100mA mobile x-ray machine YSX0410
GENERAL
1. Used in ward and emergency treatment room for radiography.
2. Combined x-ray generator.
3. Single focus, bridge rectification.
4. It is precise safe, reliable and flexible.
5. Remote control device(control rangeí¦5m)is used.
Unit Configuration
Control table, HT generator unit, Ht cable, X-ray tube unit .

Main Characteristics
1. Single table and single tube.
2. Design according to the electric mechanism of middle-size machine ,The function is reasonable.
3. The high-tension system is of march-past structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation.
4. Supply voltage (V), roentgenoscopy, radiography (kv) and stepless adjust able.
5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and portection circuit and KV mA S interlock limitation and protection.
7. Adopt the digial circuit timer, grade according to R10 priority coefficient and can control time exactly.
8. Diagnostic table is of electric back rotation and is equipped with vibrating filter-ray device.
9. The spot film device of luminescent serene can hold the film jecket of various sizes and can make the photography of full-film and two sectional films separateiy.
10. The column has the bottom track only, which is easy while installation.

MIN TECHNICAL INDEXES
X-ray generator : Stationary anode, single focus and bridge silicon rectification.

The x-ray generator is an oil-immersed self-cooled unit.
Max rated capacity
Current
15mA
30mA
60mA
100mA

Voltage
90kvp
90kvp
90kvp
80kvp

Time
6.3s
6.3s
4.0s
3.2s

Power supply
Voltage
180-240V

Frequency
50Hz

Capacity
Not over than 7KVA

Intemal resistance
Not larger than 1ª+

Voltage adjustment range of x-ray tube
50-90KV

Range of the time
0.08-6.3s

Distance between the focus to the ground
700-1780mm

X-ray tube focus transverse rotation
í+60íp

Specification of x-ray tuble
Model XD42.9/100 fixed anode, single focus 1.8/4.3mm

Transport dimension(Lí-Wí-H)(mm)
1230í-900í-2050

Weight(kg)
Net:159/gross:256.



Transport dimension(Lí-Wí-H)(mm)
1230í-900í-2050
Net:159KG
Gross:256KG.