XX- line of portable X-ray units is designed to the principle of low cost and high reliability, which is characteristic in convenient to carry, easy to operate, and highly automated. X-ray tube and HT coil are all produced by DANDONG NDT which guarantees system consistency. Weight is further reduced with the use of SF6 insulation. Forced cooling fan guarantee the longevity of X-ray tube, which makes the product suitable for field and highly above work. K03/K05 control unit is microprocessor controlled with module of controlled silicon voltage adjustment and frequency conversion. The functions of fully automatic warm-up program, fault display, over voltage and mis-start protection, the stability and service life are much improved. 655 ¬200mm 15kg
Technical data: Oxygen flow:0.5-5L/min Oxygen concentration:95.5%-87% Output pressure: 40-70kPa Pressure relief mechanism operational at: 250kPa + 25kPa Operation nose Level
Oxygen Concentrator - 0.5-10L/Min Purityï¼? 96% Compressor Life - 25000hours Sound Level 60dB Screen - LED Segment real-time display Power comsumption - 500VA Net Weight - 23k Gross weight:27kg
Fuel LPG. Fuel Tank Capacity 2.0 L Fuel Consumption : App. 225 g P/H Length : 350 mm Height : 330 mm Width : 150 mm Weight(kg) Empty : 1.5 Kg (Empty)
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance