XX- line of portable X-ray units is designed to the principle of low cost and high reliability, which is characteristic in convenient to carry, easy to operate, and highly automated. X-ray tube and HT coil are all produced by DANDONG NDT which guarantees system consistency. Weight is further reduced with the use of SF6 insulation. Forced cooling fan guarantee the longevity of X-ray tube, which makes the product suitable for field and highly above work. K03/K05 control unit is microprocessor controlled with module of controlled silicon voltage adjustment and frequency conversion. The functions of fully automatic warm-up program, fault display, over voltage and mis-start protection, the stability and service life are much improved. 655 ¬200mm 15kg
NDT X ray equipment is used for inspect the inner fault of the material. It adopts radiography theory to make the image on the film, in order to evaluate the work piece. Features of X Ray Generator: Adopt high temperature installation technology and high pure degree aluminum radiator to improve 30% heat radiation. Portable design, light weight and easy operation. SF6 gas insulator, grounded-anode design to keep the operator safety. Strictly follow 1:1 work and rest radio, eliminating the disoperation. Good HV coil made by imported enamel wire in the generator to improve the power. Glass tube Panoramic XXH-1005 Power(KW) >1.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 6 XXH-1605 Power(KW) >1.5 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 18 XXH-2005 Power(KW) >2.0 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 26 XXH-2505 Power(KW) >2.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 36 XXH-3005 Power(KW) >3.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 46 XXH-3505 Power(KW) >3.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 56 Glass tube Directional XXQ-1005 Power(KW) >1.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 8 XXQ-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXQ-2005 Power(KW) >2.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) :29 XXQ-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXQ-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXQ-3505 Power(KW) >3.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 59 Ceramic tube directional XXG-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXG-2005 Power(KW) >2.0 , Beam Angle: 40, Max.Penetration A3 steel (mm) : 29 XXG-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXG-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXG-3505 Power(KW) >3.5 , Beam Angle: 40°, Max.Penetration A3 steel (mm) : 59 wooden case 80KG
The main products of our company are composed of X -ray tube, portable X -ray flaw detection machine, mobile X -ray flaw detection machine, X -ray orientation equipment and X -ray diffraction equipment, among which X -ray instrument amounts to 43 varieties, and X -ray tube amounts to 67 varieties. The X-ray tube products including 10kv-350kv each kind of specification, specially uses in the fluorescence spectroscope's X- ray tube, in the mobile flaw detection machine the ceramic X- ray tube achieving the international advanced level. We have produced the 160kv, 2mA X- ray tube used in security check for more than 20 years, product best-selling the world. Wooden case.
Power supplyAc 198v-242v 50-60hz Power (kva)3.5 Tube current (ma)5 Tube voltage (kv)150-250 Focal spot (mm)2.0 x 2.0 Radiacation coverage40o CoolingAir Weight (kg)X-ray generator29 Control unit13 Size (mm)X-ray generator270 x 270 x 700 Control unit320 x 180 x 380 Max penetration fe(mm)39
Place of origin liaoning, china (mainland) Brand name dgt Model number xxg-3005 Power electronic Usage non-destructive testing Nature x-ray Business mancfacturer Function non-destructive testing fields X-ray tube ceramic tube Focus size(mm) 2.5*2.5 Weight of generator 34kg Dimension of generator 320*320*625 Max penetration(mm) 50mm Payment & shipping terms: Fob price: us $ 6, 000-8, 000/ set Get latest price Minimum order quantity: 1 set/sets Port: dalian Packaging details: wooden cases Delivery time: 10 in working days Payment terms: t/t Supply ability: 20 set/sets per month
The portable series gas insulation x-ray flaw detector can be widely used in shipbuilding, Chemistry, aviation, boiler, pressure container, national defense industry for ndt flaw detection. It absorbs different lever of x-ray based on the different thickness of materials. From the x-ray Perspective negative, we can see the faults of materials, parts as well as interior of weld joint. According to the fault shape, degree and position, we can confirm the quality of materials and Products. The portable x-ray flaw detectors are divided into two series: directional radiation flaw Detection and round radiation flaw detection. Round radiation is efficiently used in circle weld Joint, matched with the ribbon shape negative, the labor force can be reduced and the working Efficiency be increased greatly. Portable x-ray unit(xxg-3005) X-ray tube voltage 170-300kv X-ray tube current 5ma Focus spot size; 2.5*2.5mm Max. Penetration- a3 steel 50mm(5min exposal, d>=1.5) Tube voltage stability +-5% Tube current stability +-5% Generator external size 330*330*700mm Generator weight: 40kg Controller size: 390*380*170mm (including handle) Controller weight: 12kg Input power: 220v+-10%;ac 50hz, capability>=3.6kva Operating temperature: -20~+40
X ray tube technology parameters  Testing equipment using x ray tube Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links. mode Tube voltage Tube current spots Filament voltage ThefilamentcurrentRadiation Angle (KVp) (mA) (mm) (V) (A) (°) The length of the XA33A 160 2 0.8* 0.8 5.3 4.4 40°+5° 68mm190mm XA33B 160 4 0.3*0.8 4 3.5±0.2 110°�40° 68mm190mm XA33C 160 4 2.5*0.8 3.5±0.2 3.7±0.2 110°�20° 68mm190mm XA33D 160 2 0.8* 0.8 3.5±0.2 3.70±0.2 80°�60° 68mm190mm XA33E 160 4 0.8*0.8 3.5±0.2 3.7±0.2 60° 68mm190mm XA33F 160 5 0.8*0.8 3.5±0.2 3.7±0.2 40°�60° 68mm190mm XA33G 200 3 1.5*1.5 4.6±0.2 3.4±0.2 80°�60° 211mm XA36H 100 1.4 0.6�0.6 5±0.2 2.1±0.2 40°�60° ���mm
X ray tube technology parameters Testing equipment using x ray tube Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links. specifications Tube Tube Filament The filament spots size voltage current voltage current �KV) �mA) (V) (A) (mm) (mm) XA-801 80 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-801A 80 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-1001 100 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-1001A 100 1.5 5±0.5 2.1 0.8*0.8 116±1 XA-1402 140 2.5 5±0.5 4 0.8*0.8 190±2 XA-1402A 140 2.5 5±0.5 4 0.8*0.8 190±2 XA-1602A 160 2.5 5±0.5 4 0.5*0.5 190±2 XA-2003 200 2.5 5±0.2 4 1.5*1.5 211±1
X ray tube technology parameters  Testing equipment using x ray tube Mainly used for application in the heat, pressure vessel, aviation, aerospace, electric power, petroleum, chemical, pipeline, military industry, nuclear industry, shipbuilding, automobile, metallurgy, steel structure, railway, university, luggage and parcel safe industries such as manufacturing, production, quality control links.  mode Tube voltage Tube current spots Filament Thefilame Radiation Angle voltage ntcurrent (KVp) (mA) (mm) (V) (A) (°) XA33A 160 2 0.8* 0.8 5.3 4.4 40°+5° XA33B 160 4 0.3*0.8 4 3.5±0.2 110°�40° XA33C 160 4 2.5*0.8 3.5±0.2 3.7±0.2 110°�20° XA33D 160 2 0.8* 0.8 3.5±0.2 3.70±0.2 80°�60° XA33E 160 4 0.8*0.8 3.5±0.2 3.7±0.2 60° XA33F 160 5 0.8*0.8 3.5±0.2 3.7±0.2 40°�60° XA33G 200 3 1.5*1.5 4.6±0.2 3.4±0.2 80°�60° XA36H 100 1.4 0.6�0.6 5±0.2 2.1±0.2 40°�60°
Product Model: XXQ-2505 Output Voltage (KV): 150-250 Input (KW): 2.5 Focus Spot (mm): 2.0,2.0 Beam Angle: 40 +5 Max Penetration (mm): 39 (Steel A3) Weight (kg): Generator: 37 Controller: 20 Dimensions (mm): Generator: 320,730 Controller: 365,310,225. * Compact X-ray generator, anode grounded, forced air cooling * Light weight, portable, easy to use * The radio of the exposure time to the stop time is 1:1 * Aging the X-ray generator and checking the exposure parameter automatically * High-voltage time-delay function protects the operator from radiation * Strictly controlled the production technique, nice outward, reasonable designing. Wooden cases, and two cases for one set of x-ray equipment.
Our company produce and supply Industrial X-ray Equipment, X-ray Tube, X-ray Flaw Detector; Medical X-ray Tube; X-ray Tube for security check; and X-ray Pipeline Crawler. Features of X-ray Equipment: Compact X-ray generator, anode grounded, forced air cooling; Light weight, portable, easy to use; The radio of the exposure time to the stop time is 1:1; Aging the X-ray generator and checking the exposure parameter automatically; High-voltage time-delay function protects the operator from radiation; Strictly controlled the production technique, nice outward, reasonable designing. Wooden cases, and two cases for one set of x-ray equipment.
X-ray digital imaging system (dr - digital radiograph) by imaging, x-ray machine, the x-ray machine synchronous control unit, with the highest detection sensitivity of the high-tech equipment. All digital radiographic testing standard, including welding, casting, corrosion testing standards, including metal, nonmetal and composite materials testing a variety of purposes, such as widely used in aviation, spaceflight, automobile, electric power, petroleum, chemical industry, pharmacy, special inspection, etc. High reliability, long life, low failure rate, high resolution, high resolution detector humanized design software, the interface is simple, easy to operate, according to the test requirements, develop software functions X-ray real-time imaging cylinder welding seam detection Scope of application and main technical parameter 1 main application: used in cylinders and all kinds of metal materials internal welding defects, such as blow hole, shrinkage cavity, porosity, crack, weld defects, etc. 2�checked the product size: Size: 100-800 - mm diameter or less;height 600-2200 - mm or less 3�the x-ray flaw detecting closed refrigeration, has forced cooling, the flow protection, temperature protection and self protection tube temperature 40 ?? or less and the capacity to ensure that equipment work continuously. 59 "x-ray real-time imaging system (xsc9b) or varian1313 flat-panel detector.
Refractory x-ray real-time imaging detection Scope of application and main technical parameter 1 main application: used for refractory material: 3 big casting, refractory brick etc. Nonmetal and internal defects of all kinds of metal material, such as blow hole, shrinkage cavity, porosity, crack, weld defects, etc. 2.checked the product size: Width: ?¤500 mm , height?¤ 600-2000 - mm 3 the x-ray flaw detection machine capacity: 350 kv, 5 ma 4 cooling method: using closed refrigeration, has forced cooling, the flow protection, temperature protection and self protection tube temperature 40 ?? or less and the capacity to ensure that equipment work continuously. 59 "x-ray real-time imaging system (xsc9b type) 6the system sensitivity: dynamic sensitivity is better than 2.2%, the static sensitivity is better than that of 1.2% ~ 1.6%. 7 the system resolution: 16 ~ 24 lp/cm 8 for x ray films and real-time imaging shows two ways of working.
X-ray digital imaging system (dr - digital radiograph) by imaging, x-ray machine, the x-ray machine synchronous control unit, with the highest detection sensitivity of the high-tech equipment. All digital radiographic testing standard, including welding, casting, corrosion testing standards, including metal, nonmetal and composite materials testing a variety of purposes, such as widely used in aviation, spaceflight, automobile, electric power, petroleum, chemical industry, pharmacy, special inspection, etc. High reliability, long life, low failure rate, high resolution, high resolution detector humanized design software, the interface is simple, easy to operate, according to the test requirements, develop software functions X-ray real-time imaging cylinder welding seam detection Scope of application and main technical parameter 1ã?� main application: used in cylinders and all kinds of metal materials internal welding defects, such as blow hole, shrinkage cavity, porosity, crack, weld defects, etc. 2ã?�â checked the product size: Size: 100-800 - mm diameter or less;height 600-2200 - mm or less 3ã?�â the x-ray flaw detection machine capacity: 225 kv, 8 ma 4ã?�â cooling method: using closed refrigeration, has forced cooling, the flow protection, temperature protection and self protection tube temperature 40 â?? or less and the capacity to ensure that equipment work continuously. 5ã?�9 "x-ray real-time imaging system (xsc9b) or varian1313 flat-panel detector.
Our company produce and supply Industrial X-ray Equipment, X-ray Tube, X-ray Flaw Detector; Medical X-ray Tube; X-ray Tube for security check; and X-ray Pipeline Crawler. Features of X-ray Equipment: Compact X-ray generator, anode grounded, forced air cooling; Light weight, portable, easy to use; The radio of the exposure time to the stop time is 1:1; Aging the X-ray generator and checking the exposure parameter automatically; High-voltage time-delay function protects the operator from radiation; Strictly controlled the production technique, nice outward, reasonable designing. Wooden cases, and two cases for one set of x-ray equipment.
Items Parameters Model : XXQ-3505 Max. Penetration A3 Steel : 60 mm Exposure Time : 5 minutes Film Type : T3 Developing Time : 5 minutes Blackening : 1.5 Sensitivity : 1.8% Input Voltage : AC198-240V/50Hz (60Hz) Capacity : 3.5 kVA Ambient Temperature : -30~40 Ambient Humidity :85% X-ray Tube material : glass X-ray Tube Emission : Directional Focal Size : 2.52.5mm Radiation Angle : 40 ° Output Voltage : 180-350kV Output Current : 5mA X-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34Mpa 0.45MPa X-ray Generator Dimension D345*H830 mm X-ray Generator Weight 48 Kg Controller Dimension 350290150mm Controller Weight 10Kg
Items Parameters Model :XXGH-3005 Max. Penetration A3 Steel : 47 mm Focal Length : 600 mm Exposure Time :5 minutes Film Type : T3 Operation Temperature in Darkroom : 20 Developing Time :5 minutes Blackening : 1.5 Sensitivity : 1.8% Input Voltage :AC198-240V/50Hz (60Hz) Capacity :3.5 kVA Ambient Temperature :-30~40 Ambient Humidity : 85% X-ray Tube material :ceramic X-ray Tube Emission :Panoramic Focal Size :1.02.5mm Radiation Angle : 360 ° * 25° Output Voltage :170-300kV Output Current : 5mA X-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34MPa0.45MPa X-ray Generator Dimension : D320*H630 mm X-ray Generator Weight : 34 Kg Controller Dimension : 350290150mm Controller Weight :10Kg
YG-100A1 X-ray pipeline crawler No Items Parameter Remarks 1 Operational Pipe DN700-DN1400 2 Max. Penetration 42mm A3 Steel 3 Max. Output Voltage 300Kv 0~5 Steps Shift 4 Max. Output Current 3mA 5 Focus 1.0Ã?2.5mm Beam Angel 360°Ã?30° 6 Working Temperature ï¼?40°~ 70° 7 Relative Humidity â?¤90% 8 Capacity of Battery 110V, 22Ah Lead acid battery 9 Motor Power 250W Continuous Rare earth motor 10 Exposure Delay 24s Safety time for distance 11 Exposure Duration 1~300sï¼?Continuously variableï¼?Set by Touching LCD 12 Slope Ability Two-wheel driveï¼?â?¤27° Four-wheel driveï¼?Manual):â?¤40° Optional 13 Positioning error ±5mm 14 Proceeding Distance 5Km Round-trip 15 Proceeding Speed 15m/min~18m/min 16 Turning Radius â?¥7D Curve in pipeline 17 Weight Body 50.5Kg Total117.5Kg Excluding Generator and batteries Batteries 67 Kg Power unit of crawler Generator 34Kg Component generating x-rays Commander 2.8Kg Positioning device 18 Outline Dimension Crawler 1.2Ã?0.38Ã?0.1 9m Generator Φ274Ã?765 mm XXH-300ï¼?Panoramic Coneï¼? 19 Commander Outlineï¼? 255Ã?113Ã?155 mm Positioning device(12 hours enduranceï¼? Max. Penetration Thickness: 34mm
Items Parameters Model :XXGH-3005 Max. Penetration ï¼?A3 Steelï¼? : 47 mm Focal Length : 600 mm Exposure Time :5 minutes Film Type : T3 Operation Temperature in Darkroom : 20±2 Developing Time :5 minutes Blackening : 1.5 Sensitivity : 1.8% Input Voltage :AC198-240V/50Hz (60Hz) Capacity :3.5 kVA Ambient Temperature :-30~40 Ambient Humidity : 85% X-ray Tube material :ceramic X-ray Tube Emission :Panoramic Focal Size :1.02.5mm Radiation Angle : 360 º*25° Output Voltage :170-300kV (±2%) Output Current : 5mA (±2%) X-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34MPa0.45MPa X-ray Generator Dimension : D320*H630 mm X-ray Generator Weight : 34 Kg Controller Dimension : 350290150mm Controller Weight :10Kg
Items Parameters Model : XXQ-3505 Max. Penetration A3 Steel : 60 mm Exposure Time : 5 minutes Film Type : T3 Developing Time : 5 minutes Blackening : 1.5 Sensitivity : 1.8% Input Voltage : AC198-240V/50Hz (60Hz) Capacity : 3.5 kVA Ambient Temperature : -30~40 Ambient Humidity :85% X-ray Tube material : glass X-ray Tube Emission : Directional Focal Size : 2.52.5mm Radiation Angle : 40 º±5° Output Voltage : 180-350kV (±2%) Output Current : 5mA (±2%) X-ray Generator Cooling : Fan Insulation : SF6 Pressure Gauge : 0.34Mpa 0.45MPa X-ray Generator Dimension D345*H830 mm X-ray Generator Weight 48 Kg Controller Dimension 350290150mm Controller Weight 10Kg