 9" metal screen intensifier Camera High speed CCD camera Monitor 14" high resolution monitor Panel Two operation panels, automatic display error codes Image memory Store 8 images, freeze the last image, multilevel denoise, double displays in one screen Supply power 220V,50Hz,20A Power capacitor 4KVA . GW:300KG NW:240KG.
600mA TV Remote Control Medical Diagnostic X-Ray Radiography Machine YSX0603 1. Microcomputer control x-ray radiography assembles: optional 600mA. 2. Total 432 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain. 3. X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S. 4. Bulb type over remote-controlled diagnostic table and image intensifier television system are installed. They realize not only bright operation, but also supply convenience for science resonator suffer are reduced. Specifications of automatic spot-film are abundant. There are also automatic collimators for users convenience. 5. Applied in all kinds of hospital for radiography such as general body, beam filtration, and chest. Department Technology parameters High voltage generator control table and high voltage transform assemble Fluoroscopy Tube currency 0.3-5mA continuous currency Tube voltage 50-110KV continuous voltage Radiography Tube currency 32-630mA shift Tube voltage 45-125KV continuous voltage Exposure time 0.01-6.3s 23 shift Power Voltage 380Ví+10% Frequency 50Hzí+1Hz Capacity í¦50KVA Inner resistance í_0.3ª+ X-ray assembly Focus 1í-1.2í-2 double focal Rated rotate speed of anode 2800r/min Changed beam limited device Diagnosis table YS09D Automatic, adjusted field of view CS15Electro-motion diagnostic table The table body rotation "-15ípí½0ípí½+90íp" Focus to film distance 1100í½1500mm,adjustable manual 360ípfoot board The table to height 870mm Stationary grid Grid density 40L/cm Grid ration 10:01 Focusing distance 120cm Spot film device Scope of moving Longitudinal moving: 900mm; Transverse moving: í+120mm Specification of scope film Full :8"í-10", 10"í-12", 11"í-14", 14"í-14" Two: 8"í-10", 10"í-12" Three:11"í-14", 14"í-14" Four: 11"í-14", 14"í-14" Medical television system configuration 9ísx-ray image intensifier made by Toshiba, CCD camera,14ís high resolution monitor 14ísmonitor resolution Horizontal centerí¦1000 TV line Gray scale í¦10 grades Video width >12MHZ Mode of scan 625 lines, 5 field, Interlaced scanning Geometry distortion
High Frequency Mammography unit(tube import from other country) YSX0902 X-ray Generator Generator Type:High Frequency Inverter 30-60kHz Input Power: Single phase 220VAC, 50/60Hz Radiographic Ratings:Large Focal Point 22-39KV/1-600mAs Small Focal Point 22-39KV/1-100mAs Power Rating:5.5kW X-ray Tube Model:IAE X-ray Tube Anode rotation rate: 0000 rpm Focal Spot Size: Dual Focus 0.1 / 0.3mm Target Material:Molybdenum (Mo) Port Material:Beryllium (Be) Anode Heat Storage: 300KHU Anode Cooling:Air cooling Filtration: Mo(0.03mm),Al(0.5mm) Radiographic Stand C-ARM:Vertical Movement:60cm (70~130cm) Motorized Rotations Deg:í+180íp Motorized (Deg.Data Display) SID: 65cm Cassette Image Receptor Bucky Device:18í-24cm Bucky drive mechanism Grid Ratio:5:1 ,30 Line/cm Line Voltage 220V,Single phase Weight 240kg Comfortable Compression When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range. Tissue Compression: Manual and Motorized (Max 20kg) Compression Force and Thickness Data Display Micro Control's Compression Automatic Release Intelligent Automatic Exposure Control(AEC) With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography. Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV Type:Solid-State Detector or PMT Detector Microprocessor Control AEC Mode:Full AEC(Auto kV) Semi AEC (KV Select) Manual (kV,mAs Select) Density Adjustment:16 density steps. GW:300kg NW:240KG.
100mA mobile x-ray machine YSX0410 GENERAL 1. Used in ward and emergency treatment room for radiography. 2. Combined x-ray generator. 3. Single focus, bridge rectification. 4. It is precise safe, reliable and flexible. 5. Remote control device(control rangeí¦5m)is used. Unit Configuration Control table, HT generator unit, Ht cable, X-ray tube unit . Main Characteristics 1. Single table and single tube. 2. Design according to the electric mechanism of middle-size machine ,The function is reasonable. 3. The high-tension system is of march-past structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation. 4. Supply voltage (V), roentgenoscopy, radiography (kv) and stepless adjust able. 5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output. 6. Equipped with the capacity limitation and portection circuit and KV mA S interlock limitation and protection. 7. Adopt the digial circuit timer, grade according to R10 priority coefficient and can control time exactly. 8. Diagnostic table is of electric back rotation and is equipped with vibrating filter-ray device. 9. The spot film device of luminescent serene can hold the film jecket of various sizes and can make the photography of full-film and two sectional films separateiy. 10. The column has the bottom track only, which is easy while installation. MIN TECHNICAL INDEXES X-ray generator : Stationary anode, single focus and bridge silicon rectification. The x-ray generator is an oil-immersed self-cooled unit. Max rated capacity Current 15mA 30mA 60mA 100mA Voltage 90kvp 90kvp 90kvp 80kvp Time 6.3s 6.3s 4.0s 3.2s Power supply Voltage 180-240V Frequency 50Hz Capacity Not over than 7KVA Intemal resistance Not larger than 1ª+ Voltage adjustment range of x-ray tube 50-90KV Range of the time 0.08-6.3s Distance between the focus to the ground 700-1780mm X-ray tube focus transverse rotation í+60íp Specification of x-ray tuble Model XD42.9/100 fixed anode, single focus 1.8/4.3mm Transport dimension(Lí-Wí-H)(mm) 1230í-900í-2050 Weight(kg) Net:159/gross:256. Transport dimension(Lí-Wí-H)(mm) 1230í-900í-2050 Net:159KG Gross:256KG.
X Ray Doors X-ray doors are a common feature in X-ray rooms, as they provide an effective barrier against harmful radiation. The lead lining in these doors is designed to absorb and block the radiation, protecting those outside the X-ray room from exposure. When it comes to choosing lead lined doors for an X-ray room, there are a few key factors to consider. These include: Level of radiation protection required: Depending on the type of X-ray equipment being used and the frequency of use, different levels of radiation protection may be required. Make sure to consult with a radiation safety expert to determine the appropriate level of lead lining for your doors. Door size and configuration: Lead lined doors can be customized to fit a wide range of sizes and configurations, from single doors to double doors and sliding doors. Consider the layout of your X-ray room and the traffic flow when selecting the right door configuration. Material and finish: Lead lined doors can be made from a variety of materials, including wood, steel, and aluminum. Choose a material and finish that meets your aesthetic and durability requirements.
Lead Lined Doors For X Ray Rooms Lead lined doors are a common feature in X-ray rooms, as they provide an effective barrier against harmful radiation. The lead lining in these doors is designed to absorb and block the radiation, protecting those outside the X-ray room from exposure. When it comes to choosing lead lined doors for an X-ray room, there are a few key factors to consider. These include: Level of radiation protection required: Depending on the type of X-ray equipment being used and the frequency of use, different levels of radiation protection may be required. Make sure to consult with a radiation safety expert to determine the appropriate level of lead lining for your doors. Door size and configuration: Lead lined doors can be customized to fit a wide range of sizes and configurations, from single doors to double doors and sliding doors. Consider the layout of your X-ray room and the traffic flow when selecting the right door configuration. Material and finish: Lead lined doors can be made from a variety of materials, including wood, steel, and aluminum. Choose a material and finish that meets your aesthetic and durability requirements. Advantage Lead lined doors are essential for X-ray rooms because they provide a significant advantage in terms of radiation protection. Here are some of the advantages of lead lined doors for X-ray rooms: Radiation Shielding: The primary purpose of lead lined doors is to shield against ionizing radiation, which is harmful to humans. Lead is a dense metal that effectively absorbs radiation and prevents it from escaping the room. This feature is particularly important in X-ray rooms where high levels of radiation are produced. Safety: Lead lined doors are designed to provide a safe working environment for staff and patients in X-ray rooms. The lead lining in the doors prevents radiation from escaping the room, which can be harmful to people working nearby. By using lead lined doors, you can ensure that the radiation stays within the X-ray room, reducing the risk of exposure to others. Regulatory Compliance: The use of lead lined doors is a regulatory requirement in many countries to ensure that X-ray rooms meet the required safety standards. By installing lead lined doors, you can ensure that your X-ray room complies with local regulations and standards. Durability: Lead lined doors are designed to last for many years with minimal maintenance. They are made with high-quality materials that are resistant to wear and tear, ensuring that they provide reliable radiation shielding for an extended period. Cost-Effective: While lead lined doors may be more expensive than regular doors, they are a cost-effective investment in the long run. By providing effective radiation shielding, lead lined doors can help you avoid costly fines, lawsuits, and damage to equipment and facilities.
Medical equipment, medical x-ray machine, digital radiography, b ultrasound scanner.
Ultrasound machine, x-ray machine, lab equipment, dental chair, beauty machine.
Anesthesia machine, ultrasound machine, x-ray machine, dental instrument.
PACS System, ECG Workstation, Ultrasound Image Workstation, Radiation Image Workstation, Endoscope Workstation, CT Image Processing Workstation,, Color Doppler, Patient Monitor, EEG system, ECG system, Transcranial Doppler, Medical X-ray,B ultrasound probe, Medical Monitor, Spo2 sensor, ECG/EKG cable, NIBP cuffs, Probe repair.
Medical x-ray machine, digital radiography, b ultrasound scanner, dental x-ray machine, veterinary equipment, hematology analyzer, ECG.
Ultrasound machine, X-ray machine, dental equipment, autoclaves, ecg, blood analyzer, biochemical analyzer, vet equipment, radiation protection equipment.
Medical equipment: ecg, patient monitor, fetus monitor, ultrasound scanner, x-ray unit, chair mounted dental unit, anaesthesia & ventilator machine.
Medical equipment, lab equipment,ultrasound machine, hearing aid, cpr manikins , x ray, fiber and video endoscopy, ecg&eeg, anesthesia machines, ventilators, hospital furniture , electric surgical unit, operating table, surgical lights, dental chairs and equipment , ophthalmology and ent equipment, first aid equipment , mortuary refrigeration units , medical veterinary equipment ,physiotherapy and rehabilitation device and chinese treatment units.