IOMS system is a special design isolated signal remote I/O system, it linked a local area network designed to connect controllers to remote I/O chassis and replacement of discrete wirings by fieldbus or industrial Ethernet communication. MIOS supports up to 31 slots with as many as 128 I/O points in each system. If you need more, you can expand your system with Ethernet router, easily support thousands of I/O points in a single system FEATURES Support universal Input Signal Local area network designed for factory-floor applications Connects controllers to remote I/O chassis and other intelligent devices Channel to channel isolated Remote I/O Built-In Web Server Dual Channel , Power Hot Swap Supported Support Multi Communication Protocols Flexibly Configuration With Sorts of Full Isolated I/O models MWG1 main module support up to 31units I/O modules Back board designed with redundant power-supply interfaces
CP-S Synchroscope indicator show the status of phase difference and frequency difference between two power generator or power system. When the voltage and frequencies in between power generator and network is consistency, rotation of LED Roulette will be slowed down until the SYNC LED is on. Both system can be synchronized and connect the generator to the power network. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance.
CP-W and CP-var analog power meter consists of a moving coil meter with installed transducers which measures the active / reactive power in a sinusoildal or not sinusoidal current circuit and which transformes it into an analogue signal. This is then passed to the moving coil movement. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
General Information Product ID: 3BSE038415R1 Medium Description: AO810V2 Analog Output Module, 8 channels, 0(4)...20mA Technical Information: Supersedes 3BSE008522R1/3BSE038415Z1 Product Type: I/O Module Country of Origin: Estonia /India Customs Tariff Number: 85389091 Length: 102 mm Height: 119 mm Width: 45 mm Weight: 0.19 kg
Description The Trusted 40 Channel Analogue Output or Digital Output FTA is designed to act as the main interface between the Trusted TMR 24V dc Digital Output Module T8451 or Trusted TMR Analogue Output Module T8480 and Trusted the field device. The signal from the output modules are 24V dc and 0-20mA respectively. Features 40 output channels per FTA. Industry standard field device connections (2-wire). Standard DIN rail compatibility. Screw clamp terminals on both field and power. Simple installation and connection. 24V dc operation. SmartSlot connection for one to many hot replacement of output modules. Field power supply arranged in five groups of eight channels, with OV isolation between groups. On-board LED indication field power supply integrity. Field terminal wire size allowance 12 to 28 AWG
Description The Trusted TMR Analogue Output module interfaces to 40 field devices. Triplicated diagnostic tests are performed throughout the module including measurements for current, and voltage on each portion of the voted output channel. Tests are also performed for stuck on and stuck off failures. Fault tolerance is achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40 output channels. Automatic line-monitoring of the field device is provided. This feature enables the module to detect both open and short circuit failures in field wiring and load devices. The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. An output change of state triggers an SOE entry. Output states are automatically determined by voltage and current measurements on board the module. Features 40 Triple Modular Redundant (TMR) output channels per module. Comprehensive, automatic diagnostics and self-test. Automatic line monitoring per point to detect open circuit and short circuit field wiring and load faults. 2500V dc optical isolation barrier. On-board Sequence of Events (SOE) reporting with 1ms resolution. Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot (one spare slot for many modules) configurations. Front panel output status LEDs for each point indicate output status and field wiring faults Front panel module status LEDs indicate module health and operational mode (Active, Standby, Educated) TUV Certified for non-interfering applicatins Outputs are powered in isolated groups of eight
Description The Trusted TMR 24V dc digital input module interfaces to 40 field input devices. A wide input voltage range and programmable thresholds allow the module to be used in current source and current sink configurations. Comprehensive diagnostic tests are performed on each input channel, including tests for stuck on and stuck off failures. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 input channels. When a line-monitoring device is installed at the field switch, the module can detect open and shorted field cables. Line monitoring can be independently configured for each input channel. The module provides on-board sequence of events (SOE) reporting with a resolution of 1ms. A change of state triggers an SOE entry. States are determined by programmable voltage thresholds that can be configured on a per channel basis. When the field voltage and field return are connected to the auxiliary input channels of the module, thresholds can be specified as a ratio of the current field supply voltage. Each triplicated section of the module, referred to as a slice, conditions and measures each channel independently. Each slice is optically isolated up to 2500V dc. Each slice sends its data to a safety layer hardware voter that presents the information from all three slices to the Trusted TMR processor. When a fault is detected on a slice of the module, the Trusted TMR processor will flag the error, indicating the need to replace the module. The Trusted TMR processor will continue to use the information provided by the remaining two slices until a replacement module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly. Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot. Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor. Features 40 TMR input channels per module. Comprehensive diagnostics and self-test. Line monitoring on a per channel basis. 2500V dc optically isolation. On-board 1ms resolution sequence of events reporting. Hot replaceable. Front panel status LEDs for each channel. Module fault and status indicators. IEC 61508, SIL 3 safety applications.
Description The Trusted TMR Analogue Output module interfaces to 40 field devices. Triplicated diagnostic tests are performed throughout the module including measurements for current, and voltage on each portion of the voted output channel. Tests are also performed for stuck on and stuck off failures. Fault tolerance is achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40 output channels. Automatic line-monitoring of the field device is provided. This feature enables the module to detect both open and short circuit failures in field wiring and load devices. The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. An output change of state triggers an SOE entry. Output states are automatically determined by voltage and current measurements on board the module. Features 40 Triple Modular Redundant (TMR) output channels per module. Comprehensive, automatic diagnostics and self-test. Automatic line monitoring per point to detect open circuit and short circuit field wiring and load faults. 2500V dc optical isolation barrier. On-board Sequence of Events (SOE) reporting with 1ms resolution. Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot (one spare slot for many modules) configurations. Front panel output status LEDs for each point indicate output status and field wiring faults Front panel module status LEDs indicate module health and operational mode (Active, Standby, Educated) TUV Certified for non-interfering applicatins Outputs are powered in isolated groups of eight
General Information Product ID: 3BSE052604R1 Medium Description: AI815 Analog Input Module, 8 channels with HART Product Type: I/O Module Country of Origin: India Customs Tariff Number: 85389091 Length: 102 mm Height: 119 mm Width: 45 mm Weight: 0.3 kg
General Information Product ID: 3BSE040662R1 Medium Description: AI830A Analog input Module, 8 channels, RTD Technical Information: Supersedes 3BSE008518R1 Product Type: I/O Module Country of Origin: Estonia /India Customs Tariff Number: 85389091 Length: 102 mm Height: 119 mm Width: 45 mm Weight: 0.3 kg
General Information Product ID: 3BSE045584R1 Medium Description: AO845A Analog Output Module, Redundant or single, 8 channels, HART Technical Information: Supersedes 3BSE023676R1 Product Type: I/O Module Country of Origin: India Customs Tariff Number: 85389091 Length: 102 mm Height: 119 mm Width: 45 mm Weight: 0.3 kg
Description The Trusted Field Termination Assembly (FTA) 24V dc Digital Input T8800 is designed to act as the main interface between a field device generating a digital signal and the Trusted TMR 24V dc Digital Input Module T8403. Features 40 input channels per FTA. Industry standard field device connections (2-wire). Standard DIN rail compatibility. Simple installation and connection. 24V dc operation. SmartSlot connection for one to many hot replacement of input modules. Fused field power supply per channel. On-board LED indication field power supply integrity.
General Information Product ID: 3BSE023675R1 Medium Description: AI845 Analog Input Module, 8 channels, Redundant or single, HART. Product Type: I/O Module Country of Origin: India Customs Tariff Number: 85389091 Length: 102 mm Height: 119 mm Width: 45 mm Weight: 0.34 kg
Description The Trusted TMR 24V dc digital output module interfaces to 40 field output devices. Outputs are arranged in five groups of eight outputs. All outputs in a group share a common power source and return. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 output channels. The module provides on-board sequence of events (SOE) reporting with a resolution of 1ms. The event is the actual sensing of the field device loop current. Each triplicated section (slice) of the module, receives output data from the Trusted TMR processor and sends its data to an internal safety layer hardware voter. Each slice uses the voted data to control the outputs. Every output channel consists of a six-element voted array. The output switch array provides fault tolerant, uninterrupted control under an output switch failure condition. Output switching and fault diagnostics comply with the demanding requirements of IEC-61508 SIL-3 for First fault - Fault tolerant, and Second fault Fail-safe outputs. When a module fault is detected, the Trusted TMR processor will flag the unhealthy condition, indicating the need to replace the module. Control continues until a replacement (healthy) module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly. Each output is user configurable to perform line monitoring of the connected field devices to detect field wiring and load failures. Automatic over-current protection is inherent in every output circuit which eliminates the need for fuses. Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot. Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor. Features 40 TMR output channels per module. Five isolated groups of eight outputs each. Six-element voted output array. Comprehensive diagnostics and self-test. Guaranteed, First fault fault tolerant, Second fault fail-safe. Line monitoring on a per channel basis. Automatic over-current protection no fuses required. 2500V dc optically isolation. Hot replaceable. Front panel status LEDs for each channel. Module fault and status indicators. IEC 61508, SIL 3 safety applications. On-board 1 ms resolution sequence of events reporting.
Description The Trusted TMR 24 / 48V dc Digital Output module interfaces to 40 field devices. Triplicated diagnostic tests are performed throughout the module including measurements for current, and voltage on each portion of the voted output channel. Tests are also performed for stuck on and stuck off failures. Fault tolerance is achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40 output channels. Automatic line-monitoring of the field device is provided. This feature enables the module to detect both open and short circuit failures in field wiring and load devices. The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. An output change of state triggers an SOE entry. Output states are automatically determined by voltage and current measurements on board the module. Features 40 Triple Modular Redundant (TMR) output channels per module. Comprehensive, automatic diagnostics and self-test. Automatic line monitoring per channel to detect open circuit and short circuit field wiring and load faults. 2500V dc optical isolation barrier. Automatic over-current protection (per channel), no fuses required. On-board Sequence of Events (SOE) reporting with 1ms resolution. Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot (one spare slot for many modules) configurations. Front panel output status LEDs for each channel indicate output status and field wiring faults. Front panel module status LEDs indicate module health and operational mode (Active, Standby, Educated) TUV Certified IEC 61508 SIL 3 Outputs are powered in isolated groups of eight. Each power group can be of a different voltage
Description The Trusted TMR analogue input module interfaces to 40 single-ended field input devices. A wide input range and programmable thresholds allow the module to be used in most voltage or current configurations. Comprehensive diagnostic tests are performed on each input channel, including tests for out of range values and stuck at failures. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 input channels. The module can apply a digital filter to each input channel. Individual channels can be configured for high noise immunity (50Hz or 60Hz rejection), low noise immunity (fast response) or pass-through operation (no filtering). Each input channel has four configurable state thresholds, which may be assigned to SOE reporting. A change of state triggers an SOE entry. The on-board sequence of events (SOE) reporting has a resolution of 1ms. Each triplicated section of the module, referred to as a slice, conditions and measures each channel independently. Each slice is optically isolated up to 2500V dc. Each slice sends its data to a safety layer hardware voter that presents the information from all three slices to the Trusted TMR processor. When a fault is detected on a slice of the module, the Trusted TMR processor will flag the error, indicating the need to replace the module. The Trusted TMR processor will continue to use the information provided by the remaining two slices until a replacement module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly. Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot. Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor. Features 40 TMR input channels per module. Comprehensive diagnostics and self-test. 2500V dc optically isolation. Digital signal filtering on a per channel basis. Four user configurable thresholds per channel. On-board 1ms resolution sequence of events reporting. Hot replaceable. Front panel status LEDs for each channel. Module fault and status indicators. IEC 61508, SIL 3 safety applications.
Description The Trusted 40 Channel Analogue Input FTA T8830 is designed to act as the main interface between a field device generating an analogue signal and the Trusted TMR Analogue Input Module T8431. Features 40 input channels per FTA. Industry standard field device connections (2-wire). Standard DIN rail compatibility. Simple installation and connection. 24V dc operation. SmartSlot connection for one to many hot replacement of input modules. Fused field power supply per channel. On-board LED indication field power supply integrity.
General Information Product ID: 3BSE051306R1 Medium Description: AI835A Analog input Module, 8 channels, thermocouple/mV Technical Information: Supersedes 3BSE008520R1/3BSE008520Z1/ 3BSE051306Z1 Product Type: I/O Module Country of Origin: Estonia Customs Tariff Number: 85389091 Length: 150 mm Height: 150 mm Width: 75 mm Weight: 0.2 kg
General Information Product ID: 3BSE028925R1 Medium Description: AI843 Analog Input Module, 8 channels, Redundant or Single, thermocouple /mV Product Type: I/O Module Country of Origin: Estonia Customs Tariff Number: 85389091 Length: 102 mm Height: 119 mm Width: 45 mm Weight: 0.25 kg
General Information Product ID: 3BSE052605R1 Medium Description: AO815 Analog Output Module, 8 channels with HART Product Type: I/O Module Country of Origin: India Customs Tariff Number: 85389091 Length: 102 mm Height: 119 mm Width: 45 mm Weight: 0.3 kg