NDT X ray equipment is used for inspect the inner fault of the material. It adopts radiography theory to make the image on the film, in order to evaluate the work piece. Features of X Ray Generator: Adopt high temperature installation technology and high pure degree aluminum radiator to improve 30% heat radiation. Portable design, light weight and easy operation. SF6 gas insulator, grounded-anode design to keep the operator safety. Strictly follow 1:1 work and rest radio, eliminating the disoperation. Good HV coil made by imported enamel wire in the generator to improve the power. Glass tube Panoramic XXH-1005 Power(KW) >1.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 6 XXH-1605 Power(KW) >1.5 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 18 XXH-2005 Power(KW) >2.0 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 26 XXH-2505 Power(KW) >2.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 36 XXH-3005 Power(KW) >3.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 46 XXH-3505 Power(KW) >3.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 56 Glass tube Directional XXQ-1005 Power(KW) >1.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 8 XXQ-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXQ-2005 Power(KW) >2.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) :29 XXQ-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXQ-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXQ-3505 Power(KW) >3.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 59 Ceramic tube directional XXG-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXG-2005 Power(KW) >2.0 , Beam Angle: 40, Max.Penetration A3 steel (mm) : 29 XXG-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXG-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXG-3505 Power(KW) >3.5 , Beam Angle: 40°, Max.Penetration A3 steel (mm) : 59 wooden case 80KG
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
The portable series gas insulation x-ray flaw detector can be widely used in shipbuilding, Chemistry, aviation, boiler, pressure container, national defense industry for ndt flaw detection. It absorbs different lever of x-ray based on the different thickness of materials. From the x-ray Perspective negative, we can see the faults of materials, parts as well as interior of weld joint. According to the fault shape, degree and position, we can confirm the quality of materials and Products. The portable x-ray flaw detectors are divided into two series: directional radiation flaw Detection and round radiation flaw detection. Round radiation is efficiently used in circle weld Joint, matched with the ribbon shape negative, the labor force can be reduced and the working Efficiency be increased greatly. Portable x-ray unit(xxg-3005) X-ray tube voltage 170-300kv X-ray tube current 5ma Focus spot size; 2.5*2.5mm Max. Penetration- a3 steel 50mm(5min exposal, d>=1.5) Tube voltage stability +-5% Tube current stability +-5% Generator external size 330*330*700mm Generator weight: 40kg Controller size: 390*380*170mm (including handle) Controller weight: 12kg Input power: 220v+-10%;ac 50hz, capability>=3.6kva Operating temperature: -20~+40
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
Brand New Ge Make Portable 20 Ma X Ray Machine For Sale With Tube Head Anmd Console .(fully Refurbished Equipment)